Veichi SI30 series Manual de usuario

NEW SI30 Solar Pump Inverter

SI30 Solar Pump Inverter Manual
1
Chapter 1 Safety Requirement and Cautions
To ensure safety of your health, equipment and property, please read this chapter carefully before
using the solar pump inverter and act in compliance with the instructions when installing, debugging,
running and overhauling the inverter.
1.1 Safety Definition
Danger: it will cause danger of serious injuries and even death while operating against the rules.
Caution: it will cause danger of light injuries or equipment destruction while operating against the
rules.
Note: some information is useful while operating and using solar pump inverter.
1.2 Safety Requirements and Cautions
● Before Installation
Danger
1. Only qualified personnel can operate the equipment. Before operating, be sure to carefully
read the manual. The safe operation depends on the proper processes of choosing models,
carrying, installation, operation and maintenance.
2. Don’t use the damaged or incomplete solar pump inverters; Otherwise, there is risk of injury.
● Installation
Danger
1. Please install the solar pump inverter on metal or other nonflammable material, and keep it
away from the combustible material. Otherwise there is danger of fire.
2. No unauthorized modification to the solar pump inverter; Otherwise there is danger of
damage.
3. Normal solar pump inverter without explosion-proof cannot be installed where with explosive
gas or dust; Otherwise there is danger of explosion.
● Wiring
Danger
1. Wire is connected only when the main circuit is cut off, otherwise there is a danger of shock.
2. Wire is connected by professional person only. Otherwise there is a danger of shock.
3. Earth must be reliable. Otherwise there is a danger of shock.
4. DC power supply should not be connected to output terminals U, V, W, otherwise there is a
danger of damage to solar pump inverter.
5. No drop of bolt, spacer, metal stick, conducting wire or other things into the inner of solar
pump inverter; Otherwise there is a danger of fire or damage to solar pump inverter.

SI30 Solar Pump Inverter Manual
2
Attention
1. If the damage to solar pump inverter or other equipment is caused by improper wiring and
utilization or unauthorized alteration, the user should shoulder all responsibilities.
2. Please make sure all wirings meet EMC requirements and satisfy safety standards in the
local area; Please refer to recommendations in this manual or national standards of wire
diameter to avoid accidents.
3. Static electricity on human body would seriously damage internal MOS transistor, etc. Don’t
touch the printed circuit boards, IGBT or other internal devices without anti-static
measurements;otherwise it will cause the malfunction to solar pump inverter.
4. Please don't connect phase shift capacitance or LC/RC noise filter to the output circuit of
solar pump inverter; Otherwise it will damage the inverter.
5. Please don't connect the magnetic switch or magnetic contactor to the output circuit of solar
pump inverter; When solar pump inverter is in the operation with load, magnetic switch or
magnetic contactor can make inverter over-current protection act. It will damage solar pump
inverter seriously.
6. Please don't dismantle the panel cover, and it only needs to dismantle the terminal cover
when wiring.
7. It is forbidden to do any pressure test on solar pump inverter, otherwise it will damage the
solar pump inverter.
● Before Electrification
Danger
1. Please make sure that voltage grade of power supply is consistent with solar pump inverter's
rated voltage and then check whether the wiring is correct, and whether there is short circuit
in peripheral equipment's circuit. Otherwise it will damage solar pump inverter and other
equipment.
2. Before the solar pump inverter is connected to the input power supply, make sure that the
cover has been well fixed. Otherwise it will cause electric shock.
3. For the solar pump inverters whose storage time is over 1 year, when electrification, the
voltage should be raised by booster from low to high. Otherwise it will damage the solar
pump inverter.
Attention
1. Check if all periphery fittings are wired properly according to the handbook; Otherwise it will
cause accidents.

SI30 Solar Pump Inverter Manual
3
● After Electrification
Danger
1. After electrified, it is forbidden to open the cover, make wiring, and check up; Otherwise, it will
cause the danger of electric shock.
2. After electrified, it is forbidden to contact internal wiring board and its parts. Otherwise it will
cause the danger of electric shock.
3. Do not operate or touch solar pump inverter with wet hand. Otherwise there is danger of
damage to solar pump inverter and electric shock.
Attention
1. Please set the parameter of solar pump inverter cautiously; Otherwise it will damage
equipment.
● Operation
Danger
1. Before running, please check and confirm the application range of the machine and
equipment once more; Otherwise it will cause accidents.
2. Please don't touch the cooling fan and braking resistance to check the temperature;
Otherwise there is a danger of getting burn.
3. Unprofessional workers are banned to check the signals in the running stage; Otherwise it
will cause injuries and damage the equipment.
Attention
1. Please don't turn off the equipment by switching off power; Please cut off the power supply
after the electric machine stops running; Otherwise it will damage the solar pump inverter.
2. Please avoid anything dropping into the equipment when the solar pump inverter is running;
Otherwise it will cause electric shock.
● Maintenance
Danger
1. Please don't maintain and repair the equipment with electric; Otherwise it will cause electric
shock.
2. Before maintaining and repairing the solar pump inverter, please make sure the indicator
lights of power supply have completely turned off; Otherwise it may cause electric shock and
damage the solar pump inverter.
3. Persons who have not passed specialized train are not allowed to conduct the solar pump
inverter maintenance; Otherwise it may cause electric shock and damage the solar pump
inverter.

SI30 Solar Pump Inverter Manual
4
1.3 Cautions in Using
1. In application of this series solar pump inverter, you have to confirm all machine insulation to
prevent damage to the equipment. Moreover, when the motor working in tough environment, please
periodic inspect the electrical insulation to ensure the safety of the system work.
2. If the motor adapter is not consistent with solar pump inverter's rating current (The rating current
of the motor is far smaller than that of solar pump inverter), please adjust the protective value to ensure
safe running.
3. In occasions such as load raises, usually there is negative torque and solar pump inverter breaks
off for over-current or over-voltage. In this case, you should consider choosing the matching brake unit.
4. Solar pump inverter, in a certain output frequency range, can meet the mechanical resonance of
the load equipment. To avoid it, you can set up jumping frequency.
5. As output voltage of the inverter is pulse-wave type, if there is capacity which can improve power
factor or pressure-sensitive resistance which used for thunder-proof in the voltage output side, the solar
pump inverter will break off or its parts will be damaged, so it is necessary to dismantle them. Moreover, it
is proposed not install switch parts like air switch and contactor (if it is necessary to install switch on
output side, please make sure the output electricity of solar pump inverter is zero when the switch is
working).
6. At over 1,000 meters altitude, the inverter’s heat dissipation function worsened due to the thin air,
it is necessary to use less.
7. The inverter output voltage is pulse wave type. If using digital multi-meter measurement, deviation
of the reading will be great. And the deviation is different by using different type of digital multi-meter.
Under normal circumstances, while RMS 380V, digital multi-meter reading is around 450V.
8. Solar panel can be connected in series or parallel. For rated voltage 380V controller, we suggest
solar panel open circuit voltage should be between 620V~750V.
1.4 Technical Specification
Solar pump
inverter
power(kW)
Pump Max solar power
input
(kW)
Max DC
input
voltage (V)
Recommend
Voc voltage (V)
Rated
output
current
(A)
Output
frequency
(Hz)
Rated
power
(kW)
Rated
voltage
(V)
SI30-D1 series, DC90V-400V input,3 phase AC110V-230V output, MPPT voltage range DC90V-400V,for AC110V pumps
0.75 0.75 110 1.0 400 175~380 7A 0-320
1.5 1.5 110 1.95 400 175~380 10A 0-320
SI30-D3 series,DC150V-450V input,3 phase AC220V-240V output, MPPT voltage range DC150V-450V, for AC220V pumps
0.75 0.75 220 1.0 450 360~430 4A 0-320
1.5 1.5 220 1.95 450 360~430 7A 0-320
2.2 2.2 220 2.86 450 360~430 10A 0-320
SI30-D5 series,DC300V-850V input,3 phase AC230V-460V output, MPPT voltage range DC300V-800V,for AC380V pumps
0.75 0.75 380 1.0 850 620~750 2.5 0-320
1.5 1.5 380 2.2 850 620~750 3.7 0-320
2.2 2.2 380 3.3 850 620~750 5.0 0-320
4 3.7 380 5 850 620~750 10 0-320
5.5 5.5 380 8 850 620~750 13 0-320

SI30 Solar Pump Inverter Manual
5
7.5 7.5 380 10 850 620~750 17 0-320
11 11 380 14.3 850 620~750 25 0-320
1.5 Cautions in Disposal
When you dispose solar pump inverter, please pay attention to:
1. Electrolytic capacitor: the electrolytic capacitor of main circuit or the printing plate may explode when
they are burned.
2. Plastic: plastic incineration may generate toxic gases.
3. Dispose method: please dispose as industrial waste.

SI30 Solar Pump Inverter Manual
6
Chapter 2 Installation and Wiring
2.1 Products Appearance
2.2 Open Cover
Remove 4 fixed screws in the cover and turn from right to left to open the top cover, as shown below:

SI30 Solar Pump Inverter Manual
7
2.3 Wiring and grounded(The ground wire must be firmly connected)
2.4 Inverter Dimension
285
308
350
369
446.5
260
260
7.5(installation hole)
285
203

SI30 Solar Pump Inverter Manual
8
2.5
Terminal diagram
●
Control loop terminal instructions
Terminal
Function definition Description
+10V 10V auxiliary power supply output, constitutes loop with MAX output 50mA
+24V 24V auxiliary power supply output, constitutes loop with MAX output 100mA
COM 24V power reference ground MAX output 24VDC/100mA
A+ RS485 communications
+
B- RS485 communications
-
AI1 analog input 1 Voltage, current type optional
AI2 analog input 2 Voltage, current type optional
GND analog signal ground
X1 Forward running input, and constitutes loop with COM
X2 Reverse running input, and constitutes loop with COM
X3 Full water detection alarm, and constitutes loop with COM
X4 Full water detection reset, and constitutes loop with COM
RJ45 External keyboard connection terminal
2.6 Terminal diagram

SI30 Solar Pump Inverter Manual
9
Chapter 3 Basic Operation and Trial Run
3.1 Keyboard Layout and Function Specification (optional)
●
Keyboard Appearance
●
Key Function
Symbol
Double-line
keyboard Function
A Unit indicator Hz: Frequency A: Current V: Voltage V/A: Voltage or
current RPM: Speed %: Percentage
B Status Indicator On: Forward running status Blinking: Reverse running status
Off: Stop status
C
Menu Enter the function menu interface during standby or running;
press this button to exit the modification when the parameter is
modified; press the button (1 second) during standby or running
to enter the status interface directly.
F
Stop/Reset When the command given channel is keyboard control, press
this key to stop the inverter; the parameter [F04.08] can be used
to define whether other command channels are valid; the
inverter resets when pressing the key in fault status.
G
Digital potentiometer: clockwise to increase the operating value,
counterclockwise to decrease the operating value
Set key: After modifying the value, press this key to confirm the
modified value.
Left/Right Shift
Move left and right operation bits
H
Jog/Reverse Select the function of the key by parameter [F04.07], 0: reverse
1: jog
Otros manuales para SI30 series
1
Tabla de contenidos
Otros manuales de Inversor de Veichi

Veichi
Veichi AC200-L Series Manual de usuario

Veichi
Veichi AC100-T3-1R5G Manual de usuario

Veichi
Veichi SI22 series Manual de usuario

Veichi
Veichi SI23-D1 series Manual de usuario

Veichi
Veichi AC10 Series Manual de usuario

Veichi
Veichi SD700-1R1A series Manual de usuario

Veichi
Veichi AC70 series Manual de usuario

Veichi
Veichi SI30 series Manual de usuario

Veichi
Veichi SI23 series Manual de usuario

Veichi
Veichi AC200 Series Manual de usuario