U.S. Solid USS-DBS01 Series Manual de usuario

Instruction Manual
U.S. Solid Mobile-controlled
Analytical Balance

1
Table of Contents
Normal Operation
I. Getting Started............................................................................................................ 2
II. Specifications.............................................................................................................5
Technical Parameters:............................................................................................. 5
III. Unit Transformation................................................................................................. 6
IV. Panel Description......................................................................................................7
Panel Explanations.................................................................................................. 7
V. Installation..................................................................................................................8
Choosing the installation location...........................................................................8
Unpacking and inspection....................................................................................... 9
VI. Using the Balance.................................................................................................. 10
Level adjustment................................................................................................... 10
Start....................................................................................................................... 10
Calibration............................................................................................................. 10
Tare function..........................................................................................................11
Weighing unit selection......................................................................................... 11
Counting................................................................................................................ 11
VII. Maintenance and Cleaning................................................................................... 12
Cleaning.................................................................................................................13
Troubleshooting Guide.......................................................................................... 13
Mobile App Operation
Home............................................................................................................................ 16
Connect Device...................................................................................................... 16
1. Discover......................................................................................................16
2. Connected...................................................................................................17
Weight records...................................................................................................... 18
Settings..................................................................................................................18
1. Language.................................................................................................... 18
2. Data Storage............................................................................................... 19
3. Weighing Settings.......................................................................................20
4. Software Version........................................................................................ 21
Functions...................................................................................................................... 22
Basic.......................................................................................................................22
Statistics................................................................................................................ 24
Percent...................................................................................................................27
Density...................................................................................................................28
Multi-device...........................................................................................................31
Settings..................................................................................................................33
1. Sensitivity...................................................................................................33
2. Calibration..................................................................................................33
Tare...............................................................................................................................35
Zero.............................................................................................................................. 35
Switch...........................................................................................................................35

2
I. Getting Started
Thank you for choosing U.S. Solid USS-DBS01 Series Mobile-controlled
Analytical Balance. We hope you enjoy your purchase. Please use and
maintain the equipment according to all instructions within the manual.
The U.S. Solid Mobile-controlled Analytical Balances innovatively enable
app-controlled function on the basis of normal operating mode, which
means you can now connect and control your U.S. Solid analytical
balance with mobile device. We believe this new feature will improve
our users’ experience, with minimum extra cost.
*Note: Please download U.S. Solid Balance app in App Store (IOS) or
Google Play Store (Android) before using.
This product was developed according to CE marking regulations while
emphasizing aesthetics and safety for the user. It has ISO certification,
specifically ISO 9001 The high quality of the product, coupled with
proper user care, should allow you to enjoy the product for years.
Improper use of this equipment can cause accidents, including but not
limited to: electric discharges, circuit breaker malfunctions, fire, etc.
Please read the maintenance section, where this is explained more fully.
For best results and longevity in product efficiency, read through this
manual thoroughly before using the product.
Please bear in mind the following:

3
·This manual should be kept with the analytical balance, so it is
available to all users
·Be careful when handling the balance. Avoid any sudden movements
when in its vicinity. Be sure to not drop the balance, nor drop any
heavy/sharp objects on it. Keep liquids away from the balance to avoid
spills.
·Never take apart the balance to try and fix yourself. This could ruin the
entire balance, and voids the product warranty. There is also risk of
injury when disassembling the balance.
·To prevent fire and electrical issues, avoid dusty or overly dry
environments. In case of electrical issue or fire, unplug the balance
immediately.
·During setup, installation, and use, contact your wholesaler with any
questions that arise.
·This equipment is protected under the Warranties and Consumer
Good Regulation (10/2003)
·Overhaul is not covered by the equipment warranty
·Changes made to the product by non-certified individuals will result in
a loss of the product warranty
·Accessories, including their loss, are not covered by the product
warranty, nor does the warrant cover piece ’ s deterioration over the
course of time.
·Keep your invoice, either for having the right to a warranty, or for
asking for warranty coverage. Manufacturer reserves the right to modify
or improve the manual or equipment.

4
Always make sure you calibrate your scale before using
Features:
·Bluetooth connection function
·Electromagnetic force compensation technology
·Aluminum alloy die cast base and ss platter
·Super bright 5 inch color LCD display with backlight
·Touch screen
·Height-adjustable feet
·RS232 interface
·Full capacity taring
·Overload protection,bubble level adjustment ,under hook
·Different units of measure: g, lb, ct, oz, gn, ozt, dwt, dr, MM, tl. J, tl.T,
tl.H, tola
·Check Weighing

5
II. Specifications
Technical Parameters:
MODEL
USS- DBS01002
USS- DBS01003
Max Capacity in
grams
120 g
200 g
Accuracy Class
I
Min. Capacity
10 mg
Division
0.0001 g
Verification Scale
Value
0.001g
Repeatability
±0.0002 g
Linearity
±0.0003 g
Stabilization Time
≤8 Seconds
Operating
Temperature
17.5°C- 22.5°C, with fluctuations of <1°C/Hour
63.5°F- 72.5°F with fluctuations of <1.8°F/ Hour
Relative Humidity
50%-75%
Pan size
Ф90 mm
Windshield
225 x 220 x 265 mm (L*W*H)
Total dimensions
355 x 230 x 350 mm(L*W*H)
Net weight
7.2 kg
Power
AC 110 - 240 V 50 Hz/60 Hz
DC 9 V-2.2 A by using the universal adapter

6
III. Unit Transformation
Unit
Conversion
Rate
Digit after
Decimal Point
g
1
4
mg
1000
1
lb
0.0022046
6
ct
5
3
oz
0.035274
5
gn
15.4323584
3
ozt
0.0321507
5
dwt
0.6430149
4
dr
0.5643834
4
MM
0.266666951
4
tl.J
0.02671725
5
tl.T
0.026666702
5
tl.H
0.026455464
5

7
IV. Panel Description
Panel Explanations
1. Language: Switch between Chinese and English
2. Time:Set time
3. INT: Press ”+”or “-”to choose the speed
INT-0 Highest Speed
INT-1 High Speed
INT-2 Normal Speed
INT-3 Low Speed
4. PCS: Press it to enter the piece counting mode
5. ASD: Press ”+” or “-” to choose the sensitivity to match the
environment
ASD-0 The highest sensitivity
ASD-1 The high sensitivity

8
ASD-2 The normal sensitivity
ASD-3 The poor sensitivity for bad environment
6. Print: Press”+”or “-”to choose the print
mode
PRN-0 Output by Pressing
PRN-1 Timing output for every 30s
PRN-2 Timing output for every 60s
PRN-3 Timing output for every 120s
PRN-4 Continuous output
7. EXT CAL:Calibration key
V. Installation
Choosing the installation location
When analytical balances are used in routine lab or industrial
measurement environments, the weighing speed will be much
quicker, and the results more accurate. The location should meet the
following conditions:
1. Work room should be clean and dry
2. Balance should be placed on a solid, stable, plain flat surface
3. Avoid locations in which the balance could be exposed to any of the
following:

9
a. Airflow from air conditioners, fans, doors, or windows
b. Vibrations from surrounding or nearby equipment
c. Direct sunlight or radiation
4. Do not use the balance anywhere exposed to explosive,
combustible, or corrosive gases.
5. Do not use the balance in areas with high humidity or high levels of
dust
6. When moving from a cooler to a warmer place, the accuracy and
reliability of the scale will be influenced by the moisture
condensation inside the balance. In order to eliminate this
influence, it is best to leave the scale unplugged in its new location
for at least two hours before next use.
7. Keep the balance clean.
8. Do not leave material on the balance when not in use.
Unpacking and inspection
Check that all of the items indicated below are included in the package
and that nothing has been damaged:
·Balance
·Pan
·Power Cable
·External Calibration weight
·Manual
In case the balance or any component is damaged during transport,
tell your transportation agent immediately in order to process claims
within the proper time frame.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Escala de U.S. Solid

U.S. Solid
U.S. Solid USS-DBS86 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS91 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS93 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS81 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS82 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS83 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS49 Manual de usuario

U.S. Solid
U.S. Solid 1004 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS3-1 Manual de usuario

U.S. Solid
U.S. Solid USS-DBS Series Manual de usuario