United Security Products AVD-45 Guía rápida

United Security Products
Model AVD-45b
Automatic Voice Dialer
Installation and Instruction Manual
Patents
Pending

-
2
-
Thank you for purchasing United Security Products Model AVD-45b, the single
channel voice dialer that can be incorporated into hard wired or wireless security
systems or used as a stand-alone unit. This versatile dialer can be easily expanded to
operate in conjunction with an alarm, temperature or water level sensor, or any other
sensor that can provide the appropriate trigger.
The AVD-45b is compatible with continuous, momentary, normally closed (NC)
and normally open (NO) dry contact or voltage sensors. It can be programmed to
sequentially dial any combination of four standard telephone, most cellular telephones,
alpha/voice pagers and/or numeric pagers. The dialer features busy-line and no answer
detection to ensure timely transmission of the recorded message of up to 16 seconds.
This manual describes how to set up, install and operate the AVD-45b. Please read
the entire booklet before operating the dialer. For specific questions or problems,
contact a USP Technical Service Representative at (858) 597-6677, Monday –Friday,
7:30 AM -4:00 PM, Pacific Standard Time.
Package Contents
??Model AVD-45b Automatic Voice Dialer
??7-foot, 2-conductor jacket telephone cable with RJ11 plug attached
??7-foot jacketed, 4 conductor power/alarm cable
INTRODUCTION

-
3
-
987
P
*
RM
0#
4
1
5 6
2 3
AVD-45b
Automatic Voice Dialer
AVD
-
45b PANEL DISPLAY
9V ALKALINE
BATTERY
LCD
Speaker
MIC
Keypad
Mode
Program/
Pause
TEL LINE
12V
STANDBY
BATTERY
RED
BLACK
YELLOW
WH
ITE
12V
ALARM
+
-
REAR VIEW
BACK VIEW
FRONT VIEW

-
4
-
N.C./N.O. DRY CONTACT ACTIVATION HOOKUP
PP
-
1
STANDBY
BATTERY
(optional)
PANEL OR SENSOR
NC, NO, MOMENTARY, OR
CONTINUOUS ALARM
ACTIVATION
12VDC
+
-
ALARM
RED
BLACK
YELLOW
WHITE
RED
GREEN
TEL LINE
Make sure unit is set to “OFF” prior
to wiring and phone line hook-up.
Notes:
1. In momentary mode the dialer automatically dials all numbers
even after the alarm input is restored to non-
alarm. To stop dialing
you must press the M button to switch the unit to the OFF mode.
2. In continuous mod
e the alarm condition must be maintained for
the dialer to complete it’s dialing cycle (typically 7 minutes).
Dialing stops when the alarm input is restored to non-
alarm or by
pressing the M button.
3. Match the power cables colored wires to the corresponding
outputs on the alarm panel. Do the same for the telephone cable.

-
5
-
VOLTAGE LEVEL ACTIVATION HOOKUP
WHEN THE ALARM OUTPUT VOLTAGE IS RELAY DRIVEN, YOU MUST ADD A 1K RESISTOR
ACROSS ALARM OUTPUT TERMINALS. HOOK UP DIALER AS SHOWN BELOW.
PP
-
1
STANDBY
BATTERY
(optional)
ALARM CONTROL
PANEL
W/VOLTAGE TRIGGER
ALARM OUTPUT
12VDC
+
-
ALARM
+
-
INSTALL 1K OHM
RESISTOR HERE IF
ALARM OUTPUT IS
RELAY DRIVEN
1K
Make sure unit is set to “OFF” prior
to wiring and phone line hook-up.
Match the power cables colored wires to the corresponding
outputs on the alarm panel. Do the same for the telephone
cable.
RED
BL
ACK
YELLOW
WHITE
RED
GREEN TEL LINE
Alarm when voltage goes
from 0 to +V (5 to 28Vmax).
Program for N.C. operation.
Alarm when voltage goes
from +V (5 to 28Vmax) to 0.
Program for N.O. operation.
Note
: You may either program for momentary or
continuous voltage activation. In continuous mode, make
sure that t
he alarm condition is maintained for minimum 7
minutes to allow all numbers to be dialed. Pressing the M
button immediately resets the dialer.

-
6
-
IMPORTANT: Before operating the AVD-45b, make sure wiring is correct and
power is set within specified limits. Recording and data recall can be performed
without connection to a telephone line. We strongly recommend that final testing be
performed under simulated alarm conditions, and that confirmation of transmission
be obtained from the numbers dialed.
Model AVD-45b stores and dials up to 4 telephone numbers and/or pager numbers. Each
number may contain up to 28 digits, including a maximum of 10 “pause” segments (a pause is 2
seconds long and counts as a digit) and an optional “pound” tone for pager dialing.
Once a connection is made, the dialer will deliver a recorded voice message of up to 16 seconds
or a numeric code for pager messaging. The dialer will repeat the voice message two times per call,
to ensure that a full message is delivered. If the phone number is busy or not answered within 8 rings,
the AVD-45b will automatically dial the next programmed number.
Assuming an uninterrupted alarm (a minimum 7 minutes if programmed in continuous mode),
the dialer will go through the numbers a second time, and call in an attempt to deliver the message
twice to each programmed number. It will automatically call a pager # twice. If any numbers are busy
or unanswered, the dialer will continue calling (up to 10 times per programmed number) in an attempt
to deliver the voice message or until the alarm condition is terminated. In the TEST mode only, the
respective location numbers and telephone numbers will appear in the LCD to show the calls are in
process.
NOTE: If any numbers are used for alpha/voice pager designations that require operator assistance, the pager service
should be notified, to ensure proper interpretation of the message.
PROGRAMMING THE DIALER

-
7
-
How to store phone numbers
Follow these directions to store up to 4 telephone numbers in the dialer’s memory. Please remember
that local ordinances may prohibit automatic dialing of police, fire departments and other emergency
agencies.
The AVD-45b will call up to 4 numbers. This can be any combination of regular telephones, cellular
telephones or pagers. The 4 numbers being called will be stored in locations 1-4. Any of locations 1-4 can
store up to 28 digits and dial a telephone or pager. If dialing less than 4 numbers, simply leave the latter
location(s) empty and the unit will automatically skip them.
To program telephone numbers:
1. Supply power to the AVD-45b.
2. The AVD-45b has four modes (PROGRAM, TEST, OPERATE, and OFF) indicated in the upper part of
the LCD. Make sure the unit is in the “PROGRAM” mode. If it is not, press the MODE (“M”) button to
change modes.
To store “voice” telephone numbers in memory locations 1 through 4 (see p. 9 for pagers)
1. At the “PROGRAM: NUMBERS” prompt, press “1” (YES).
2. Press all the digits of the first number to be dialed. Check the LCD while programming to make sure the
correct numbers are pressed.
3. After inputting the entire phone number (1 + area code if needed), press the PROGRAM/PAUSE (“P”)
button (momentarily), then the “1” key. This will store the number in location 1.
4. Repeat step 1, then press all the digits for the second number to be dialed. Check the LCD, press the
PROGRAM/PAUSE (“P”) button (momentarily), then the “2” key. This will store the number in location
2.
5. Repeat the process, if needed, for locations 3 and 4.
NOTE: Multiple pauses are used when dialing a pager or cell phone, in which case during the
OPERATE mode the stored voice message will be played.
PROGRAMMING THE DIALER

-
8
-
PROGRAMMING THE DIALER
Example 1: Store telephone number 1-800-555-1212 in Location 1.
Press:
Example 2: Store telephone number 555-1212 in Location 2.
Press:
Follow the steps above to store the desired numbers in Memory Locations 3 and 4.
Note: If you enter the wrong number or wish to change a programmed number, press the
MODE (“M”) button until “PROGRAM: NUMBERS” prompt appears, enter “1” (YES)
and enter the number then the location (see example 1 or 2 above).
To completely erase numbers already stored in memory locations:
1.Set dialer to “PROGRAM: NUMBERS” prompt.
2.Press “1” (YES).
3.Press PROGRAM/PAUSE (momentarily).
4.Press the number (1,2,3 or 4) for the memory location to be erased.
1
8
0
0
5
5
5
1
2
1
2
P
1
Program/Pause
(Press momentarily)
5
5
5
1
2
1
2
P
2
Program/Pause
(Press momentarily)

-
9
-
To store a pager number and numeric code
1. With the dialer at the “PROGRAM: NUMBERS” prompt, press “1” (YES).
2. Enter all the digits of the pager number to be dialed. Check the LCD to insure the correct numbers
are pressed.
3. After inputting the entire pager number (1 + area code if needed), press the PROGRAM/PAUSE
(“P”) button and hold it down for about 2 seconds. A “P” will appear in the LCD following the
number. If more pauses are required, simply repeat the process by releasing the “P” button and
pressing it again for 2 seconds. Up to 10 pauses are allowed.
4. After the pause sequence, input the numeric code to be delivered. This is the code that will be
displayed on the pager. (Note: Some pager services require a “#” sign at the end of the numeric
message for proper transmission. Also make sure that the total length of the number including
pauses and “#” does not exceed 28 characters).
5. Finally, press the PROGRAM/PAUSE (“P”) button (momentarily), then the “1” key. This will
store the number, pauses and the numeric code in location 1.
6. Repeat step 1, then press all the digits for the second pager number to be dialed. Check the LCD,
input pause(s), input the numeric code, then press the PROGRAM/PAUSE (“P”) button
(momentarily) and the “2” key. This will store the number in location 2.
7. Repeat the process, if needed, for locations 3 and 4.
8. You may store pager number and numeric code in any memory location (1-4).
9. When testing the pager operation, it is recommended that the AVD-45b be in the “OPERATE”
mode, connected to a phone line and the input triggered.
NOTE: A pause counts as one digit. Up to 10 pauses are allowed.
PROGRAMMING THE DIALER

-
10
-
PROGRAMMING THE DIALER
Example 1: Store pager number 555-1212 and numeric message
911 in Location 1.
Press:
Example 2: Store pager number 1-800-555-1212 with access code 3
and numeric message 911 in Location 2.
Press:
Note: If you enter the wrong number or wish to change a programmed number, press
the MODE button until “PROGRAM: NUMBERS” prompt appears, enter “1” (YES)
and enter the number then the location (see example 1 or 2 above).
5
5
5
1
2
1
2
P
9
1
1
P
1
Program/Pause
(Press momentarily)
1
8
0
0
5
5
5
1
2
Program/Pause
(Hold for 2 seconds)
Program/Pause
(Hold for 2 seconds)
1
2
P
3
#
9
1
1
#
P
2
Access
Code
Enter if required by provider Program/Pause
(Press momentarily)
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Sistema de seguridad de United Security Products
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario