VECTECH SD-150 Manual de usuario

VECTECH SD-150
Lead Free Soldering Station
High-power digital display lead-free soldering iron
High frequency heating 150W Rapid recovery
Operation Manual

Thank you for purchasing our lead-free soldering station, this product is specially designed for lead-free soldering, please
Read this manual carefully and keep it properly after reading it for future reference.
table of Contents
Precautions………………………………………………………………………
Part Name………………………………………………………………………
Installation and use of electric soldering iron…………………………………………………………
parameter……………………………………………………………………………
Sleep……………………………………………………………………
Choosing the right soldering iron tip for welding requirements…………………………………………
Calibrate soldering iron temperature………………………………………………………………
The use of soldering iron tip………………………………………………………………
Maintenance of the soldering iron tip………………………………………………………………
Error mark……………………………………………………………………
Troubleshooting guide………………………………………………………………
How to check heater and temperature sensor components………………………………………………
Replace the fuse………………………………………………………………

specification……………………………………………………………………………
Soldering iron tip………………………………………………………………
Precautions
△! caveat
The definitions of "Warning" and "Caution" in this manual are as follows:
! Warning: abuse may cause death or serious injury to users
△
△
! Note: Misuse may cause injury to the user or cause physical damage to the involved objects.
△ ! note

When the power is turned on, the temperature of the soldering iron tip is at a high temperature.
As abuse may cause burns or fire, please strictly observe the following:
●Please avoid abuse of this soldering station and use this product in accordance with the operating instructions.
●Do not touch the metal parts near the soldering iron tip.
●Do not use the soldering iron tip near flammable objects.
●Notify others in the workplace that the soldering iron tip is easily burned and may cause dangerous accidents. At rest or
after Turn off the power after work.
●When replacing the soldering iron tip of a component or device, turn off the power and wait for the soldering iron tip to
cool to room temperature.

In order to avoid damage to the soldering iron and to maintain a safe working environment, the following items should be
observed:
This product uses rated voltage and frequency. (Please refer to the logo on the back of the machine)
It is strictly prohibited to use this product when it is damaged, especially when the power cord is damaged.
This product uses a three-wire grounding plug, which must be inserted into a three-hole grounding socket. Do not
change the plug or Use an ungrounded three-head adapter to cause poor grounding. If you need to extend the wire,
please use a grounded three
Power cord.
Do not use the soldering iron tip for work other than soldering.
Do not knock the soldering iron on the workbench to remove the flux residue, which may severely shake the soldering
iron.
Do not modify the welding station without authorization.
When replacing parts, use the original factory originals.
Do not get the soldering station wet. Do not use or disassemble the soldering station when your hands are wet, nor pull
the power cord. Smoke will be emitted during welding, and the workplace should have good ventilation facilities.
When using the soldering station, do not make any rash actions that may harm your body or damage objects.
Children do not know the danger of electrical products, so this product should be inaccessible to children or have adult
supervision Use and store in the appropriate place.
●
●
●
●
●
●
●
●
●
●
●
Part Name
Assemble the wires
Soldering iron socket
Cleaning sponge
Soldering iron stand base

Device and use of electric soldering iron
A. Soldering iron stand
△
! Note: Sponge is a squeezable object, and it will expand when wet. When using a sponge, wet the water first and then squeeze it dry.
Otherwise, the tip of the soldering iron will be damaged.
1. Small cleaning sponge
Wet a small piece of cleaning sponge with water before squeezing
Dry, put it into the groove of the base of the soldering iron stand.
2 . Add water to the soldering iron rack. Cannot exceed the middle
Protruding part. After the small quick sponge absorbs water,
Can keep the large sponge on it
Stay wet.
* You can also use a large piece of sponge alone, (omit the small
Sponge and water)
3. Then moisten a large cleaning sponge and place
Soldering iron stand base.

B. connection
△
! Note: When connecting or disconnecting the soldering iron, remember to turn off the power to avoid damage to the soldering iron.
1 . Connect the assembly wire to the soldering iron pen socket
2 . Place the soldering iron on the soldering iron stand
3 . Insert the plug into the power outlet.
Remember to ground.
4 . Press the power switch.
The temperature is preset at the factory to be Celsius 300 degree
( 350 ℃) . Heat finger when the temperature is stable
The indicator light will flash.
Heating indicator
C. set temperature
General temperature setting
△
! Note: Make sure the soldering iron is in a temperature adjustable state (input the correct password or the password is the original password
code). When setting the temperature, the heating element is cut off. If you press the "*" key less than 1 Seconds, the
current set temperature will be displayed for two seconds, and then the temperature of the soldering iron tip will be displayed.

Example: Celsius 400 Degree changed to
350 degree. 1, Press the "*" key and hold at least 1 Second most
The left digit (hundreds digit) will flash. table
Indicates that the temperature of the soldering station is in the setting mode.
Bits can be adjusted.
1.
2, Select the desired value to replace the hundreds. use
"▲" or "▼" key to change the display
The values are shown in the figure below:
… 2 3
2 .
4 …
When the desired digit is displayed, press the * key.
The middle digit (ten digit) starts to flash, indicating
The ten digits can be set.
3. 3. Select the desired value to replace the tens place. use
"▲" or "▼" key to change the display
The values are shown in the figure below:
1 • 2 • 3 • 4 • 5 • 6 • 7 • 8 • 9 • 0
Press the * key.
The right digit (ones digit) starts to flash, indicating
The ones place can be set.
4 . 4. Select the desired value to replace the ones place. use
"▲" or "▼" key to change the display
Numerical value, select the tens position as shown above
law. Press the * key
Here, press the * key...
a. Enter the set temperature into the internal record
Memories
b. Display the set temperature
c. Start heater control

Note:
If you turn off the power switch while setting the temperature,
The set value will not be stored in the memory. If all
The set temperature value exceeds the settable range,
The display window will return to the hundredth place and flash, if
This happens, please re-enter the correct
The temperature value.
Instant temperature setting
If the heating body needs to be continuously powered during work
If you want to set the temperature quickly, you should select this method.
Heating up:
Without pressing the "*" key, press the "▲" key directly,
The set temperature rises by 1℃, and the display window shows
Display the set temperature, after releasing the "▲" key,
The display window delays the display of the set temperature for about 2 seconds,
If you press the "▲" key again within the delay of 2 seconds, then
The set temperature rises by 1℃; if you press "▲"
Hold for at least one second, then set the temperature quickly
Rise until the desired set temperature is released
"▲" key.

Cool down:
Without pressing the "*" key, press the "▼" key directly,
The set temperature drops by 1℃, and the display window shows
Display the set temperature, after releasing the "▼" key,
The display window delays the display of the set temperature for about 2 seconds,
If you press the "▼" key again within the delay of 2 seconds, then
The set temperature drops by 1℃; if you press "▼"
Hold for at least one second, then set the temperature quickly
Decrease until the desired set temperature is released
"▼" key.
parameter
The soldering iron uses the following parameters, which can be adjusted.
Set password
The original password of the main unit's memory is: "000", in this state, the temperature setting is allowed,
If the temperature adjustment is restricted, the password must be changed.
Enter password modification method
1. Turn off the power switch and press "▲" at the same time
And "▼", and then press the power switch.
2. Press and hold the "▲" and "▼" keys,
Until it shows .
3. When the window shows
The station enters the parameter setting mode.
,weld
Tabla de contenidos
Otros manuales de Pistola de soldar de VECTECH
Manuales populares de Pistola de soldar de otras marcas

Velleman
Velleman HRJA151 Manual de usuario

Weller
Weller WSM 1 Manual de usuario

Vishay Precision Group
Vishay Precision Group Micro-Measurements Mark V Instrucciones de montaje

ersa
ersa i-CON 1V Manual de usuario

Hakko Electronics
Hakko Electronics FX-100 Manual de usuario

Weller
Weller WAD 101 Manual de usuario