TIS VENERA Series Manual de usuario

This product is a wall switch with touch buttons
designed for lights and scene control. It offers
customizable backlit color and covers for an easy
combination with interior schemes.
PRODUCT INFORMATION
Model: VEN-3S-3R-HC, VEN-2S-2R-HC
PRODUCT SPECIFICATIONS
Power Supply
Input voltage 110-230 VAC 50/60 Hz
Output power 3W / 12V
Protection Internal protection fuse
Current consumption 10-30 mA / 12 V DC
Output
Number of channels 2 / 3 (refer to model number)
Nominal voltage 110 / 230 V AC 50/60 Hz
Nominal current per channel
8 A / 230 VAC
Output switching current
Max switching current 10A/230 VAC resistive
6A/230 VAC florescent
Output service life 8A/230 VAC
Output switching times 277VAC / 30VDC
Output service life Mechanical endurance > 10,000,000 OPS
Output switching times
Operating time 8mS (at nomi. Volt)
Releasing time 5 mS (at nomi. Volt)
Max. operating frequency 25 cycle/min
TIS AIR WIFI signal 2.4 GHz
Protocol standard 802.11 b/g/n
Operation
touch buttons 4 touch Capacitive buttons for control …
Infrared receiver
Control it by TIS remote control
Backlight
RGB backlight indicators
TIS AIR
TIS protocol messages and commands
Upgrading
By WIFI Connection
Dimensions Length × Width × Height 85mm × 42mm × 109mm
Housing
Materials Fireproof PC/ Glass in front
Internal parts color Black or White
IP rating IP 50
TIS VENERA SERIES
2/3 Gang Touch Switch
INSTALLATION MANUAL

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
2
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
Mounting Location
Install in a dry, indoor area with a suitable
temperature and humidity range.
Electrical Wires
The recommended wire size for light
channels is 2.5mm, for the Line, Neutral,
and Load cables. The installer should
consider the total current consumption
when selecting the wires.
Warranty
There is a two-year warranty provided
by law. The hologram warranty seal and
product serial number are available on
each device.
Read Instructions
We recommend that you read this
Instruction Manual before installation.
Safety instructions
Electrical equipment should only be
installed and tted by electrically skilled
persons.
Failure to observe the instructions may
cause damage to the device and other
hazards.
These instructions are an integral part of
the product and must remain with the end
customer.
Programming
This device can be tested and programmed
manually. Advanced programming
requires knowledge of the TIS Device
Search software and instruction in the TIS
advanced training courses.
Simple Installation
You can use 2 screws to install this panel
on wall; it ts on most junction box sizes.

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
3
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
INSTALLATION STEPS
2Remove the switch cover. Unscrew and
pull the wall switch out. Take the wires
out of the load and line.
3There should be a total of 3-5 wires (3
wires if 1 gang, 4 wires if 2 gangs, 5 wires
if 3 gangs). Find the neutral wire.
1Turn off the power at the main circuit
breaker to turn off voltage supply to the
switch.
Neutral
Live
Switch 1
Switch 2
Earth
WARNING! HIGH VOLTAGE
Circuit Breaker
OFF

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
4
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
INSTALLATION STEPS
4Turn on the power at the main power
breaker, and carefully identify the live
wire using a voltage tester.
5Turn off the power at the main power
breaker again to turn off the voltage
supply to the switch.
6
▸
Attach the neutral wire to the N terminal.
▸
Attach the live wire to the L terminal.
▸
Attach the Switch 1 wire to the S1
terminal.
▸
Attach the Switch 2 wire to the S2
terminal.
▸
Attach the Switch 3 wire to the S3
terminal.
Circuit Breaker
ON
Circuit Breaker
OFF

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
5
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
INSTALLATION STEPS
7Insert the Venera panel and the wires in
the box, and secure the panel using 2
screws.
8
9
Install the Venera panel’s top cover as
shown in the picture.
Install the Venera power, and turn the
breaker on. The panel should turn on.
Circuit Breaker
ON

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
6
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
SERVER LINKING
In order for a project to be fully linked to the TIS server, server conguration must be enabled
in just 1 product within that project.
If you have already done that with any other panel, just ignore these steps and proceed to
conguration steps.
To do the server linking, complete the following steps:
2On the Venera panel, touch and hold
buttons 1 & 2 for 6 seconds. The buttons
will start blinking.
(To see the position of buttons 1 & 2 on
different models please refer to page 7.)
1In the TIS App, go to Settings Connect
Server, and follow the steps by entering
your SSID password.
21
6”

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
7
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
Button 1Button 1
Button 2
Button 2
Button 2Button 2
Button 1 Button 1
VEN-3S-3R-HC
VEN-4S-4R-HC
VEN-2S-2R-HC
VEN-6S-HC
POSITION OF BUTTONS 1 & 2

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
8
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
SERVER LINKING
4Select your server option and 4-digit
password. Then, press Save.
3On the TIS app, press Search and wait
for a few seconds. The panel will link to
your WiFi, and the buttons start blinking.
21

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
9
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
21
1In the TIS App, go to the settings and
select TIS Air cong and enter your SSID
password.
2On the Venera panel, touch and hold the
buttons 1 & 2 for 6 seconds; The buttons
will start blinking.
(To see the position of buttons 1 & 2 on
different models please refer to page 7.)
CONFIGURATION STEPS
3On the TIS app, press search and wait for
a few seconds, the panel will link to your
WiFi and the buttons will start blinking.
6”

INSTALLATION MANUAL
Model : VEN-3S-3R-HC, VEN-2S-2R-HC
TIS Venera SerIeS
10
www.tiscontrol.com
TIS CONTROL LIMITED
Wanchai, Hong Kong
TIS CONTROL PTY LIMITED
SA , AUSTRALIA
Copyright © 2022 TIS, All Rights Reserved
TIS Logo is registered trademark of TIS CONTROL.
All of the specification are subject to change without notice.
2
2
1
1
4 Select the room and then select channel
names and icons.
5 Go to the congured room’s page and
start controlling.
CONFIGURATION STEPS
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Cambiar de TIS