Viavi Seeker HL Manual de usuario

Seeker HL
Source Transmitter
User’s Guide

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018Page 2
Notice
Every effort was made to ensure that the information in this manual was accurate at the time
of printing. However, information is subject to change without notice, and VIAVI reserves the
right to provide an addendum to this manual with information not available at the time that this
manual was created.
Copyright/Trademarks
© Copyright 2018 VIAVI Solutions Inc. All rights reserved. No part of this guide may be
reproduced or transmitted, electronically or otherwise, without written permission of the
publisher. VIAVI Solutions and the VIAVI logo are trademarks of VIAVI Solutions Inc. (“Viavi”).
All other trademarks and registered trademarks are the property of their respective owners.
Copyright release
Reproduction and distribution of this guide is authorized for US Government purposes only.
Ordering information
This guide is a product of VIAVI Technical Publications Department, issued as part of the
product. The catalog number for a published guide is Catalog Number - printed. The catalog
number for an electronic guide on USB is Catalog Number - electronic.
Terms and conditions
Specications, terms, and conditions are subject to change without notice. The provision
of hardware, services, and/or software are subject to VIAVI standard terms and conditions,
available at www.viavisolutions.com/en/terms-and-conditions.

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018 Page 3
Table of Contents
Chapter 1
General Information ..................................................................................................................5
Ordering Information ..............................................................................................................5
Where to Get Technical Support ............................................................................................5
How this Manual is Organized ...............................................................................................5
Conventions Used in this Manual...........................................................................................6
Precautions ............................................................................................................................6
Periodic Calibration................................................................................................................6
Chapter 2
Introduction & Operation..........................................................................................................7
What is the Seeker HL Source Transmitter?..........................................................................7
Overview...........................................................................................................................7
Testing Approach ..............................................................................................................7
Equipment Supplied with the Seeker HL Source Transmitter ................................................8
Replacement Parts.................................................................................................................9
Field Accessories ...................................................................................................................9
A Guided Tour of Your Seeker HL Source Transmitter.........................................................10
Front View.......................................................................................................................10
Rear View .......................................................................................................................11
Left Side View.................................................................................................................12
Battery Charging ..................................................................................................................13
Battery Charge Indicator LED.........................................................................................13
Operation .............................................................................................................................14
Power Indicator LED.......................................................................................................14
Transmit Level Adjustment .............................................................................................14
Chapter 3
Appendix ..................................................................................................................................15
Specications.......................................................................................................................15
Limited Warranty ..................................................................................................................16

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018Page 4

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018 Page 5
How this Manual is Organized
This manual is divided into the following chapters:
• Chapter 1, “General Information” provides contact information and describes how this
operation manual is structured.
• Chapter 2, “Introduction & Operation” introduces what the Seeker HL Source
Transmitter is and what it does. This chapter discusses the practical application,
connections and controls of the Seeker HL Source Transmitter.
• Chapter 3, “Appendix” shows the technical specications and warranty information of
the Seeker HL Source Transmitter.
General Information
Chapter 1
Ordering Information
Where to Get Technical Support
Phone US: +1-844-GO-VIAVI or +1-844-468-4284
Outside US: +1-855-275-5378
Email: T[email protected]
Website: https://support.viavisolutions.com/welcome
For additional information about our products and services, contact your local VIAVI
representative or visit https://www.viavisolutions.com/en-us/how-buy.

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018Page 6
Conventions Used in this Manual
This manual has several standardized conventions for presenting information:
• Connections, menus, menu options, and user-entered text and commands appear in
bold.
• Section names, web, and e-mail addresses appear in italics.
Precautions
Periodic Calibration
The chosen frequency must closely match that of the leakage detector or leaks will not be
detected properly. If the Seeker HL Source Transmitter appears to be out of calibration, the unit
must be returned to VIAVI or an authorized repair center for re-calibration.
A CAUTION alerts you to any condition that could cause a
mechanical failure or potential loss of data.
A NOTE is information that will be of assistance to you related
to the current step or procedure.
A WARNING alerts you to any condition that could cause
personal injury.
Do not use the Seeker HL Source Transmitter in any manner
not recommended by the manufacturer.
A strong electromagnetic eld may affect the measurement
accuracy of the Seeker HL Source Transmitter.

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018 Page 7
Introduction & Operation
Chapter 2
What is the Seeker HL Source Transmitter?
Overview
Mitigation of signal leakage within the subscriber premise is essential for the successful
operation of the subscriber’s cable and cellular services. To thoroughly evaluate the potential
for interference to subscriber services, VIAVI has developed a patent pending approach to
signal leakage measurement which will comprehensively test the Aeronautical and LTE bands
in both fully digital and analog cable systems.
Historically, signal leakage detectors have required high levels of sensitivity to measure signal
leakage radiating from the CATV system. Measurement within the subscriber premise and the
migration to all digital services places even greater sensitivity requirements upon the leakage
detector combined with a new requirement to simultaneously monitor for signal leakage in both
the aeronautical and LTE bands.
In laboratory experiments signal leakage measurements as low as 0.1 uV/m have proven
sufcient to allow LTE signals to enter the subscriber network and disrupt cable services.
Achieving a measurement sensitivity of 0.1 uV/m is beyond the measurement range of
conventional signal leakage detectors and requires a new approach to leakage detection within
the subscriber premise.
Testing Approach
To meet the new measurement and sensitivity requirements, the Seeker HL monitors 138
MHz and 757.5 MHz simultaneously, supporting testing in both the Aeronautical and LTE
frequency bands. The Seeker HL Source Transmitter replaces the cable service with two
high-output test carriers which pressurize the subscriber cabling, revealing any damage
which may lead to service interruption from ingressing LTE carriers.
The Seeker HL Source Transmitter has two output levels: a +60 dBmV for home
certication and a +40 dBmV output level should the subscriber network prove too porous
for pinpointing the location of a leak at the higher transmit level.
The displayed leakage levels are normalized by the Seeker HL receiver to reect the value
of the leak at nominal systems levels within the subscriber premise. The normalization
of the measured and displayed leakage levels simplies the evaluation of leakage
severity and provides consistency for documentation of leakage levels in accordance with
established industry practices.

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018Page 8
When utilizing the higher +60 dBmV transmit level the Seeker HL is able to locate signal
leakage down to a normalized leakage level of 0.1 uV/m with a single exible antenna;
making it possible to locate and repair signal leakage levels far beyond the measurement
range of conventional leakage detectors.
Equipment Supplied with the Seeker HL Source
Transmitter
The Seeker HL Source Transmitter comes with the following:
• Seeker HL Source Transmitter
• One Built-In Li-Ion Battery
• AC to DC Power Adapter & Battery Charger

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018 Page 9
Replacement Parts
The following replacement parts are available for the Seeker HL Source Transmitter:
Part Number Description
0090061000 Li-ION Replacement Battery (Replacement Requires 1 Battery)
0610198000 AC to DC Power Adapter & Battery Charger
0190197000 AC US Power Cable
Field Accessories
The following accessories are available for the Seeker HL Source Transmitter:
Part Number Description
2071527048 Precision RF Coaxial Test Cable (I/O-15)
2072097000A Vehicle Power Adapter
0190322000 AC Euro Power Cable
To place an order, contact your local VIAVI representative, call 1-844-GO-VIAVI, or visit
https://www.viavisolutions.com/en-us/how-buy.

Seeker HL Source Transmitter
User’s Guide
Document Num., Rev. 2
May 2018Page 10
A Guided Tour of Your Seeker HL Source Transmitter
Before using your instrument take a few minutes to familiarize yourself with the instrument,
its basic conventions and its navigational tools. This section provides a brief overview of the
instrument’s features, buttons, and controls.
Front View
RF Output Connector
Power Button
Transmit Level Button
Power Indicator LED
Transmit Level Indicator LED
Battery Charge Indicator LED
DC Charge Port
with Protective
Rubber Door
Otros manuales para Seeker HL
1
Tabla de contenidos
Otros manuales de Transmisor de Viavi
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario












