Uplift Desk Power & Data Rail Manual de usuario

For further info or assistance, visit upliftdesk.com
Patent Pending, ©2020 UPLIFT Desk®. All Rights Reserved
355 lb
two person
assembly
Power & Data Rail
Modular system for power and data solutions.
®

UPLIFT Power & Data Rail Components
Single row end foot
(PDC005-FOOT-SE)
Single row center foot
(PDC005-FOOT-SC)
Dual row end foot
(PDC005-FOOT-DE)
Dual row center foot
(PDC005-FOOT-DC)
Privacy panel brackets
(PDC005-PRV)
(Privacy Panels shipped separately)
Short wire trays
(PDC005-TRAY-SHT)
Long wire trays
(PDC005-TRAY-LNG)
Long rail assembly
(PDC005-RAIL-LNG)
Short rail assembly
(PDC005-RAIL-SHT)
Square post
(PDC005-POST-SQ)
120-Degree post
(PDC005-POST-120)
All components to make any conguration available on upliftdesk.com
Part numbers in parenthesis indicate how components are separated and shipped.

Serving as a central spine in a group of benched workstations or a border around other con-
gurations, the Power and Data Rail allows you to provide power and data to the following
common congurations and many more.
Dual Sided Row
H-Shape
3-Pack
Single Sided Row
Comprised of customizable features you won’t nd on any other power rail solution, our patent-pend-
ing Power and Data Rail is the most capable and exible solution for open ofce environments. Use
wherever access to power outlets is limited and eliminate cable clutter and the need for extension
cords.
The Power and Data Rail was designed to position UPLIFT V2 and V2-Commercial desks with con-
sistent alignment and spacing throughout your oor plan, but you can use it with virtually any desk.
The Power and Data Rail accepts both Byrne 8-Trac or Dekko 8-Wire UL recognized electrical com-
ponents. Both of these electrical systems offer quick-connect components for fast and simple in-
stallation. Connect up to 4 desks with the plug-in power infeed or 16 desks with the hardwire power
infeed.
Note: A licensed electrician is required for connection of the hardwire power infeed cables.
UPLIFT Power and Data Rail
4-Pack
C-Shape Herringbone
Dog Bone Shape

4
M6x6 Set screw
(installed in post)
Comes pre-assembled
Consists of:
Upper post
Inner sleeve
(inside)
Bottom post
Step 1
The posts are designed with recommended height
setting indicator lines on the Bottom post for UPLIFT
V2 and UPLIFT V2-Commercial desks. Using the in-
cluded 3mm Allen wrench, loosen the the two M6x6
Set screws so the Upper post can slide.
If you are using the Power and Data Rail with UPLIFT
V2-Commercial desks, slide the Upper post until the
bottom edge is aligned with the rst indicator line.
For UPLIFT V2 frames, slide the Upper post to the
second indicator line.
Once in place, tighten the Set screws again and con-
tinue this process with the rest of your posts.
Height setting for
V2-Commercial Frames
Height setting for
V2 Frames
UPLIFT V2 Desks
UPLIFT V2-Commercial Desks
3mm Allen
wrench
Square Post
Parts needed for this part of the assembly
Square Post Assembly

Step 1
The Square post feet are designed for Single Sided or
Dual Sided Row congurations as shown in the dia-
grams.
Regardless of the length of the row of desks, if you are
using UPLIFT V2 and UPLIFT V2-Commercial desks,
the end posts in the run will require End feet. The re-
mainder of the posts in the middle of the row will use
Center feet.
Important note: The large holes in each of the post
feet are designed to accept the leveling glides at the
back of the UPLIFT V2 and UPLIFT V2-Commerical
desk feet. This patent-pending feature helps to keep
your desks aligned and spaced properly.
For any non-UPLIFT V2 desks, we recommend us-
ing End feet with ALL posts as the larger Center feet
may interfere the feet of other desk styles.
Step 2
Use the M5x10 Flat head screws that were included
with each post to attach the feet as shown to the bot-
tom of each post assembly. The oval power infeed
hole should be facing to the left or right of the foot.
This way the holes will be below the rails.
Hand tighten each screw a few turns at rst. Once all
screws are started, tighten them with the included
3mm Allen wrench.
Step 3
Position posts approximately where they will be lo-
cated once the Power and Data Rail assembly is com-
plete.
We recommend locating one of the end posts in close
proximity to the power outlet (for plug-in power in-
feeds) or the junction box (for direct-wire power in-
feeds) with the Power infeed hole facing the power
source.
After the legs are generally where they need to be,
move on to the “Rail Assembly” section.
Parts needed for this part of the assembly
Single Sided Row
Dual Sided Row
Square Post Foot Selection & Assembly
M5x10 Flat head screw
(qty 4)
Dual row center foot
(qty 1)
Single row center foot
(qty 1)
Single row end foot
(qty 1)
Dual row end foot
(qty 1)
Power
infeed
hole
Power
source
3mm Allen wrench

6
Pictured here: Short Rail
(33.5” - 48.8” width adjustment between posts)
All rails come pre-assembled
Consisting of:
Cover
Rail housing
Rail extensions
(qty 2)
Also available: Long Rail
(51.5” - 73.8” width adjustment between posts)
Step 1
The Covers are not attached with screws during ship-
ment. Remove the Covers from each of the Rail as-
semblies and set them aside for later.
Remove the hardware and other components from
inside the Rail assemblies and set them aside for later
also.
Step 2
Turn each Rail assembly over and loosen the two
screws in each of the Rail extension washers using the
3mm Allen wrench. Do not remove the screws com-
pletely.
This will allow the Rail extensions to slide in and out of
the Rail housing.
Step 3
Move one of the Rail assemblies to the rst two Posts
in your conguration. Slide the Rail extensions in or
out as needed so that they can be hung on the Posts.
Note: Be sure that the upper and lower tabs on each
Rail extension are hooked over each Post top and
opening as shown.
Attach each Rail extension to each Post with an M5x12
Machine screw and tighten using the 3mm Allen
wrench.
M5x12 Screw
(qty 2)
Extension washer
(qty 2)
Parts needed for this part of the assembly
Assembly - Linear Congurations

Step 4
Move an UPLIFT V2 desk up to your rst Rail and Post
assembly. Slide the Posts in or out to align the holes in
the Post feet with the leveling glides in the back of the
desk feet as shown. Then, lift the desk slightly on each
side and set the desk glides into the Post feet holes.
If you are assembling a Dual Sided Row conguration,
we recommend placing the desks on the opposite
side of the Power and Data Rail after all the electrical
components have been installed and the assembly is
complete.
If you are not using UPLIFT V2 desks, slide the Posts
until the Rail assembly is about the same length as the
desktop and the Posts sit outside both sides of the
desk. You’ll want a 4 inch gap between sides of desk-
tops
Step 5
Continue adding Posts and Rail assemblies down the
row following Steps 3 and 4 above until all of the Rail
assemblies are attached to the posts.
Then continue to move your UPLIFT V2 desks into
place, locating the desk feet glides into the Post feet
holes.
Note: If you are assembling a Single Sided Row along
a wall, once all of the Posts are aligned with the desk
glides move the desks away from the Rail again. This
will make the rest of the assembly much easier.
Center post foot
End post foot
33.5’’ - 48.8’’
51.5’’ - 73.8’’
Short and Long Rail Lengths
Rail lengths needed are determined by the desk di-
mensions.
As a general rule, the length of the rail should be the
same length as the desktop it is being placed adjacent
to. This will create a gap of about 4 inches between
desktops. Rail measurements are taken from the fur-
thest ends of the Rail extensions where the Rail meets
the inside of the post. See diagrams to the left.
Short rails have a length adjustment range of 33.5’’ to
48.8’’
Long rails have a length adjustment range of 51.5’’ to
73.8’’

8
Use Single row end feet at “A” locations, facing inward.
Use Single row center feet at “B” locations, facing in-
ward.
Use Dual row end feet at “C” locations, perpendicular
to the rails.
Use Single row end feet at “A” locations, facing inward.
Use Single row center feet at “B” locations, facing in-
ward.
For non-linear congurations such as the C-Shape, H-Shape, 4-Pack, and Herringbone Shape, you will be
connecting Rail assemblies to other sides of the Square posts. Follow the same Rail extension attachment
process as shown in the section “Assembly - Linear Congurations” Step 3 (page 6).
The type of post feet used in non-linear congurations are dependent upon the type of desks used and
where the desk feet glides are.
Herringbone & C-Shapes H-Shape 4-Pack
Assembly - Non-Linear Congurations
AA
AA
C C BB
AA
AA B B
B
B
A
A
Use Dual row end feet at “A” locations.
Use Single row center foot at “B” locations, facing the
desks.
Use Dual row end feet at “A” locations.
Use a Dual row center foot at the center location, “B.”
4-Pack
Herringbone
H-Shape
C-Shape
AA
A
A
B

M5x10 Flat head screw
(qty 6)
120-Degree foot
(qty 3)
3mm Allen wrench
Height setting for
V2-Commercial Frames
Height setting for
V2 Frames
Step 1
The posts are designed with recommended height
setting indicator lines on the Bottom post for UPLIFT
V2 and UPLIFT V2-Commercial desks. Using the in-
cluded 3mm Allen wrench, loosen the the two M6x6
Set screws so the Upper post can slide.
If you are using the Power and Data Rail with UPLIFT
V2-Commercial desks, slide the Upper post until the
bottom edge is aligned with the rst indicator line.
For UPLIFT V2 frames, slide the Upper post to the
second indicator line.
Once in place, tighten the Set screws again and con-
tinue this process with the rest of your posts.
Step 2
Using six M5x10 Flat head screws, attach the 120-De-
gree feet (two screws per foot) as shown to the bot-
tom of each post assembly.
Hand tighten each screw a few turns at rst. Once all
screws are started, tighten them with the included
3mm Allen wrench.
Parts needed for this part of the assembly
120-Degree Post Assembly
M6x6 Set screw
(installed in post)
Comes pre-assembled
Consists of:
Upper post
Inner sleeve
(inside)
Bottom post
120-Degree Post
UPLIFT V2 Desks
UPLIFT V2-Commercial Desks

10
Step 3
Each 120-Degree post is used with three Square posts
in 3-Pack and Dog Bone Shape congurations. Once
the posts for a 3-Pack conguration are assembled,
position them as shown to the left approximately
where they will be located once the Power and Data
Rail assembly is complete.
Power infeeds can be introduced through the 120-De-
gree post or any of the Square posts. Locate the pow-
er infeed post close to the power outlet (for plug-in
power infeeds) or the junction box (for hardwire pow-
er infeeds) with the Power infeed hole facing the pow-
er source.
If you are assembling a Dog Bone Shape congura-
tion, you will need two sets of 120-Degree and Square
posts. Note, in a Dog Bone conguration using UP-
LIFT V2 Desks, two of the Square posts will need to
have Dual row center feet (see circled). If the desks
being used are not UPLIFT V2 Desks, we recommend
using Dual row end feet like the other posts.
Position the posts as shown to the left and approxi-
mately where they will be located once the Power and
Data Rail assembly is complete.
After the posts for either conguration are assembled
and located where they need to be, move on to at-
taching your rails.
Dog Bone Shape Conguration
3-Pack Conguration
Tabla de contenidos
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario











