WattMaster CommLink IV Manual de usuario

CommLink IV
Setup Guide
www.wattmaster.com
STATUS
www.wattmaster.com
RX-USB
TX-USB
COMM
TX-CPU
RX-CPU
ACT-LAN
LNK-LAN
CONTROLS
CommLink IV

Table of Contents
WattMaster Controls, Inc.
8500 NW River Park Drive · Parkville, MO 64152
Toll Free Phone: 866-918-1100
PH: (816) 505-1100 · FAX: (816) 505-1101 · E-mail: mail@wattmaster.com
Visit our web site at www.wattmaster.com
Form: WM-CMLKIV-INST-01A Copyright 2008 WattMaster Controls, Inc.
WattMaster Controls, Inc. assumes no responsibility for errors or omissions.
This document is subject to change without notice.
General Information......................................................................................................................................... 3
CommLink IV Overview................................................................................................................................................................3
Optional IP Module Kit..................................................................................................................................................................3
Optional Remote Link...................................................................................................................................................................3
Installing CommLink IV ONLY ......................................................................................................................................................3
System Requirements..................................................................................................................................................................3
Connection and Wiring .................................................................................................................................... 4
Communication Settings ................................................................................................................................. 5
CommLink IV USB Driver Installation Instructions ........................................................................................ 6
USB Serial Converter Software Installation..................................................................................................................................6
USB Serial Port Software Installation...........................................................................................................................................7
Finding what COM Port # the CommLink IV is Using...................................................................................................................8
Changing the USB Serial COM Port Number...............................................................................................................................9
Prism USB Driver Installation Instructions ................................................................................................... 10
CommLink IV LED Descriptions .................................................................................................................... 12
Connecting the Network ............................................................................................................................... 13
Proxy and Firewall Compatibility ................................................................................................................................................13
Troubleshooting ............................................................................................................................................. 14
Troubleshooting Procedures ......................................................................................................................................................14

CommLink IV Setup Guide
3
Operator Interface
CommLink IV Overview
The CommLink IV is used to transfer communications between
controllers on your control system loops. It can also be used as
an interface for connection of a computer to your system.
The CommLink IV provides communication with the control
system through any computer that is running Prism software.
For remote communications, an IP Module Kit can be installed
for LAN and Internet connections or a Remote Link can be con-
nected for dial-up connections.
Optional IP Module Kit
The OE415-02 IP Module Kit, when installed and congured in
the CommLink IV communication interface, provides TCP/IP
Internet and/or intranet connection for Ethernet networked com-
puter systems allowing them to communicate with your control
system. The OE415-02 IP Module Kit consists of the IP Module
and a 10 ft. long CAT5 Ethernet crossover cable.
Using standard TCP/IP Protocol, with WattMaster’s Prism soft-
ware, you are able to monitor and congure your controllers
without a modem or a direct connection from a PC. Utilizing
existing routers, proxies, or rewalls allows a PC running Prism
to connect to a controller in a remote accessible location or build-
ing. Several IP connection proles can be created to facilitate
monitoring several CommLink IVs with IP Module Kits installed
on individual sites.
Optional Remote Link
The OE-419-06 Remote Link is a 14,400 baud modem that can
be used with a CommLink IV or a computer. It is used to provide
remote dial-up communications with the CommLink IV. When it
is used as a computer modem (at the remote computer location),
it connects to the remote computer.
NOTE: WattMaster will not support any other internal or
external modems by other manufacturers.
The Remote Link connects to the CommLink IV communications
interface at the control system location via a DB9 serial cable.
A telephone line connects the Remote Link to the local phone
service. Connection is made by dialing the telephone number
of the job site where the Remote Link is located. Using another
Remote Link modem connected to a computer at a remote loca-
tion, the control system can be monitored and controlled using
the Prism computer front end software package.
Installing CommLink IV ONLY
When you are using the CommLink IV in an application without
a computer, Remote Link, or IP Link Module, wire the RS-485
loop terminal to a MiniLink, MiniLink PD, or other controller on
your controls loop as required by your specic system.
Connect the power pack to a 110 volt wall outlet and connect
its wires to the power terminal block on the CommLink IV. If
desired, a 24 vac transformer rated at 12 VA minimum may be
used instead of the supplied power pack. Use 18 gauge minimum
2 conductor wire between the transformer and CommLink IV
terminals. Set the dip switch on the CommLink IV as shown in
Figure 2.
System Requirements
To program the CommLink IV to work with Prism, you will
need:
Standard Items (Required)
• CommLink IV with power adapter
• A PC with an Ethernet communications port or USB
port (supplied by others)
• Microsoft Windows 98, NT, 2000, XP, or Vista
(must be installed on the PC you are going to use)
• Prism software CD (ordered separately from
WattMaster)
Optional Items
• CommLink IP Module that comes with
Ethernet RJ-45 Crossover CAT 5, 10 ft. long cable for
LAN, and Internet remote communications
• Remote Link that comes with connection
cables for dial up remote communications
General Information

CommLink IV Setup Guide
4Operator Interface
Connection and Wiring
Figure 1: CommLink IV Connection & Wiring

CommLink IV Setup Guide
5
Operator Interface
Communication Settings
Figure 2: CommLink IV Communication Settings

CommLink IV Setup Guide
6Operator Interface
CommLink IV USB Driver Installation Instructions
You must follow the included CommLink IV Communications
Interface connection and wiring instructions sheet to connect and
congure the CommLink IV before beginning the USB driver
installation procedure.
USB Serial Converter
Software Installation
CAUTION: You must use the drivers on the CD-ROM
supplied with the CommLink IV. DO NOT
download drivers from the FTDI website,
because these will not work for the
CommLink IV Communication Interface!
1. Insert the CommLink IV CD-ROM into your CD-
ROM drive.
2. Apply power to the CommLink IV if it is not powered
up already.
3. A message should pop up from the Tool bar that
reads, “Found New Hardware.” Click on the Found
New Hardware Wizard application from the Tool
Bar.
4. The window that appears will ask the question, “Can
Windows connect to Windows Update to search for
software?” as shown below. Select “No, not this time”
and click <Next>.
5. The next window that appears asks, “What do you
want the wizard to do?” Select “Install from a list or
specic location (Advanced)” as shown below and
click <Next>.
6. On the next window as shown below make sure
that “Search for the best driver in these locations” is
selected. Uncheck the box that reads, “Search remov-
able media” and instead check the box “Include this
location in the search:”
7. Click <Browse> and locate the drive that your CD-
ROM is located on. Click <Next>.

CommLink IV Setup Guide
7
Operator Interface
8. The next window will search and nd the les it
needs to download and will start downloading them
as shown below.
9. While the les are downloading, a Hardware Instal-
lation window might pop up as shown below. Click
<Continue Anyway>.
10. The wizard will then nish installing the software.
11. Once the wizard is done, click <Finish>.
USB Serial Port Software Installation
1. Once the Serial Converter software is installed, the
Found New Hardware Wizard will appear again to
download the USB Serial Port software.
2. Follow steps 1 though 7 of the previously described
USB Serial Converter Installation instructions.
3. Click <Finish> when the wizard is done download-
ing the software.
4. WinXP requires you to restart your computer before
new settings will take effect.
CommLink IV USB Driver Installation Instructions

CommLink IV Setup Guide
8Operator Interface
Finding What COM Port # the
CommLink IV is Using
1. Left-click on <Start>, located on the bottom left of
the Windows Tool Bar.
2. Select <Control Panel>.
3. Double-click the System Icon.
4. Click the <Hardware> tab.
5. Click the <Device Manager> button.
6. Click on the plus sign next to Ports to see all of the
common ports.
7. Locate the USB Serial Port (COM#). The COM# in
parentheses is the port it is located on. Write this com
port number down. You will need to know this when
setting up the Prism software.
CommLink IV USB Driver Installation Instructions

CommLink IV Setup Guide
9
Operator Interface
CommLink IV USB Driver Installation Instructions
Changing the USB Serial COM Port
Number
When the CommLink IV is rst plugged in, it will be assigned
a COM Port Number to be used for communicating with the
Prism software. If the port number is higher than 9, it needs to be
changed to a value less than 9 to be recognized by Prism. Follow
the steps below to do this.
1. Click <Start>, click <Control Panel>, click
<System>, and then click the <Hardware> tab
and then click <Device Manager> to get to the
Device Manager Window.
2. Click on the plus sign next to Ports to see all of the
common ports.
3. Right-click on “USB Serial Port (COM#)” and select
<Properties>. In the Properties Window, select the
<Port Settings> tab.
4. Change the Bits per Second (Baud Rate) to 19200.
Then click on <Advanced>.
5. In the COM Port Number drop box, select which
COMM Port you wish to use. Be sure you do not
select a COM number that is already in use. Select a
port that is less than 10.
6. Once you select the correct COM Port Number, click
<OK> and close any windows opened in the process
of changing the port number.

CommLink IV Setup Guide
10 Operator Interface
Prism USB Driver Installation Instructions
Setting Up Prism
1. Open your Prism software.
2. Click on the Key button and type in the
password “sm”.
3. Click <Done>.
4. If Prism is online, click <Communications> and
then click <Go Ofine>.
5. Click on the Edit Jobsite button to enter
jobsite information.
6. Click on an empty location. Type in a job name and
press <Enter>.
7. Double-click in the Port location on the same line as
the job name. The PortCtl Class Properties Window
will pop up.
8. Click on the down arrow on the Port pull down box
and select the Comm. Port # that the CommLink IV
is using. This port number is the one you should have
found in the Device Manager previously. Click
<Apply> and then click <OK>.
9. If you are using a Single Version CommLink, type a
“1” in the CommLink eld in the Job Site Window
and press <Enter>. For all other congurations,
leave “0” in the eld.
10. Click <Done>.
11. Click <Communications> again and select <Go
OnLine>.
12. Click <Communications> again and select
<Search for Units>.
Otros manuales para CommLink IV
2
Tabla de contenidos
Manuales populares de Sistema de conferencias de otras marcas

Kramer
Kramer VIA GO Manual de usuario

AVT
AVT MAGIC AC1 Go Manual de usuario

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manual de usuario

Sony
Sony PCS-I150 Manual de usuario

Middle Atlantic Products
Middle Atlantic Products VTC Series Manual de usuario

Prentke Romich Company
Prentke Romich Company Vanguard Plus Guía