FUNCTIONS DESCRIPTION
MODES
TYPICAL INSTALLATION
INTERNAL PHOTOCELLS
CONNECT TO TERMINAL 4.
FLASHING LAMP
24 VAC / MAX 20 W
A MOTOR
OPENS FIRST.
B MOTOR
AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING, A START OR PEDESTRIAN COMMAND INVERTS THE GATE MOVEMENT.
• DURING OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
COMMUNITY PLUS AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING, A START OR PEDESTRIAN COMMAND INVERTS THE GATE MOVEMENT.
• DURING OPENING, A START OR PEDESTRIAN COMMAND IS IGNORED.
STEP-BY-STEP: THE GATE STAYS OPEN AT THE END OF THE OPENING PHASE.
• DURING CLOSING AND OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
STEP-BY-STEP PLUS AUTOMATIC CLOSURE: THE GATE AUTOMATICALLY CLOSES AFTER THE SET PAUSE TIME.
• DURING CLOSING AND OPENING, A START OR PEDESTRIAN COMMAND STOPS THE GATE MOVEMENT.
OBSTACLE SENSOR: IF THE CONTROL BOARD DETECTS AN OBSTACLE IT INVERTS THE GATE MOVEMENT OR ENDS THE WORKING PHASE. IT INVERTS
THE GATE MOVEMENT IF IT’S THE FIRST OBSTACLE DETECTION IN THE CURRENT WORKING CYCLE (OPENING/CLOSURE). OTHERWISE, IT ENDS THE
WORKING PHASE SO TO FIND THE FULLY OPEN/CLOSED GATE POSITION AND RESTORE THE STANDARD GATE FUNCTIONING.
ELECTRONIC LIMIT SWITCH/ OBSTACLE SENSOR SLOW DOWN: IF THE CONTROL BOARD DETECTS AN OBSTACLE DURING THE SLOW DOWN, IT ENDS
THE CURRENTWORKING PHASE AS AN ELECTRONIC LIMIT SWITCH WOULD DO.
INTERNAL PROPERTY
ANTENNA
WITH RADIO
CASE
EXTERNAL PHOTOCELLS
CONNECT TO TERMINAL 3.
ELECTRIC-LOCK
SLOW DOWN: THE GATE SLOWS DOWN FOR THE SET SLOW DOWN TIME AT THE END OF THE OPENING AND CLOSING PHASES. DURING THE SLOW
DOWN PHASE THE MOTORS WORKS AT THEIR MAX POWER.
PEDESTRIAN: ONLY GATE LEAF A IS INVOLVED IN THE OPENING PHASE. GATE LEAF B REMAINS CLOSED.
SOFT START: THE MOTORS POWER INCREASES GRADUALLY TILL IT REACHES ITS MAX VALUE.
TESTS: THE CORRECT FUNCTIONING OF MOTOR AND PHOTOCELLS ARE CHECKED BEFORE ANY GATE MOVEMENT. IF ONE OF THE TWO TESTS FAILS
THE GATE DOES NOT MOVE. THE LEDS ON THE BOARD INDICATES THE TYPE OF FAILURE. THE MOTORS TEST FAILS WHEN ONE OR BOTH MOTORS
ARE IN TERMAL PROTECTION OR THERE IS A CONNECTION ERROR. THE PHOTOCELLS TEST FAILS IF TRANSMITTER AND RECEIVER ARE NOT PROPERLY
ALIGNED, IF THERE ARE INSTALLATION ERRORS, OR IF THE PHOTOCELLS ARE DAMAGED.
DISABLE NOT WIRED N.C. INPUTS: DISABLE ALL THE NOT WIRED N.C. INPUTS. IF LATER, A N.C. INPUT IS WIRED, THE BOARD WILL AUTOMATICALLY
ENABLE IT.
SINGLE MOTOR MODE: USEFUL FOR SINGLE LEAF SWING GATES. ONLY MOTOR A WILL BE ACTIVATED. THE WORKING TIMES AND OBSTACLE
SENSOR WILL BE ENABLED ONLYFOR MOTOR A.
FAST CLOSURE: THE GATE STARTS THE CLOSING PHASE 3 SEC AFTER THE INTERNAL/EXTERNAL OR EXTERNAL/INTERNAL PHOTOCELLS HAVE BEEN
ACTIVATED. THIS FUNCTION WORKS ONLY ONCE PER WORKING CYCLE AND ONLY IF THE GATE HAS NOT BEEN STOPPED DURING OPENING OR
CLOSING.
OIL RECIRCULATION / COLD CLIMATE MODE: THE MOTOR IS ACTIVATED AT THE MINIMUM POWER FOR 1 MIN EVERY 10 MIN WHEN THE GATE IS
FULLY OPEN/CLOSED, IF MORE THAN 20 MIN LASTED FROM LAST GATE MOVEMENT.
ELECTRIC-LOCK.
1. CONNECT TO OUT2.
10 12
+ - E.LOCK
10 12
OUT2 OUT2
10 12
10
12
ELECTRIC-LOCK
+
-
ELECTRIC-LOCK: ENABLED DURING OPENING FOR 3 SEC.
• KICK BACK AT CLOSING: AT THE END OF EACH CLOSING PHASE MOTOR A PUSHES THE LEAF A FOR 1 SEC AT MAX POWER SO TO PROPERLY CLOSE
THE GATE.
• KICK BACK AT OPENING: THE FIRST TIME THE GATE OPENS, THE GATE CLOSES FOR 1 SEC WITH THE ELECTRIC-LOCK ENABLED. AFTER THAT, THE
ELECTRIC-LOCK IS ENABLED FOR 3 SEC DURING OPENING.
• KICK BACK AT CLOSING AND OPENING: ENABLED THE FUNCTIONS PREVIOUSLY DESCRIBED.
2. CONNECT BOARD TERMINAL BLOCK
PINS 10 AND 12 TO ELECTRIC-LOCK
TERMINAL BLOCK PINS 10 AND 12.
3. CONNECT ELECTRIC-LOCK MODULE
PINS + AND - TO ELECTRIC-LOCK PINS
+ AND -