7
Installing the Load bars
1. Select a locaon that provides a solid, level and well drained surface.
2. Ensure the load bars and plaorm are well secured and clear of any obstrucons.
3. Ensure the plaorm does not rock or move and ll with spacers if required.
4. Either bolt the load bars to the concreate pad or locate them on studs set into the concrete.
It is important that the load bars and plaorm sit at without any rocking or twisng.
5. Connect the load bar cables to the T40indicator.
A beep will sound indicang a successful connecon of the load bars.
WARNING – DO NOT WELD THE LOADBARS OR ANY STRUCTURE THAT THEY ARE ATTACHED TO.
Load bars contain sensive electronic devices which will be damaged by welding.
Damaged caused from welding, will not be warranted.
Weighing
There are 2 ways to use the T40 scale. It can be used on its own, or in conjuncon with the Thunderbird
Data Management mobile applicaon. Use the applicaon if you wish to record your session when
weighing animals.
Before Weighing
1. Check the load bars are connected to the T40 Indicator
2. Turn on the T40 Indicator using the Power Buon.
3. Check the weight displayed is ZERO. If not, press the TARE buon.