CONTENTS
1. PRECAUTIONS ....................................................................................................... - 1 -
2. INTRODUCTION ..................................................................................................... - 2 -
3. INSTALLATION ........................................................................................................ - 3 -
3.1 Unpacking ....................................................................................................... - 3 -
3.2 Installation ....................................................................................................... - 3 -
3.3 Leveling ........................................................................................................... - 3 -
3.4 Power Connection ......................................................................................... - 3 -
3.5 Rechargeable battery operation .................................................................. - 3 -
3.5.1 Charging the battery .......................................................................... - 4 -
3.5.2 Battery maintenance .......................................................................... - 4 -
4. KEYBOARD AND DISPLAY .................................................................................. - 5 -
5. OPERATION............................................................................................................. - 7 -
5.1 Power On/Off .................................................................................................. - 7 -
5.2 Zero .................................................................................................................. - 7 -
5.3 Tare .................................................................................................................. - 7 -
5.4 Select Weighing Units ................................................................................... - 8 -
5.5 Percent Weighing ......................................................................................... - 8 -
5.6 Parts Counting ............................................................................................... - 8 -
5.7 Tolerance checking ....................................................................................... - 9 -
5.7.1 Limits setting for target weight ......................................................... - 9 -
5.7.2 Limits setting for target quantity ..................................................... - 10 -
5.7.3 Limits setting for target percentage ............................................... - 10 -
5.8 Accumulation ................................................................................................ - 12 -
5.8.3 Memory Clear ................................................................................... - 12 -
5.8.4 Automatic Accumulation .................................................................. - 13 -
5.9 Printing .......................................................................................................... - 13 -
5.10 Back Light Setting ..................................................................................... - 13 -
5.11 Power Auto Off .......................................................................................... - 14 -
5.12 Check Internal Counts .............................................................................. - 14 -
5.13 Gravity Setting .......................................................................................... - 14 -
5.14 Capacity Settings ...................................................................................... - 15 -
6. PARAMETER ......................................................................................................... - 16 -
7. CALIBRATION ....................................................................................................... - 19 -
8. RS232 OUTPUT .................................................................................................... - 20 -
9. ERROR CODES .................................................................................................... - 23 -
10. SPECIFICATIONS............................................................................................... - 23 -
10.2 DIMMENSIONS(inch/mm) ............................................................................... - 25 -

TVD Series Multifunction Scale Scale Technical Manual

TVD Series Multifunction Scale Scale Technical Manual
-
1
-
1. PRECAUTIONS
WARNING
DISCONNECT ALL POWER TO THIS UNIT
BEFORE INSTALLING, CLEANING, OR
SERVICING. FAILURE TO DO SO COULD
RESULT IN BODILY HARM OR DAMAGE THE
UNIT.
CAUTION
Permit only qualified persons to service the instrument
Before connecting or disconnecting any components, remove the
power.
Failure to observe these precautions bodily harm or damage to or
destruction of the equipment.
Avoid installing the scale in direct sunlight, which may cause discoloration.
Avoid overloading that could cause damage to the scale.
If the scale is not to be used for a long period of time, remove battery from
the battery compartment to avoid leakage.
Avoid stack materials on the scales, when scale is not in use.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate.
Do not place near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity
such as welding equipment or large motors.
Only use original adaptor, other could cause damage to the scale.

TVD Series Multifunction Scale Scale Technical Manual
-
2
-
2. INTRODUCTION
2.1 General
The TVD series weighing scales are suitable for general weighing, check
weighing, simple parts counting, percent weighing ,accumulation and units
conversion.
Capacities from 3kg to 30kg (6lb to 60lb).
Rechargeable battery provide up to 70 hours of continues use (with out
backlight).
Large 24mm LCD with white LED back light display.
7 embossed membrane keys.
2.2 Over view
1. SST Pan
2. Weight Display
3. Key board
4. RS232 port
5. Power switch
6. AC adapter jack
7. Adjustable leveling Foot
1
2
3
4
5
6
7

TVD Series Multifunction Scale Scale Technical Manual
-
3
-
3. INSTALLATION
3.1 Unpacking
When you receive the scale, inspect it to make sure that it is not damaged and
that all are parts are included:
Remove the scale from the carton.
Remove the protective covering. Store the packaging and to use if you
need to transport the scale later.
Inspect the scale for damage.
Make sure all components are included.
1. Scale
2. Adaptor
3. Manual
4.Stainless steel pan
3.2 Installation
Remove transport lock from bottom of the scale base
Place the scale on a level surface
Place the ABS plastic pan(2)on top of the scale base(3)
Install the stainless steel pan(1)on top of the plastic pan(2)
3.3 Leveling
The scale is equipped with a level indicator located left side of keyboard
Use the adjustable leveling feet located on the
bottom of the scale until the bubble appears in
the center of the indicator.
3.4 Power Connection
Connect the adaptor pin in to the indicator adaptor jack.
Adaptor jack is locating below the right side of the scale.
Adaptor connects into your AC power socket. Plugable equipment must be
installed near an easily accessible socket outlet with a protective ground/
earth contact.
3.5 Rechargeable battery operation
Note: Please charge the battery before using the scale for the first time.
The symbol on the weight display indicates that the battery is getting
low. It means that it’s time to charge the battery with the AC power. If
scale goes on being used without proper charging, <BAT-LO> words will
be showed on the display.

TVD Series Multifunction Scale Scale Technical Manual
-
4
-
Approximately 1 hours of instrument usage are left; afterwards it will shut
off automatically.
Please use the supplied battery charger for charging the battery
immediately,or scale cannot be used.
3.5.1 Charging the battery
Before the first use, the battery should be charged by connecting it to the
mains power supply for at least 12 hours.
When the scale is plugged into the mains power the internal battery will be
recharged.
Verify that the AC power socket outlet is properly protected.
Right side of the display there is an LED to indicate the status of battery
charging. When the scale is plugged into the mains power the internal
battery will be recharged.
If the LED is green, the battery has a full charge.
If it is red, the battery is nearly discharged
3.5.2 Battery maintenance
Do not use any other type of power adaptor than the one supplied with the
scale.
Recharge battery should be changed in every three months when not in
use.
If the scale is not used for an extended period of time,remove the battery
from the battery compartment to avoid leakage.
Store the battery in a sealed bag or box in a dry, temperate environment.

TVD Series Multifunction Scale Scale Technical Manual
-
5
-
4. KEYBOARD AND DISPLAY
4.1 Keyboard
Keys Function Function in menu
Zero key
Returns the display to zero
Confirm key
To enter selected sub-menu
in settings
Tare key
Used to perform a tare function,
Subtracts weights
Value increment key
Used to change the selected
digit value
Scroll up key
To change sub-menu in
parameter settings
Limit key
Set the limits for tolerance
checking
Right arrow key
Used to move the digit to the
right
Scroll up menu in parameter
settings
Percent key
Enters the percent weighing
function
To show weight, unit weight
and counts when counting parts
Left arrow key
Used to move the digit to the
left
Scroll down menu in
parameter settings
Sampling key
To switch from parts weighing
to parts counting
Clear key
Used to reset parameters or
clear the total accumulated
values
Escape key
To return to normal weighing
mode in other operating
mode or in parameter
settings

TVD Series Multifunction Scale Scale Technical Manual
-
6
-
Print key
Used to send data to PC or
printer
Accumulation key
To add the value to the
accumulation memory, if the
accumulation function is not
automatic
Memory recall key
To show the stored values from
the memory
N.A
Units key
Used to select weighing units
(kg/
g
)
N.A
4.2 Display Symbols
Battery indicator. When it’s
illuminated, battery should be
recharge
Indicate when the load above (HI),
load below (LO) and with in the
limits (OK) in check weighing
mode.
Gross
Gross Weight
Net
Net Weight
Ο Stable indicator. When it’s
illuminated, the scale is stable
Zero Zero indicator. When it’s
illuminated, the scale is in Zero
point
k
g
Kilogram Mode
lb
Pound
Mode
LED
Battery char
ging indicator

TVD Series Multifunction Scale Scale Technical Manual
-
7
-
5. OPERATION
Initial Start-up
Warm-up time of 15 minutes stabilizes the measured values after switching on.
5.1 Power On/Off
Power switch is located below the right side of the scale.
1 Turn the scale ON; press the switch forward and hold. The scale will show
the capacity and enter a self-test mode and follow to enter the weighing
mode.
2 Turn the scale OFF, press the switch forward once again.
5.2 Zero
Environmental conditions can lead to the balance exactly zero in spite of the
platform not taking any strain. However, you can set the display of your balance
to zero any time by pressing key and therefore ensure that the weighing
starts at zero.
5.3 Tare
The weight of any container can be tared by pressing button so that with
subsequent weighing the net weight of the object being weighed is always
displayed.
1 Load weight on the platform.
2 Press key. Zero is displayed, and tare is subtracted.
3 Remove weight on the platform. Tared weight is displayed. It can set only one
tare value. It will be shown with a minus value.
4 To clear the tare value, remove the load and press key. Zero is
displayed, tare weight is cleared.
Otros manuales para TVD Series
1
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Escala de Vision Tech Shop

Vision Tech Shop
Vision Tech Shop TVC Series Manual de usuario

Vision Tech Shop
Vision Tech Shop TVC Series Manual de usuario

Vision Tech Shop
Vision Tech Shop VK-2D Manual de usuario

Vision Tech Shop
Vision Tech Shop TPD Series Manual de usuario

Vision Tech Shop
Vision Tech Shop DLP-300 Manual

Vision Tech Shop
Vision Tech Shop VK-10S Manual de usuario

Vision Tech Shop
Vision Tech Shop TVP Series Manual de usuario

Vision Tech Shop
Vision Tech Shop DSW-100 Manual de usuario

Vision Tech Shop
Vision Tech Shop VK-4C Manual de usuario

Vision Tech Shop
Vision Tech Shop TVD Series Manual de usuario