turck TBIL-M1-16DIP Manual de usuario

Your Global Automation Partner
Instructions for Use
TBIL-M1-16DIP
I/O-Hub with IO-Link

2Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

V01.00 | 2020/11 3
Table of Contents
1 About These Instructions.................................................................................................................. 5
1.1 Target groups................................................................................................................... 5
1.2 Explanation of symbols used ........................................................................................ 5
1.3 Additional documents.................................................................................................... 5
1.4 Feedback about these instructions.............................................................................. 5
2 Notes on the Product......................................................................................................................... 6
2.1 Product identification..................................................................................................... 6
2.2 Product identification..................................................................................................... 6
2.3 Scope of delivery ............................................................................................................. 6
2.4 Legal requirements.........................................................................................................6
2.5 Manufacturer and service.............................................................................................. 6
3 For Your Safety.................................................................................................................................... 7
3.1 Intended use..................................................................................................................... 7
3.2 General safety notes ....................................................................................................... 7
4 Product Description ........................................................................................................................... 8
4.1 Device overview .............................................................................................................. 8
4.1.1 Display elements.............................................................................................................................. 8
4.2 Properties and features.................................................................................................. 8
4.3 Functions and operating modes ..................................................................................8
5 Installing............................................................................................................................................... 9
6 Connecting ........................................................................................................................................10
6.1 Connecting the supply voltage and IO-Link ............................................................10
6.2 Connecting digital sensors..........................................................................................10
7 Parameterizing and Configuring...................................................................................................11
7.1 Parameters......................................................................................................................11
7.2 System commands ........................................................................................................12
8 Operating ...........................................................................................................................................13
8.1 LED displays....................................................................................................................13
8.1.1 IO-Link................................................................................................................................................13
8.1.2 Channel-LEDs ..................................................................................................................................13
8.2 IO-Link events ................................................................................................................13
8.3 IO-Link error codes........................................................................................................14
9 Troubleshooting ...............................................................................................................................15
10 Maintenance......................................................................................................................................16
11 Repair..................................................................................................................................................16
11.1 Returning devices..........................................................................................................16
12 Disposal ..............................................................................................................................................16
13 Technical Data...................................................................................................................................17
14 Appendix: EU Declaration of Conformity ....................................................................................19

Table of Contents
4Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

V01.00 | 2020/11 5
1 About These Instructions
These operating instructions describe the structure, functions and the use of the product and
will help you to operate the product as intended. Read these instructions carefully before using
the product. This is to avoid possible damage to persons, property or the device. Retain the in-
structions for future use during the service life of the product. If the product is passed on, pass
on these instructions as well.
1.1 Target groups
These instructions are aimed at qualified personal and must be carefully read by anyone
mounting, commissioning, operating, maintaining, dismantling or disposing of the device.
1.2 Explanation of symbols used
The following symbols are used in these instructions:
DANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if
not avoided.
WARNING
WARNING indicates a dangerous situation with medium risk of death or severe in-
jury if not avoided.
CAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor
or moderate injury if not avoided.
NOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.
NOTE
NOTE indicates tips, recommendations and useful information on specific actions
and facts. The notes simplify your work and help you to avoid additional work.
uCALL TO ACTION
This symbol denotes actions that the user must carry out.
aRESULTS OF ACTION
This symbol denotes relevant results of actions.
1.3 Additional documents
The following additional documents are available online at www.turck.com
nData sheet
nEU Declaration of Conformity
nCommissioning manual IO-Link devices
1.4 Feedback about these instructions
We make every effort to ensure that these instructions are as informative and as clear as pos-
sible. If you have any suggestions for improving the design or if some information is missing in
the document, please send your suggestions to [email protected].

Notes on the Product
Manufacturer and service
6Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
2 Notes on the Product
2.1 Product identification
This instruction is valid for following devices:
nTBIL-M1-16DIP
2.2 Product identification
2.3 Scope of delivery
The scope of delivery includes:
nI/O hub
nDummy plugs for M12-connectors
nLabel clips
2.4 Legal requirements
The device falls under the following EU directives:
n2014/30/EU (electromagnetic compatibility)
n2011/65/EU (RoHS Directive)
2.5 Manufacturer and service
Hans Turck GmbH & Co. KG
Witzlebenstraße 7
45472 Mülheim an der Ruhr
Germany
Turck supports you with your projects, from initial analysis to the commissioning of your applic-
ation. The Turck product database contains software tools for programming, configuration or
commissioning, data sheets and CAD files in numerous export formats. You can access the
product database at the following address: www.turck.de/products
For further inquiries in Germany contact the Sales and Service Team on:
nSales: +49 208 4952-380
nTechnology: +49 208 4952-390
Outside Germany, please contact your local Turck representative.

V01.00 | 2020/11 7
3 For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1 Intended use
These devices are designed solely for use in industrial areas.
The block module TBIL-M1-16DIP is an O-Link device (Class A) and serves as I/O hub between
field devices (sensors) and the IO-Link master. The hub has 16 digital inputs. The device is de-
signed in IP65/IP67/IP69K and can be mounted directly in the field.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
3.2 General safety notes
nThe device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
nThe device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
nThe device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.

Product Description
Functions and operating modes
8Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4 Product Description
The I/O hub TBIL-M1-16DIP connects up to 16 digital sensors with one IO-Link master port.
Eight M12 connectors are available for connecting the field devices. The I/O hub is connected
to the IO-Link master via an M12 socket. The devices are designed in a fully encapsulated hous-
ing with degree of protection IP65/IP67/IP69K.
4.1 Device overview
C1 C3
C2 C4
C5
C6
C7
C8
73
107
44,7 32,2
150
16 25,2
ø 4,3
54
M12 x 1
27,4
Fig.1: Dimensions
4.1.1 Display elements
The device has the following LED indicators:
nIO-Link communication
nI/O status
4.2 Properties and features
nFibre-glass reinforced housing
nShock and vibration tested
nFully potted module electronics
nProtection class IP65/IP67/IP69K
nIO-Link diagnostics for short-circuit and supply over- and undervoltage
n2 universal digital channels per connector
nMetal connectors
4.3 Functions and operating modes
The I/O hub TBIL-M1-16DIP connects up to 16 digital sensors with one IO-Link master port.
The device provides diagnostics for power supply and short circuit of the sensors and actuators
on the IO-Link master.

V01.00 | 2020/11 9
5 Installing
The device is mounted via four M4 screws on a flat and pre-drilled mounting surface.
Fasten the module to the mounting surface with 4 M4 screws. The maximum tightening
torque for the screws is 0.5 Nm
107
34
32.2 - 44.7
M4 (4 x)
max. 0.5 Nm
Fig.2: Mounting the device to a mounting plate

Connecting
Connecting digital sensors
10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
6 Connecting
6.1 Connecting the supply voltage and IO-Link
The devices provide a 5-pin M12 connector for the connection to IO-Link.
Fig.3: M12 connector for the connection to IO-Link
Connect the device to power supply IO-Link according to the pin assignment below.
6.2 Connecting digital sensors
For connecting digital sensors, 5-pin M12 connectors are available.
Fig.4: M12 connector for connecting digital sensors (C1…C8)
Connect the sensors to the device according to the pin assignment.
5 FE 4 BK
1 BN +
3 BU –
3 BU –
2 WH
v
C1...C8
Fig.5: Pin assignment TBIL-M1-16DIP (C1…C8)
Supply sensors externally
sensors which are supplied externally can also be connected to the TBIL I/O hubs. When sensors
are supplied externally, the following safety regulations have to be observed:
Supply sensors from SELV or PELV power supplies.
Decouple external circuits that are not designed as SELV or PELV systems by opto-
couplers, relays or other measures.
Tabla de contenidos
Otros manuales de Cambiar de turck

turck
turck TBIL-M1-16DXP Manual de usuario

turck
turck TBIL-S Series Manual de usuario

turck
turck TBEN-L SE-M2 Series Manual de usuario

turck
turck TBIP-L 16DXP-AUX Series Manual de usuario

turck
turck TBEN-L-SE-U1 Series Manual de usuario

turck
turck TBIL-S Series Manual de usuario

turck
turck FMX-IM-3UP63X Manual de usuario

turck
turck IM1-451EX Series Manual de usuario