TRBOnet Swift A200 Manual de usuario

WorldHQ
NeocomSoftware
8th Line 29,Vasilyevsky Island
St. Petersburg, 199004, Russia
US Office
NeocomSoftware
15200 Jog Road,Suite 202
Delray Beach, FL 33446, USA
Internet
Email: info@trbonet.com
WWW.TRBONET.COM
Telephone
EMEA: +44 203 608 0598
Americas: +1 872 222 8726
APAC: +61 28 6078325
Radio-over-IP Gateway
TRBOnet Swift A200
User Manual

Notices
This document is for informational purposes only. Neocom software, Ltd offers no
warranties, express or implied, in this document.
Neocom and the Neocom logo, TRBOnet and the TRBOnet logo are either registered
trademarks or trademarks of Neocom software, Ltd.
MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M logo are trademarks
or registered trademarks of Motorola Trademark Holdings, LLC.
Microsoft, Windows, SQL Server and the .NET logo are either registered trademarks or
trademarks of Microsoft Corporation in the United States and/or other jurisdictions.
Other product or company names mentioned herein may be trademarks of their
respective owners.
© 2017 by Neocom software, Ltd. All rights reserved.
This document was last revised on November 7, 2017.

ii
Contents
1Introduction ........................................................................................................................................................1
1.1 About This Document.......................................................................................................................1
1.2 About TRBOnet Swift.........................................................................................................................1
1.3 Contacts..................................................................................................................................................1
2About Swift A200..............................................................................................................................................2
2.1 Features ..................................................................................................................................................2
2.2 Capabilities............................................................................................................................................2
2.3 Restrictions............................................................................................................................................3
2.4 Delivery Kit ............................................................................................................................................3
2.5 Design .....................................................................................................................................................4
2.6 Connectors ............................................................................................................................................5
2.7 LED Indication ......................................................................................................................................6
2.8 Acronyms ...............................................................................................................................................7
3Setup and Connection ....................................................................................................................................8
3.1 MOTOTRBO Mode .............................................................................................................................8
3.2 Non-MOTOTRBO Mode................................................................................................................16
3.3 Power Supply.....................................................................................................................................21
4TRBOnet Configuration ...............................................................................................................................23
4.1 TRBOnet Enterprise/PLUS Configuration................................................................................24
4.2 TRBOnet Watch Configuration ...................................................................................................27
5Maintenance....................................................................................................................................................29
5.1 Built-in Clock Battery Replacement ..........................................................................................29
5.2 Memory Card Replacement.........................................................................................................29

Introduction
1
1Introduction
1.1 About This Document
The information in this document is intended for engineers responsible for building
MOTOTRBO radio networks and programming two-way radios for end users.
The document describes in detail how to connect, set up, and maintain the TRBOnet
Swift A200 hardware radio-over-IP gateway.
1.2 About TRBOnet Swift
TRBOnet Swift is a family of hardware products designed by Neocom Software
Solutions, Ltd for MOTOTRBO radio networks. The Swift family hardware is presented
by RoIP gateways A001/002 and A200, the option board ST002, the data transfer
module DT500, and the GSM tracker TR001.
For more information about the TRBOnet Swift family products, refer to our website.
1.3 Contacts
Region Phone Email & Support
EMEA +44 203 608 0598 info@trbonet.com — general and
commercial inquiries
support
http://kb.trbonet.com — online
knowledge base
Americas +1 872 222 8726
APAC +61 28 607 8325

2TRBOnet Swift A200 – User Manual
2About Swift A200
TRBOnet Swift A200 is a hardware radio-over-IP gateway designed to interface your
TRBOnet Server to a MOTOTRBO or non-MOTOTRBO control (donor) radio, or a
MOTOTRBO repeater in the analog or digital mode.
2.1 Features
Compact size and light weight
Wireless and wired connection with control radios
Support for 10 connections with TRBOnet servers
Interfaces:
7 I/O contacts for external hardware (SCADA, sensors, and other)
USB interface for wired communication with MOTOTRBO control radios and
repeaters
NRF interface for wireless communication with a MOTOTRBO radio
Audio interface for wired communication with non-MOTOTRBO control
radios
LAN interface for the wired IP connection (Ethernet 10/100Base-T, 10/100
Mbit/s)
Micro-USB port for programming
12V DC power supply
OLED display
Support for flash cards with capacities up to 32 Gb
Quick and easy connection and setup
Unattended operation that does not require regular maintenance
2.2 Capabilities
A gateway between a radio channel and an IP network
A radio connected to Swift A200 can transfer voice and data to all connected
TRBOnet Servers over IP. Swift A200 performs no encryption of the transferred
voice and data traffic.
Remote control
TRBOnet control room operators can control a connected radio remotely by
sending commands (power on/off, channel and zone selection) over IP.
Self-check and alarm notification
Swift A200 performs continuous monitoring of all connections and physical
parameters (interior temperature, battery status). When an error is detected,
the device shows the corresponding information on the display and sends an
alarm notification to all connected TRBOnet Servers. The notification is
displayed on the screens of TRBOnet control room operators.

About Swift A200
3
2.3 Restrictions
1. Due to changes introduced by Motorola into recent MOTOTRBO firmware, we do
not recommend that you use Swift IP Gateways A001, A002 and A200 in the
wireless (NRF) mode in conjunction with MOTOTRBO radios that have firmware
version 2.60 and higher. The latest firmware that can be used in this mode is
2.05.60. The A200 Gateway can work with newer firmware in the wired (USB)
mode. Please do not update your control radios beyond this version number if you
have A001 or A002 in the wireless (NRF) mode.
2. Swift IP Gateways A001, A002 and A200 in the wireless (NRF) mode do not
support revert channels and data repeaters. The A200 Gateway in the wired (USB)
mode must be used instead.
3. We do not recommend to install any Swift IP Gateways in the same subnet as
trunked repeaters (applies to Capacity Plus and Linked Capacity Plus).
2.4 Delivery Kit
TRBOnet Swift A200 delivery kit includes accessories listed in Table 1.
Table 1: TRBOnet Swift A200 delivery kit
Item Description Quantity
TRBOnet Swift A200 A radio-over-IP gateway unit with a factory-installed
MicroSD card (4 Gb or more) and a CR1220 battery.
1
TRBOnet Swift Transfer ST002 An option board for a MOTOTRBO radio. 1
Flex cable A flex cable for connecting the option board to the
main board of a MOTOTRBO radio.
1
Micro-USB <> USB cable A programming cable. 1
USB <> RADIO cable A service cable for connecting a MOTOTRBO radio to
Swift A200.
1
Audio cable An audio cable (in and out) for connecting a non-
MOTOTRBO two-way radio to Swift A200.
1
Micro-Fit connector system A Micro-Fit plug and a wire kit for connecting Swift
A200 to a non-MOTOTRBO two-way radio, a 12V DC
power supply, and external hardware.
1
Screw kit 1
Passport 1

4TRBOnet Swift A200 – User Manual
2.5 Design
FRONT PANEL
OLED display that shows the connection status and self-check information.
Micro-USB port to connect the device to a computer using the programming
cable.
REAR PANEL
DC power inlet.
Audio Input and Audio Output to connect a non-MOTOTRBO two-way radio.
Micro-Fit 3mm pitch connector to connect a non-MOTOTRBO radio, a 12V DC
power supply, and external hardware.
LAN port.
USB port to connect a MOTOTRBO radio.
1
2
1
2
3
4
5

About Swift A200
5
2.6 Connectors
Table 2: I/O connector pinout
I/O Connector
Power (GND)
Input (IN7)
Input/output (IO6)
Input/output (IO4)
Input/output (IO2)
UART input, 5V (RX)
Power (+12V)
Output (OUT7)
Input/output (IO5)
Input/output (IO3)
Input/output (IO1)
UART output, 5V (TX)

6TRBOnet Swift A200 – User Manual
2.7 LED Indication
Table 3: LED icons
Icon State
Radio connection
Flashing icon: The radio is not connected or powered off.
Radio TX
Radio RX
IP connection
Digits near the icon: The number of connected TRBOnet servers.
Flashing icon: Swift A200 is not connected to an IP network.
Activity on the IP connection
Wireless connection to the radio
USB connection to the radio
Memory card
Flashing icon: The memory card is not detected.
Low battery charge
Flashing icon: Battery replacement is required.
Built-in clock not set
Flashing icon: The built-in clock is not set. Update of the device configuration or battery
replacement is required.

About Swift A200
7
2.8 Acronyms
This section lists all abbreviations used in this document.
Table 4: Acronyms
Acronym Description
AC Alternating current
CPS Customer Programming Software
Db Decibel
DC Direct current
Gb Gigabyte
GND Ground
GPIO Input/output Generic Pin
GSM Global System for Mobile Communications
I/O Input/output
IP Internet Protocol
LAN Local Area Network
LED Light-emitting diode
MAC Media Access Control
Mbit/s Megabit per second
Mbps Megabit per second
mm Millimeter
NRF Nordic RF
OLED Organic LED
PTT Push To Talk
RoIP Radio-over-IP
RX Reception
TX Transmit
UART Universal Asynchronous Receiver/Transmitter
USB Universal Serial Bus
V Volt
Otros manuales para Swift A200
2
Tabla de contenidos
Otros manuales de Puerta de TRBOnet
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario














