Viessmann Solar-Divicon Guía rápida

Installation and
service instructions
Solar−Divicon, part no.7188391 and 7188392,
Solar circuit pump line, part no.7188393 and 7188394
Safety instructions
¨Please observe these safety instructions.
Installation, initial start−up, inspection,
maintenance and repairs must be
carried out by a competent person
(heating engineer/installation
contractor).
Before working on the equipment/
heating system, isolate the power
supply (e.g. by removing a separate
mains fuse or by means of a mains
isolator) and safeguard against
unauthorised reconnection.
When using gas as fuel, also close
the main shut−off valve and safeguard
against unauthorised reopening.
It is not permitted to carry out repairs
on parts that fulfil a safety function.
For replacements, use only original
spare parts from Viessmann or those
which are approved by Viessmann.
Dimensions
ASolarDivicon
BSafety assembly
CSolar circuit pump line
5862810GB5/2005 Please keep safe
380
240
0
20
40 60 80
100
120 0
20
40 60 80
100
120
380
210
0
20
40 60 80
100
120
A
B
C

2
Assembly and installation information
HThe Solar−Divicon comprises:
pre−assembled and sealed valves
and safety assembly
Flow regulating valve to control
the solar heating system during
the initial start−up and operation
Non−return valve in the flow and
return pipe
HAlways install Solar−Divicon so that
steam cannot enter the expansion
vessel in the event of stagnation.
HThe Solar−Divicon and the solar
circuit pump line are not suitable
for direct contact with swimming
pool water.
HFlush the system with process
medium after draining.
HIf the expansion vessel is installed
as high or higher than the
Solar−Divicon, a thermal insulation
loop is required.
HA pre−cooling vessel connection is
fitted to the flow line to protect the
expansion vessel against excess
temperatures.
HUse only gunmetal, brass fittings,
copper pipes or Viessmann
stainless steel solar circuit pipes
for the installation. Never use
galvanized/zinc−plated pipes,
fittings or graphitised gaskets. Use
hemp only in conjunction with
pressure and temperature−resistant
sealants (e.g. ViscotexSolarpaste,
Locher & Co. AG, CH9450Altstätten).
Components that come in contact
with process medium must be
resistant to the medium.
HCheck the sealing surfaces for
cleanliness and damage before
assembly.
Installation of the locking ring fittings
HAll pipes must be cut at a right
angle and deburred.
HInsert the support sleeves into the
pipework.
HPush the union nut and the locking
ring onto the pipe and lightly
lubricate the threads with oil.
HPush the pipe into the locking ring
fitting as far as it will go.
HInitially turn the union nut by hand,
then tighten with an open ended
spanner by a further ¾ turn.
HNever fit annealed copper pipes
onto the locking ring fittings.
5862810GB

3
Assembly and installation information (cont.)
System with SolarDivicon
ASolarDivicon
BSolar circuit pump line
CCollector
DExpansion vessel
EManual solar fill pump
FFill valve
GShut−off valve
HDrain valve
KFilling assembly
LConnections to the DHW cylinder
MAir separator
NSolar control unit
OAir vent valve
PPre−cooling vessel (if required)
System with SolarDivicon and solar
circuit pump line
Position the solar circuit pump line
to the right near the Solar−Divicon.
The Solar−Divicon pump acts as a
bypass pump, the solar circuit pump
line pump as a solar circuit pump. In
this case fit the safety assembly onto
the solar circuit pump line.
RL Return
VL Flow
5862810GB
A
C
O
N
L
M
G
K
F
E
D
TT
T
VL RL
H
P
D
B
C
O
L
M
G
K
F
E
D
TT
VL RL
T
T
A
H
T
N
P
D

4
Fitting the Solar−Divicon
5862810GB
or
8mm
or
5.
3.
4.
1.
2.
3.

5
Fitting the Solar−Divicon (cont.)
1. Pull the upper section of the
thermal insulation forwards.
2. Secure the valve assembly
together with the lower part of the
thermal insulation.
3. Installation with copper pipes
Insert the support sleeves into the
interconnecting pipes of the solar
circuit.
Alternative:
Installation with stainless steel
solar circuit pipe
Trim (free of burrs) in the valley of
the corrugation; do not damage
the peak of the corrugation. Fit the
union nut, half washer (in the fifth
valley) and O−rings (in the first and
third valley).
4. Insert a support sleeve into the
connection pipe to the expansion
vessel and secure on the safety
assembly.
5. Secure the blow−off line with the
safety valve from the safety
assembly; ensure the correct
orientation of the locking ring.
Note
The blow−off line must terminate
in an open container.
6. Route the connecting cable for the
circulation pump downwards
through the cable duct and
connect to the solar control unit.
Installation and service
instructions solar
control unit
7. Push the thermal insulation over
the valve assembly.
8. Push the thermal insulation of the
pipework into the recesses of the
thermal insulation of the
Solar−Divicon.
5862810GB
6.
7.

6
Fitting the solar circuit pump line
5862810GB
8mm
or
1.
4.
5. 1.
1.
2.
3.
or
4.
5.

7
Fitting the solar circuit pump line (cont.)
1. Pull the upper section of the
thermal insulation forward and
remove the valve assembly.
2. Secure the retaining plate.
3. Insert the valve assembly.
4. Installation with copper pipes
Insert the support sleeves into the
interconnecting pipes of the solar
circuit.
Alternative:
Installation with stainless steel
solar circuit pipe
Trim (free of burrs) in the valley of
the corrugation; do not damage
the peak of the corrugation.
Fit the union nut, half washer (in
the fifth valley) and O−rings (in the
first and third valley).
5. Slide the thermal insulation under
the assembly.
Follow the instructions below or
those on page8.
Fitting the solar circuit pump line separately or on
the left next to the Solar−Divicon.
5862810GB
6.
8.
7.

8
Fitting the solar circuit pump line (cont.)
6. Close the opening of the solar
circuit pump line with the cap and
the flat packing supplied.
7. Route the connecting cable for the
circulation pump downwards
through the cable duct and
connect to the solar control unit.
Installation and service
instructions solar
control unit
8. Push the thermal insulation over
the valve assembly and click it into
place.
9. Push the thermal insulation of the
pipework into the recesses of the
thermal insulation of the pump
line.
Fitting the solar circuit pump line to the right next to the
Solar−Divicon
5862810GB
9.
8.
7.
6.
10.

9
Fitting the solar circuit pump line (cont.)
6. Dismantle the safety assembly of
the Solar−Divicon and secure it on
the solar circuit pump line.
7. Close the opening of the return
line of the Solar−Divicon with the
cap and the insert.
8. Insert a support sleeve into the
connection pipe to the expansion
vessel and secure on the safety
assembly.
9 Secure the blow−off line on the
safety valve of the safety
assembly; ensure the correct
orientation of the locking ring.
Note
The blow−off line must terminate
in an open container.
10. Route the connecting cable for
the circulation pump downwards
through the cable duct and
connect to the solar control unit.
Installation and service
instructions solar
control unit
11. Remove the knock−out for the
safety assembly.
12. Push the thermal insulation over
the valve assembly and click it
into place.
13. Push the thermal insulation of
the pipework into the recesses of
the thermal insulation of the
pump line.
5862810GB
12.

10
Commissioning
Flushing and draining the solar heating system
Turn the integral non−return valves in the flow and return lines to "ON" by
turning the thermometer 45ºclockwise.
Pump curves
Match the flow rate via the output stages of the circulation pump to the
number of collectors or collector surface area.
"Vitosol" service instructions
APressure drop curve of the Solar−Divicon
5862810GB
Pump rate in l/h
0 500 1000 1500 2000 2500
0 0.5 1.0 1.5 2.0 2.5
Type PS 10 or P 10 A
Head in m
0
7
1
2
3
4
5
6
Pump rate in m3/h
Este manual sirve para los siguientes modelos
8
Tabla de contenidos
Manuales populares de Sistema de agua de otras marcas

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manual de usuario

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manual de usuario

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manual de usuario

Microline
Microline T.F.C.-4 Manual

Eureka Forbes
Eureka Forbes Aquaguard Select Manual de usuario

Cetetherm
Cetetherm AquaEfficiency Manual de usuario