OPERATION
The boiler is fired up in MANUALMODE. To start MANUALMODE press MENU and next use and .
When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can
be used during this operation with its whole range of power.
If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press MENU and
next -START. Operation status changes from STOP to FIRING UP.The blower is working with its maximum
power and the feeder delivers coal regularly.
o
When the BURNING OUT TEMPERATURE (35 C what is set by producer) is exceeded controller starts
HEATING.
If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder
operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as
the temperature is drawing away.
When the preset temperature is exceeded, the controller changes to HOLD mode. The feeder and blower begin
periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as
solid fuel.
If the boiler temperature decreases, controller changes over to HEATING. If the boiler temperature drops below
the value of BURNING OUT TEMPERATURE controller changes to STOP status. However controller cannot
change to STOP, if the FIRING UP time has not been completed since pressing START, that is setting of 1 hour
- made by producer.
The controller operation can be stopped at any time by pressing -STOP. In STOP status the blower
and feeder are stopped.
The CH pump and TW feeding pump control is accordingly relative to the temperatures of boiler and TW container
in each operation mode.
RESETING
The flickery arrows !, @, $, #and )inform which button must be used to operate MENU and make any
resetting.
and are for parameter changing
and are for MENU navigation
The BOILER TEMPERATURE resetting is being made on the main display.
The other settings can be changed after pressing MENU.
Displays after pressing MENU
!a@ WARM WATER
TEMP: 45)*
!b@ SEASON
WINTER)
!c@ MANUAL
$START$
a) TW(tap water) container temperature
b) the season edition
WINTER - central heating and tap water pumps control
SUMMER - tap water pump control only
c) MANUAL MODE ON
Pressing MENU while any parameter is being edited, returns
to the MAIN DISPLAY. If the operator makes any
modifications the controller will ask if those modifications are
to be entered to memory. If there is no reaction during 1 minute,
controller returns to MAIN DISPLAY and does not introduce
any new data.