56;,! ;OPZ WVZP[PVU PZ
UV[ H]HPSHISL VU >H`
4\S[PWVY[=HS]LZ
0WN
4\S[P*`JSVUL
OPTIONAL MOUNTING STAND [200373]
An optional Mounting Stand is also available for situations where the MultiCyclone cannot be
installed directly above your pool pump.
Installation with optional Mounting Stand
FILTER MAINTENANCE
Filter maintenance determined by the following conditions:
1. The ow rate through the MultiCyclone is insufcient to meet the demand.
2. The sediment chamber is half lled with sediment.
The accumulation of sediment can be visibly monitored through the MultiCyclone’s clear
sediment chamber. The MultiCyclone is cleaned by simply opening the purge valve. Only 15
litres [4 gallons] of water is discharged to clean the MultiCyclone of sediment.
FLUSHING OUT THE SEDIMENT CHAMBER
With pump running
Whilst the water pump is running simply open the sediment purge valve until the sediment has
been ushed out. This is visible through the clear sediment chamber. Once the sediment has
been ushed out, close the sediment purge valve.
Without pump running
Alternatively, switch the pump, off. Open the air release valve and open the sediment purge valve
until the sediment has been ushed out. This is visible through the clear sediment chamber.
Once the sediment has been ushed out, close the sediment purge valve.
The closed valve increases the ow of water through the sediment chamber, improving the
purging action of the MultiCyclone.
Whist the pump is not operating close the 2 way shut off valve and open the purge valve. Switch
on the pump to purge the sediment chamber of its sediment. Once the sediment chamber is
purged, switch off the pump and open the 2 way shut off valve and close the purge valve.
Installation with 2 way shut off valve
WINTERISING
Proper winterising procedures should always be taken in order to protect your lter in cold
climates [temperatures below freezing point]
1. Switch off the Pump / Close the Inlet Valve,
2. Open the air release valve and open the purge valve.
3. Drain all water from the pipework.
WARRANTY
MultiCyclone is covered by a 2 warranty.
For more information please refer to the Waterco “Warranty Terms & Conditions” booklet.
INSUFFICIENT WATER PRESSURE
In situations where your water pump is not powerful enough to force the sediment out of the
sediment chamber. Waterco recommends tting a 2 way shut off valve between the MultiCyclone
and the lter. The shut off valve is closed off whilst you are purging the sediment chamber.
Operation of the Multiport Valve or mode selection is to be always done with the pump switched off.
If the MultiCyclone is installed as a pre-lter to a sand lter, water ow to the sand lter can be
closed via the sand lter’s multiport valve.*