www.transmittersolutionssmart.com Installation & User Manual

2
27
Technical Specification
Power Supply 230 VAC
Current consumption 30mA
Fuse Rating 230VAC 315mA T
Moisture Resistance Indoor Use Only
Dimensions W. 260mm D. 262mm H. 55mm
Technical Specs - Wi-Enterprise Controller
Power Supply 12 DC
Current consumption 110mA
Current consumption with load (max) 145mA
Relay Contact Rating 5 Amps /230V ac
Operating Temperature - 20 C to +60 C
Moisture Resistance IP 67 ( IP65 on Wi-Bio )
Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm
- Surface Mount W. 87mm D. 35mm H. 119mm
Technical Specs - Wi-
Enterprise
Door Controls
Features
Doors controlled
Users
User Groups
Time Zones
Door Groups
Reporting Facility
Challenge Facility
Logging
Input/Output Mapping
Supports Wireless & RS485 Networks
Automatic Backup Facility
Database Encryption
20
20000
128
128
128
Yes
Yes
Unlimited
CCTV & Lift control
Yes
Yes
Yes
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Ctrl Door No. Door Type Door Location Name Walk Test
2
3
Installation Records

3
26 Installation Record
Installation Steps
Step Description Page
1 Install the Controller using the Installation Diagrams 4-5
2 Wire the Controller using the Wiring Diagrams 8
3 Install and wire each Door Control. Refer to the Door Control
Manual for instructions.
4 Connect the Controller to the PC using Network Diagrams 9-11
5 Restoring Factory Defaults 11
6 Setting up TCP-IP 12
7 Phase 1- Setting up the Controller via the PC application 14
8 Phase 2 - Configuring the Controller via the PC application 15
9 Phase 3 - Defaulting Door Controls 16
10 Phase 4 - Enrolling Door Controls 16-18
11 Phase 5 - Configuring Users 19
12 Phase 6 - Configuring Access Levels 20
13 Phase 7 - Downloading Configuration 20
14 Enrolling User Fingerprints 21
15 Correct Finger Placement techniques 22-25
Installation Steps
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
Ctrl Door No. Door Type Door Location Name Walk Test
1
2

Control Panel opening
remove screw cap remove retaining
screw
to remove cover pull
out on right and slide left
to remove cover pull
out on right and slide left
to remove cover
pull forward on
right and slide left
4 Installation Diagrams
Incorrect Finger Placement
25
Finger Placement Wi-BIO

Control Panel features
mount with 4 x 1.5 inch
No. 8 Security Type screws
rear tamper
switch
cable
entry
cable
entry
cable
entry
cable
entry
spare cap
access to rear
void for wiring
spirit level
mains pcb
mount holemount hole
mount hole
5
Installation Diagrams
Correct Finger Placement
24 Finger Placement Wi-BIO

6 System Overview
RS485 Connection to Door Controls
Door Control
#1
Door Control
#2
Door Control
#3
Door Control
#4 - 20
RS485 Network to Door Controls
Max Cable Length 1.4 km.
Daisy Chain Configuration Only.
Controller
#1
Controller
#2 - 3
Note: If using a single Controller,
an RS232 cable may be used.
Max cable length 10 meters
Place a 120ohm
Termination Resistor
across A & B on the last
Door Control in the chain.
Place a 120ohm
Termination Resistor
across A & B on the
Controller
TCP-IP connection to Controllers
or
RS485 Network to Controllers
Max number of Controllers 3
Max Cable Length 1.4 km
Incorrect Finger Placement
23
Finger Placement Wi-BIO
Poor Quality Image
Note: Poor Quality image, No Fingerprint
core on sensor window.
This can result in poor template quality that
can lead to false rejection issues later when
the user is trying to gain access.
Note: Incorrect placement : finger does not
fully cover the sensor window.

Wireless Connection to Door Controls
Door Control
#1
Door Control
#2
Door Control
#3
Door Control
#5 - 20
TCP-IP connection to Controllers
or
RS485 Network to Controllers
Max number of Controllers 3
Max Cable Length 1.4 km
Controller
#1
Controller
#2 - 3
Door Control
#4
Note: Door Controls can be installed within 30 meters
of the Controller or within 30 meters of any other Door Control
as each Door Control will function as a repeater. Each Door Control
transmits data to/from the Controller. These distances are a guideline.
The actual communication range depends on building shape and
construction methods used.
7
System Overview
Note: If using a single Controller,
an RS232 cable may be used.
Max cable length 10 meters
Correct Finger Placement
22 Finger Placement Wi-BIO
Note: Good Quality image, Fingerprint core
is center of sensor window
Note: Ensure that the core of finger is
centered on the sensor window during
the enrollment process. This will increase
the quality of the fingerprint template.
Ensure a value of at least 90% is achieved.
Good Quality Image
Note: The System does not store the finger
print. It uses an algorithm to generate a
binary representation using sample points
from the fingerprint. It uses this information
to then validate each users fingerprint.

Note : Used ONLY for
Wired 485 Network
Connections.
A
B
COM
TX
RX
PC Network
PC Direct
PC Network Connections
can be used for multiple
controllers See page
10 for wiring
Wiring Diagrams
8 Wiring Diagrams
Door Network
A
B
COM
1 2 3 4
OFF
ON
TCP_IP
3V Lithium
Inputs/outputs
IP1
IP2
0V
IP3
IP4
12V
OP1
OP2
OP3
OP4
0V
VOUT
DAT
CLK
SEN
Inputs/outputs
Cable Tie
Fuse Rating : 230VAC 315mA
Warning : Installation should only be carried out
by a suitably qualified person only.
Cable Tie
retaining
clips
Main Input Cable
230VAC
Neutral
Earth
Live
Remove Battery Tab
Pull
21
Operation Instructions
Enrolling User FingerPrints
Step Description
Note: Make sure the USB Fingerprint reader is attached to the PC
1. On the Users Tab , Select a User for fingerprint enrolment
2. Click on the ‘Fingerprints’ button.
3. Click on ‘+’ button to begin and place finger on the enrolment reader. An
image of the fingerprint will appear on the screen. Ensure that the image
quality is good and a value of at least 90% is achieved. Refer to section
‘Finger Placement’ for correct finger placement and example of good
quality image. Repeat this process if this is not achieved on first attempt.
Two fingerprint templates can be saved for each user.
4. Click ‘Save’ using a good quality template only. Poor Quality templates can
lead to false rejections later when trying to gain access

9
Network Diagrams for Single Controller
A
B
0V
TX
RX
A
B
0V
Door Network
PC Network
Connect DB9 cable
to serial port on PC
Maximum cable
length 10 meters
Direct Connect - All Dip Switches OFF
PC Direct
DB9 Female
Serial Cable
PC Direct Connection can be used, when
using ONLY one GSD Controller.
Set the Direct address to
ALL dip switches OFF
(see below )
Network Diagrams
OFF
ON
1 2 3 4
1
5
2
3
4
9
8
7
6
See page 11 on “Configuring Controller Communication” to setup the application
for serial communications
20 Operation Instructions
Phase 7 - Downloading Configuration
Phase 6 - Configuring Access Levels
Step Description
Access Levels are controlled by creating UserGroups and assigning the
UserGroup to a User as described in section ‘Configuring Users’.
1. UserGroups are created by combining pairs of DoorGroups with
Timezones. Each UserGroup can have up to 6 pairs of DoorGroups and
Timezones. Select DoorGroups and Timezones from the drop-down menus
to add to the current UserGroup.
2. Timezones are the periods of time for each day of the week that access
will be granted. Select times and tick the days of the week this time is valid.
4 time periods can be created for each timezone. Select ‘Holiday Access’
to grant access for holiday periods. Double click on the ‘Holiday Access’ to
add days to the holiday periods. Use the calendar to select these days.
3. DoorGroups are created by grouping doors together. e.g. all the entry and
exit doors could be grouped together as ‘Peremiter Doors’. Select a Door
from the ‘All Available Doors’ window and drag it to the ‘Doors in Current
Group’ to add it to the Door Group. Repeat for adding doors as desired.
Step Description
After all users, access levels and door control settings have been finalised,
a full download to the controller should be carried out.
1. Go to the ‘Settings’ tab and click on ‘Download Configuration’. A pop-up
window will appear, tracking the status of the download. All settings will be
downloaded to the Controller and Door Controls.

10 Network Diagrams
Network Diagrams for Multiple Controllers
19200 9600
12V - 1
0V - 2
B - 3
A - 4
A
B
0V
TX
RX
PC Direct
12V
PC Network
Connect using RS232-RS485
cable to serial port on PC
PC Network Connections, when using more
than one GSD Controller.
Daisy chain the PC network A , B , 0V to each controller.
Set an individual address for each controller
between 1 & 3 using the dip switches
(see below )
RS485 Converter
A
B
0V
TX
RX
PC Direct
Controller 1
Controller 2
PC Network
Address 1 - Set SW1 ON Address 2 - Set SW2 ON Address 3 - Set SW3 ON
Controller 1 Controller 2
Set Baud Rate to 19200 Daisy Chain
each controller
A
B
0V
1 2 3 4
Controller 3
OFF
ON
1 2 3 4
OFF
ON
1 2 3 4
OFF
ON
Phase 5 - Configuring Users
Step Description
1. Enable a User by ticking the ‘Enabled’ box for each User
2. Assign a Name to the User
3. Assign a UserGroup from the drop-down menu. The UserGroup will
determine the access levels for this User. Refer to section on page 20
‘Configuring Access Levels’ for information on User Groups.
4. Assign a Card , PIN number and enroll FingerPrints for the User. Refer to
section FingerPrint Enrolment on page 21
Click ‘save’ to transmit these changes to the Controller.
19
Operation Instructions
Tabla de contenidos
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario