Thoth Technology Argus 2000 Manual de usuario

Argus 2000 IR Spectrometer
Owner’s Manual
Document Number
OG274001
Issue
Release 1.03
© Thoth Technology, 2018. All rights reserved. This document is proprietary and should not be disseminated
without the written consent of Thoth Technology. The information contained in this document is restricted
and may be subject to international laws governing spacecraft products and services.
Thoth Technology Inc., Algonquin Radio Observatory, Achray Road, RR6
Pembroke, Ontario K8A 6W7, Canada

Page 2 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
Table of Contents
1PRODUCT KEY .................................................................................................... 5
2PURPOSE ............................................................................................................ 6
3SCOPE ................................................................................................................. 6
4SYMBOLS USED ................................................................................................. 6
5TRADEMARKS .................................................................................................... 6
6IMPORTANT SAFETY INSTRUCTIONS .............................................................. 7
7PACKAGE CONTENTS ....................................................................................... 7
8PRODUCT FEATURES ........................................................................................ 8
8.1Specifications ...........................................................................................................9
8.2Detector System ..................................................................................................... 10
8.3Optical Design ....................................................................................................... 13
8.4Optical Efficiency .................................................................................................. 13
8.5Angular Sensitivity ................................................................................................. 14
8.6Response to Collimated Monochromatic Laser Source ........................................ 15
8.7Functional Design.................................................................................................. 15
8.8Applications ........................................................................................................... 17
8.8.1Observing atmospheric gas and mineral species.................................................................17
9GROUND SYSTEM ELECTRONICS SETUP ..................................................... 22
10ARGUS GSE TEST APPLICATION ................................................................... 22
10.1Argus Status Message ............................................................................................23
10.2Adjusting Spectrum Pixel Range...........................................................................23
10.3Commanding the Instrument Settings ..................................................................23
10.4Data Logging .........................................................................................................24

Page 3 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
10.5Communications....................................................................................................24
11INTEGRATION ................................................................................................... 24
11.1Power Interface ......................................................................................................24
11.2Communications Interface ....................................................................................24
11.3Timing of Spectra Acquisition and Co-Adding Feature .......................................25
11.4Data Packet Format ...............................................................................................25
11.5Connectors .............................................................................................................28
11.6Mechanical Interfaces............................................................................................30
11.7Environment ..........................................................................................................32
12OPERATION ....................................................................................................... 33
12.1Command Format (Models 01-03).........................................................................33
12.1.2Command List .........................................................................................................................35
12.2Command Format (Model 04) ...............................................................................37
12.2.2Command List Model 04........................................................................................................40
13TROUBLESHOOTING ........................................................................................ 43
14WARRANTY ....................................................................................................... 43
14.1Disclaimer ..............................................................................................................44

Page 4 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
Release Notes
Issue Revisions Date
1.01
1.02
1.03
Draft for release.
Revised, corrected and enlarged
Revised
1 December 2017
16 March 2018
15 August 2018

Page 5 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
1 Product Key
The product code format for the Argus instruments described in this manual is:
ARGUS2000XYZ-NN.
The code descriptions are as follows:
Table 1: X Letter Code Key
Letter Code Description
A Aluminum optics
G Gold optics
S Space certified
N UAV grade
Table 2: Y Letter Code Key
Letter Code Description
U Unit only (kit excluded)
K Kit included
Table 3: Z Letter Code Key
Letter Code Description
L Standard range
E Extended range

Page 6 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
Table 4: NN Number Code Key
Number Code Description
01 700 nm – 1150 nm range
02 1000 nm –1650 nm range
03 1240 nm – 2000 nm extended range
04 1730 nm – 2200 nm extended range
2 Purpose
The purpose of this guide is to provide explanations and procedures for installing, operating,
maintaining and troubleshooting the Argus 2000 IR Spectrometer.
3 Scope
This document provides safety guidelines, setup information, operating instructions,
troubleshooting procedures and interface and technical specifications for the Argus 2000 IR
Spectrometer.
4 Symbols Used
The following symbols are used in this document.
CAUTION
Cautions identify conditions or practices that could result in damage to the
instrument or other equipment.
5 Trademarks
Argus is a registered trademark of Thoth Technology Inc.
!

Page 7 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
6 Important Safety Instructions
CAUTION
This guide contains important safety instructions that should be followed during
handling, installation and operation of this product. Be sure to read and understand
these safety instructions prior to handling.
Before installing or using this product, read all instructions and cautionary markings located
in this guide.
The instrument should be handled with gloves in a suitable clean room environment. Care
should be taken not to contact optical surfaces or instrument corners.
Do not attempt to open or unseal the unit. This product contains no serviceable parts.
The instrument shall be accommodated in a temperature and humidity controlled clean room
of cleanliness class no worse than 100,000 during handling, assembly, integration and test.
Anti-static grounding procedures must be observed when handling the instrument or
interface electronics. Care should be taken to align connector keys prior to insertion of
instrument interface.
Do not shock the instrument physically or expose this unit to liquids of any type.
7 Package Contents
The Argus instrument and GSE Kit includes the items shown in Figure 1 and itemized in
Table 5.
!

Page 8 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
Figure 1: Argus Instrument and GSE Kit.
Table 5: Argus GSE Kit Contents
Item Location (Figure 1) Description
1 Center Argus unit
2 Top left Shipping case
3 Top right Argus ground test display laptop
4 Bottom Left Argus power and communications interface
cable, example electrical and mechanical
mounting hardware.
5 Bottom Center Laptop serial interface USB adapter
6 Bottom Center Right Argus power USB adapter (5V)
7 Bottom Center Left Laptop power module
8 Bottom Right Laptop mains power cable (NEMA 5-15)
8 Product Features
The Argus spectrometer operates in the near infrared band in the standard range or in extended
range versions. For instrument spectral variations please see the product key. Argus features a
surface resolution of approximately 1.6 km when deployed in Low Earth Orbit (LEO). The
device uses a detector array of 1x256 elements that is actively cooled. Each pixel has a native
radiometric resolution of 10-bits. For models with numbers 01-03 resolution may be enhanced to

Page 9 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
13-bit performance by utilizing the integrations setting to co-add successive spectra. The device
includes a microcontroller, which controls the instrument’s components. The device operates
typically in a continuous single-pixel scanning mode with approximately 100 illuminated spectral
channels.
8.1 Specifications
The technical specifications for Argus 2000 are summarized in Table 6, below.

Page 10 of 44
Commercial In Confidence
© Thoth Technology, 2018. All rights reserved.
OG274001
Table 6: Technical Specifications, Argus 2000 Spectrometer
Argus 2000 Specification
1. Type Grating spectrometer
2. Configuration Single aperture spectrometer
3. Field of View 0.15º viewing angle around centered camera boresight with 15mm
fore-optics
4. Mass ~280 g
5. Accommodation 46 mm x 80 mm x 80 mm
6. Operating Temp. -20ºC to +40ºC operating temperature
7. Survival Temp. -25ºC to + 50ºC survival temperature
8. Detector InGaAs diode arrays with Peltier cooler
9. Grating 300 g/mm
10. Electronics microprocessor controlled 10-bit ADC (co-adding feature to enhance
precision to 13-bit, models 01-03), 3.6-4.2V input rail 250mA-1500mA
(375mA typical)
11. Operational Modes –Continuous cycle, constant integration time with co-adding feature
–Adaptive Exposure mode
12. Data Delivery Fixed length parity striped packets of single or co-added spectra with
sequence number, temperature, array temperature and operating
parameters
13. Interface Serial interface RS232 protocol
14. Spectral Channels 100 (typical)
15. Integration Time 500 μs to 4.096 sec
16. Handling Shipped by courier in ruggedized carrying case
8.2 Detector System
A linear gallium arsenide (InGaAs) photodiode array with high-quantum efficiency pixels in the
infrared detect radiation emitted for a 1.5 km2surface tile, assuming LEO orbit altitude of 600
km, that has been divided spectrally by the grating optics. The array is a hybrid InGaAs and
CMOS acitve-pixel readout electronics in which the photo-current is buffered, amplified and
stored. Channels are differentially sampled as a form of double correlated sampling. Two values
of feedback capacitor may be selected (the HIGH setting enhances dynamic range, the LOW
setting increases sensitivity). Typical device quantum efficiencies are shown in the figures below.
Tabla de contenidos
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK