Trotec B6E Manual de usuario

TRT-BA-B6E-TC2017-60-005-EN
B 6 E
EN
OPERATING MANUAL
HUMIDIFIER

2 EN
humidifier B 6 E
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................5
Assembly and installation.....................................................6
Operation ...............................................................................9
Available accessories..........................................................11
Errors and faults..................................................................12
Maintenance ........................................................................13
Technical annex...................................................................18
Disposal ...............................................................................18
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
B 6 E
https://hub.trotec.com/?id=41496
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Do not expose the device to directly squirting water.
• Fill the device with fresh drinking water only.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.

EN 3
humidifier B 6 E
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Do not use the device when the water tank is empty.
• Before filling the water tank, switch the device off and
disconnect the power cable from the mains socket. Hold
onto the mains plug while doing so.
• Only transport the device in an upright position with an
emptied water tank.
• Empty the water tank before transport and storage. Do not
drink the water. Health hazard!
• Note that high humidity levels may enhance the growth of
biological organisms in the environment.
• Make sure that objects in the surroundings of the device
do not become wet or damp. If moisture is present, the
output must be reduced. If the output cannot be reduced,
the device must only be operated in intervals. Absorbent
materials such as carpeting, curtains, sheers or tablecloths
must not become damp.
• Make sure that the water in the water thank is replaced
every3days. Otherwise there is a risk of microorganisms
growing in the water tank which presents a health hazard
if they get into the air or water.
Intended use
Only use the device B 6 E as a mobile humidifier for the
humidification and filtration of room air, while adhering to and
following the technical data.
Intended use comprises humidifying the room air in:
• living spaces
• warehouses and archives
• libraries
• call centres and computer rooms
Improper use
The device is not intended for industrial use.
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.

4 EN
humidifier B 6 E
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Symbols Meaning
This symbol located on the device indicates that
the filter has to be checked and, if necessary, to
be cleaned prior to each operation. Replace the
filter if it is defective.
Do not insert a wet filter into the device. Wait until
the filter has dried.
Symbols Meaning
This symbol located on the device indicates that
the water tank should be cleaned every3days.
Change the water in the water tank every3days.
Disconnect the device from the mains before
cleaning the water tank.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Caution
If the device is knocked over, water will leak from the
lower part.
Disconnect the device from the mains to prevent
damage to the device caused by dry running.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device B 6 E functions as a humidifier, aroma diffuser and
air cleaner.
The ultrasound technology ensures a pleasant room climate and
air quality improvement.
The device is equipped with an integrated scented oil tank and
diffuser for optional room air aromatization.
The on-demand ionization function promotes the removal of
harmful substances and odours from the room air.
The device comes with an automatic mode and a night mode.
Moreover, a timer can be programmed for automatic switch-off
after 1 to 12hours.
The capacity of the water tank allows for a runtime of up
to 16hours.
The device switches off automatically when the water tank is
empty.

EN 5
humidifier B 6 E
Device depiction
2
1
3
11
12
4
5
6
8
9
10
7
No. Designation
1 Mist nozzle
2 Water tank
3 Bottom section
4 Water tank transport handle
5 Carbon filter
6 Filter cartridge with water softener
7 SecoSan® Stick 10 (optional accessory)
8 Brush
9 Scented oil tank with sponge
10 Water tank filling level indication
11 Control panel
12 Display
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Before transporting the device, observe the following:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the water tank.
• Do not use the power cable to drag the device.
• Check whether the upper part is correctly positioned on
the lower part.
• Lift the device at the lower part.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.

6 EN
humidifier B 6 E
Storage
Before storing the device, observe the following:
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the water tank.
• Empty the lower part.
• Use a cloth to wipe all parts of the device dry.
• Clean the device according to the Maintenance chapter.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
• 1x Device
• 1x Water softener
• 1x Brush
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only put up the device in an upright, stable position on firm
ground.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are unrolled completely.
• Make sure that there are no moisture-sensitive objects
located in the immediate vicinity of the mist nozzle, since
water may condense near the mist nozzle.
Filling the water tank
The water tank should be filled before first use or when the
lacking water indication(16) lights up.
Note
Fill the device with fresh drinking water only. The
water temperature must not exceed 40°C.
Scented oil or other additives can damage the plastics
and the nebulizer membrane.
Info
If possible, change the water every3days to prevent
bacterial growth.
1. Remove the mist nozzle(1) from the water tank.
2. Remove the water tank(2) from the device by lifting the
water tank at the transport handle(4).
Note that there may still be residual water left in the lower
part(3) if the device was used beforehand.
321
4
3. Turn the water tank over. Please note that the opening at
the transport handle must not be used to fill the tank! It is
the outlet for the water mist.

EN 7
humidifier B 6 E
4. Unscrew the fuel tank cap(13).
13
6
5. Fill fresh drinking water (approx. 5l, maximally 40°C) into
the water tank.
6. Insert the SecoSan® Stick (optional accessory)(7) into the
water tank(1).
7. Screw the tank lid(13) firmly back onto the water tank(2).
6
13
8. Refit the water tank(2) into the device.
ðWhen doing so, make sure that the water tank is
correctly inserted in the guide.
ðPlease note that after inserting the water tank, the
water immediately starts to run into the bottom of the
device.
9. Refit the mist nozzle(1) onto the water tank(2).

8 EN
humidifier B 6 E
Scent option
Additionally, the device offers the possibility to distribute a scent
during operation.
Note
Never put scented oil directly into the scented oil tank,
the water tank or on the membrane. Direct contact
with scented oil might cause damage to plastic
components or other device parts.
Use standard scented oil. Proceed as follows to use the scent
option:
üThe device is switched off and the power cable is
disconnected from the mains.
1. Remove the scented oil tank(9) from the device.
9
2. Put 2 to 3drops of scented oil onto the sponge in the
scented oil tank(9)
3. Push the scented oil tank(9) back into the device.
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.
• The power indication(18) lights up and an acoustic
confirmation signal is emitted.

EN 9
humidifier B 6 E
Operation
• Avoid open doors and windows.
Display
14
16
18
17
19
21
22
15
20
No. Designation Description
14 Room humidity segment
display
Indicates the current relative
room humidity
Indicates the desired relative
room humidity during setting
15 Hours segment display Indicates the number of hours
during timer programming
16 Standard indication Illuminated when
humidification mode is
activated
17 Lacking water indication Displayed when the water tank
is empty or not installed
correctly
18 Power indication Illuminated when the mains
plug is connected
Illuminated during ongoing
operation
19 Nebulizer intensity
indication
Indicates the selected
nebulizer intensity during
setting
20 Anion indication Illuminated when ionization is
activated
21 iItelligent indication Illuminated when automatic
mode is activated
22 Sleep indication Illuminated when night mode is
activated
Operating elements
23 24 25 26
28 27
No. Designation Description
23 Mode button Setting the operating mode:
standard = manual
humidification
intelligent = automatic mode
sleep = night mode
24 Humidity button Setting the relative room
humidity
25 Timer button Switching the timer function on
or off
26 On/Off button Power button:
Switching the device on or off
27 Arrow right button Increasing the nebulizer
intensity
28 Arrow left button Decreasing the nebulizer
intensity
Switching the device on
1. Make sure that the tank has been filled with drinking
water.
2. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
3. Press the On/Off button(26).
ðThe device starts to humidify. Fine water mist leaves the
mist nozzle(1).
4. You can rotate the mist nozzle(1) 360° to adjust the outlet
direction of the water mist.

10 EN
humidifier B 6 E
Controlling humidification
The desired room humidity can be set to 40%, 50%, 60 %,
70 %, 80 % or OL (continuous humidification regardless of the
room humidity).
The desired room humidity can only be set in manual
humidification mode.
1. Press the Humidity button(24) until the desired room
humidity is displayed.
ðThe desired room humidity flashes on the segment
display(14) for approx.5s.
ðThen, the current relative room humidity is shown on
the segment display(14) again.
ðThe desired relative room humidity is set.
Setting the nebulizer intensity
The nebulizer intensity can be set in all operating modes. The
default setting is level3.
The nebulizer intensity can be set to 6levels, with level1
corresponding to the lowest and level6 to the highest nebulizer
intensity.
1. Press the arrow buttons(27, 28) to set the desired
nebulizer intensity.
ðThe current nebulizer intensity is shown on the
nebulizer intensity indication(19).
ðThe desired nebulizer intensity is set.
Setting the operating mode
You can switch between the following operating modes:
• Manual humidification (standard indication, 16)
• Automatic mode (intelligent indication, 21)
• Night mode (sleep indication, 22)
1. To select the desired operating mode, press the Mode
button(23).
ðThe corresponding indication appears on the display.
Manual humidification
The device always starts in this operating mode. The current
room humidity and nebulizer intensity are shown on the display.
The desired relative room humidity can be adjusted at any time
in this operating mode. The setting options are 40%, 50%,
60 %, 70 %, 80 % or OL (continuous humidification regardless
of the room humidity).
The nebulizer intensity can be adjusted at any time in this
operating mode.
• If the current relative room humidity is lower than the
desired relative room humidity, the device humidifies the
air with the selected nebulizer intensity.
• If the current relative room humidity is equal to or higher
than the desired relative room humidity, the device
humidifies the air at nebulizer intensity level 1.
• If OL is selected, the device humidifies the air with the
selected nebulizer intensity regardless of the current
relative room humidity.
Automatic mode
The device humidifies the air constantly and regardless of the
relative room humidity.
The desired relative room humidity cannot be adjusted in this
operating mode.
The nebulizer intensity can be adjusted at any time in this
operating mode.
In automatic mode, the device operates with the following
settings:
• If the current relative room humidity is equal to or higher
than 60%, the device humidifies the air at nebulizer
intensity level 1.
• If the current relative room humidity is between 40% and
60%, the device humidifies the air with the nebulizer
intensity set.
Tabla de contenidos
Otros manuales de Humidificador de Trotec

Trotec
Trotec B 200 Manual de usuario

Trotec
Trotec AW 10 S Manual de usuario

Trotec
Trotec B 5 E Manual de usuario

Trotec
Trotec B 1 E Manual de usuario

Trotec
Trotec B 200 Manual de usuario

Trotec
Trotec B 25 E Manual de usuario

Trotec
Trotec B 3 E Manual de usuario

Trotec
Trotec AW 20 S Manual de usuario

Trotec
Trotec B 2 E Manual de usuario

Trotec
Trotec B 400 Manual de usuario