USDT 3002
© 06279 usdt_3002.monus.indd
| 8
3. Activating the Operating System
User has the option of a one or two relay system
1
3
2
backwards forward
SET
(Selection / Adjustment mode)
Operation cont-
rol lamp
Arr 1 Arr 2
1. AC power supply must be activated. The controller passes
an initialisation phase in which the operating control lamp
flashes red and green. At this point the controller is in au-
tomatic operation with factory settings.
Arr 1. Controller is ready for operation o the user may
activate the 2nd relay:
2. - Arr 2: Extended Solar System (with second relay)
-locate Arr by holding down forward key for 2 seconds
-press center key to begin set
-increase to Arr 2 using forward key
-press center key to save adjustment
Now the controller is ready for operation.
4. Controller parameter and indication channels
4.1 Channel-overview
Legend:
x
Corresponding channel is available.
x*
Corresponding channel is available if the appropriate option
is activated.
Corresponding channel is only available if the option heat
quantity measurement is activated (OWMZ).
MEDT
The channel antifreeze content (MED%) is only shown if a
medium other than water or Tyfocor LS / G-LS (MEDT
0 or 3) is used. The adjustment is only appropriate when
using other types of antifreeze.
Corresponding channel is only available if the option heat
quantity measurement is deactivated (OWMZ).
Please note:
S3 and S4 are only indicated if sensors are connected.
channel Arr specification page
1 2*
COL x x Temperature collector 1 9
TST x Temperature tank 1 9
TSTL x Temperature tank 1 below 9
TSTU x Temperature tank 1 above 9
S3 x Temperature sensor 3 9
TRF Temperature return sensor 9
S4 Temperature sensor 4 9
h P1 x Operating hours relay 1 9
h P2 x Operating hours relay 2 9
kWh Heat quantity kWh 10
MWh Heat quantity MWh 10
Arr 1-2 System 8
DT O x x Switch-on temperature difference 10
DT F x x Switch-off temperature difference 10
S MX x x Maximum temperature tank 1 10
EM x x emergency temperature collector 1 10
channel Arr specification page
1 2*
OCX x x Option collector cooling collector 1 11
CMX x* x* Maximum temperature collector 1 11
OCN x x Option minimum limitation collector1 11
CMN x* x* Minimun temperature collector 1 11
OCF x x Option antifreeze collector 1 11
CFR x* x* Antifreeze temperature collector 1 11
OREC x x Option reccoling 11
O TC x x Option tube collector 12
AH O x Switch-on temp. for thermostat 1 12
AH F x Switch-off temp. for thermostat 1 12
OHQM x x Option WMZ 12
FMAX Maximum flow 12
MEDT Antifreeze type 10
MED% MEDT MEDT Antifreeze content 10
HND1 x x Manual operation relay 1 12
HND2 x x Manual operation relay 2 12
LANG x x Language 12
UNIT x x Change over °FAH / °CEL 12
PROG XX.XX Program number
VERS X.XX Version number