3
2. Snooze function (comfort function)
•active in position 1, 2, 4, 6, 10
The dimmer dims from the current dimming value up to the
minimum brightness within the set dimming time and swit-
ches off (activation via double click).
3. Dimming switch-on function
•applies for position 1, 2, 4, 6, 7, 8, 10
The dimmer switches on with minimum brightness and dims
until one releases the button again, or the maximum bright-
ness has been reached (activation by pressing the button for
longer, > 1 s).
4. Switch-on brightness
•applies for position 1, 2, 4, 6, 7, 8, 10
•Switch-on brightness can be set (presetting 100%) (acti-
vation by pressing the button, < 1 s)
Teach in switch-on brightness
Set the desired switch-on brightness via the button at input
A1/A2 in position 1 (or 2, 4, 6, 7, 8, 10 ).
Keep the button pressed (> 10 seconds) until the teach in
is conrmed by a change in the brightness. Afterwards it is
set to the saved switch-on brightness.
5. Minimum brightness
•applies for position 3, 5
Teach in the minimum brightness
The pre-set minimum brightness is set in such a manner that
most lamps still light up.
Move the rotary switch to 5 (to 3 for compact uorescent
lamps). The current minimum brightness is approached.
Press the button at Input A1/A2 and dim up or down until
the desired minimum brightness value is reached.
Let go of the button; the brightness value is taken over.
Set the rotary switch back to the desired function.
▻Reason: if a certain brightness value is exceeded, cer-
tain compact uorescent lamps / LEDs go out and no
longer ignite.
Carry out settings only with warm compact uorescent
lamps (e.g., switch on for approx. 5 minutes).
6. 2-push button function using diode module
with double switch or rocker switch
•input B1 = push button input
•with switch-on brightness
•with dimming switch-on function
•ON button: switch on /dim up
OFF button: switch off /dim down
Diodenmodul
L
B1
AUS
EIN
Diode module 9070367
ON
OFF
7. Staircase time switch function
Setting the time with potentiometer (1 s – 60 min)
•Switch-off pre-warning: after expiry of the set time rapid
dimming down to 50% of the switch-in value. After 10 s,
slow dimming down to minimum brightness within 30 s.
•Long time function 60 mins: activation by pressing the
button for longer (conrmed by change in brightness)
LPressing the button again during the expiry time restarts
the expiry time (resettable, cannot be prematurely swit-
ched off).
30 s
10 s
1 s– 60 min
p
u
Zeit
Helligkeit
Brightness
Time
8. Switch function (e.g., for presence and motion
detector)
•At Input B1: not dened as push button but as switch
•Use of the diode module possible, up to 3 light settings
can be selected
•ON switch: slow dimming up; time can be set at potenti-
ometer 2; setpoint value set with function 5
OFF switch: slow dimming down; time can be set at
potentiometer 2 to minimum brightness, afterwards
switch off
p
p
Zeit
Helligkeit
100 %
x %
min
B1
A1/A2
0 %
langer Tastendruck
Brightness
Time
Long button push
Switch Switch
•At button A1/A2
– with switch-on brightness (preset 100 %)
– with dimming switch-on function
– with wake-up and snooze function
6. Operation
Light is OFF (with button: input A1/A2)
1 x short button
press
< 1 s Switch-on brightness
The dimmer starts with the switch-on bright-
ness taught-in (ex-factory 100 %)
1 x long button
press
> 1 s Dimming switch-on function
The dimmer switches on with minimum
brightness and dims until one releases the
button again, or the maximum brightness has
been reached.
2 x short button
press
Wake-up function
The dimmer switches on with minimum
brightness, then it is dimmed up using the
set dimming time (potentiometer ) until the
taught-in switch-on brightness.