3.2 T23 Track Ports
T23 Track has a different casing. It has no External GPS antenna and microphone ports. See image
belo .
Figure 5 - T23 Track ports
3.3 Configuring I/O ports
Inputs and outputs can be configured by INPUT and OUTPUT commands.
For Advanced use only!
INPUT default settings:
•INPUT,1,IGNITION,IGNITION,1,500,BOTH
•INPUT,2,SOS,SOS,0,2000,ON (1)
•INPUT,3,SENSOR,SENSOR,1,500,ON
•INPUT,4,GENERAL,INPUT,1,500,ON
OUTPUT default settings:
•OUTPUT,1,IMMOBILIZER,DISABLE,1,0
•OUTPUT,2,GENERAL,OUTPUT2,1,0 (2)
•OUTPUT,3,GENERAL,OUTPUT3,1,0 (3)
(1) T23: This is the correct SOS default setting hen T23-ATB is used ith Tramigo Intelligent Immobilizer
T23 Series: When T23-ATB used as a separate accessory; INPUT,2,SOS,SOS,1,2000,ON
(2) T23 Fleet and T23 Track: Output 2 is giving a ground all the time, until set ON and ground is lost.
(3) T23 Fleet and T23 Track: Not available, only ith T23.
INPUT DEFINITION OUTPUT
(1 - 4) corresponds to PINS 5 -8 ID (1 - 3): Output number PINS 9 - 11)
(1 - 4): 1 = Ignition, 2 = SOS,
3 = General, 4 = General TYPE (1 - 2): 1 = Immobilizer, 2 = General
Defines the name of the command for
turning on/off the reporting. LITERAL (TEXT) Defines the name of the command for
turning on/off the reporting.
(1/0): Defines if 0 or 1 used for ON. HIGH (1/0): Defines if 0 or 1 used for ON
(0 - 9999): Wait (ms) before registering
input event (to filter noise). DELAY N/A
(ON/OFF/BOTH): When reports are sent REPORT WHEN N/A
N/A TIME
output signal is sent, 0 = continuous
Important Note!
T23: All inputs use 3V minimum and 2 V maximum for unit to detect "ON" state.
T23 Fleet and T23 Track: Inputs 1 and 3 use 3V minimum and 2 V maximum for unit to detect
"ON" state. Inputs 2 and 4 use GROUND to detect “ON” state.
T23 Fleet: Analog input and 1-Wire interface; refer to separate professional T23 Fleet accessory
installation guide.