Stage 1: How to install your thermostat
MAX LOAD 16A
ALL ELECTRICAL WORK MUST COMPLY WITH IEE 17TH EDITION
PART P REGULATIONS
! IMPORTANT SAFETY PRECAUTIONS !
Checklist
ADHESIVE AND/OR LEVELLING COMPOUND FULLY CURED
THERMOSTAT WIRED CORRECTLY TO AN RCD
THERMOSTAT POWERS UP
ENSURE ALL SUBSTRATES AND ADHESIVES ARE FULLY DRY
AND CURED BEFORE POWERING UP YOUR THERMOSTAT.
!
!
!
Stage 2: How to use your 5260 thermostat
Use the Temperature Dial on the front of the thermostat to set the
desired floor temperature.
Use the Power Switch on the front of the thermostat to switch the
system On & Off.
When the floor temperature is less then the set temperature and the
Power Switch is in the On position, the heating indicator LED will be
illuminated until the floor reaches the set temperature.
In normal use the thermostat is left On and will automatically maintain
the set floor temperature.
For holidays or night time economy, use the Temperature Dial to select a
lower, more economical temperature.
Operation: How to use your Thermostat
You can use the 5260 in conjunction with a Multizone Programmer
(5263) in large multizone underfloor heating systems.
See page 5 of the 5263 installation guide available from our website.
PRO TIP
5260 Face Plate Explanation Pre-set Temperature Adjustment Diagram
Pre-set Temperature: Adjustment
It is generally accepted that the maximum surface temperature of the
floor finish should be between 27oC - 29oC. The thermostat is fully
adjustable to meet the floor finish manufacturer guidelines.
At the rear of the thermostat Face Plate are two dial, one marked Max
and one marked Min. Using ta 3mm slotted screwdriver, adjust the
relevant dials to set a new Maximum or Minimum floor temperature.
Heating indicator
Temperature dial
Minimum dial
Power switch
Pilot wire indicator
Maximum dial