Whether you're a contractor, architect, builder or homeowner,
creating the perfect indoor environment has always been a challenge.
Therma·Ray, the world's #1name in thermal comfort systems introduces
you to the ultimate solution, SmartRooms. Please take the time to read
this installation guide carefully before you begin. Remember, accurate
measurements are the key to success for a proper installation.
Standard Package Includes:
1) SmartRooms Controller
2) 6 screws (2 painted white)
3) Box ring
4) 240/120 volt power module with built in Ground Fault Circuit
Interrupter (GFCI)
5) Extended double gang electrical box (Canada only)
NOT INCLUDED
4 - Wire Nuts
COMFORT CONTROLLER
Line Voltage Installation Guide
FOR USE ON:
· Heating only 240/120 Double Pole Applications with Power
Module.
· All Therma-Ray Radiant Heating products that will be connected to
120 or 240 volt power source.
ELECTRIC RATING:
· 16A at 240/120 Vac
· 3840W at 240 Vac (Non-Inductive)
· 1920W at 120 Vac (Non-Inductive)
TEMPERATURE DIFFERENTIAL
· Adjustable Range
SENSORS: By the time you are ready to connect your controller, the sensors
(if applicable) should already have been installed. Review the installation
instructions for your particular Therma-Ray Radiant Heating System for more
information regarding the sensors.
INSTALLATION
WARNING
· This controller when used with the power module is a line
voltage (240/120) control. Do not install it unless you are
completely familiar with house wiring. If improperly
handled, there can be a risk of electric shock hazard which
may cause serious injury or death.
· The SmartRooms Comfort Controller is rated for normal full
load current on a dual residential 20A circuit breaker or fuse
block. Do not use on circuits protected by higher-rated
over-current protection devices. Some sustained fault
conditions can cause product failure.
·Do NOT connect to voltage different from device rating.
CAUTION
· Disconnect power supply before making wire connections to
prevent electrical shock or equipment damage.
· All wiring must comply with applicable codes and
ordinances.
· Maximum load for this thermostat MUST NOT EXCEED
specified rating otherwise potential fire hazard exists.
NOTE: The power module has it's own built in Ground Fault Circuit
Interrupter (GFCI). Therefore do not install a GFCI breaker on the
circuit as this will cause the Controller to trip therefore preventing
your heating system from operating.
Diagram 1