INSTALLATION
AND SERVICE
MANUAL
Revised 4-15


1
ULTRA CLEAN
LUBRICATED COMPRESSOR
INSTALLATION AND SERVICE MANUAL
This manual is for the installation and service of Tech West’s Ultra Clean Lubricated Compressors.
CONTENTS
Installation
Location Requirements 3
Figure 1: Wire and Breaker Size 3
Installation Steps 4
Figure 2: Compressor Connections 5
Start Up 6
Maintenance 6
Figure 3: Checking and Changing the Oil 7
Figure 4: Replacing Oil Indicator Lens 7
Parts Breakdown 8-11
Dessicant Dryer Parts Breakdown 12
Coalescing Filter Parts Breakdown 13
Single Ultra Clean Lubricated Compressor Assembly 14
Dual Ultra Clean Lubricated Compressor Assembly 15
Triple Ultra Clean Lubricated Compressor Assembly 16
Compressor Wiring Diagram 17
TROUBLE SHOOTING
Single Compressor Trouble Shooting 18-19
Dual Compressor Trouble Shooting 20-21
Triple Compressor Trouble Shooting 22-23
Air Line Sizing Chart 24
Maintenance & Service / Notes Sheet 24-25

Maintenance & Service / Notes
2

ULTRA CLEAN LUBRICATED COMPRESSOR
INSTALLATION
1. ULTRA CLEAN LUBRICATED COMPRESSOR LOCATION REQUIREMENTS
The Ultra Clean Lubricated Compressor location should be level, accessible and well ventilated.
If the Ultra Clean Lubricated Compressor will be located in a confined space, provide adequate ventilation.
Electrical
(1) Line voltage must be within the limits of Figure 1 below. (Install a “buck-boost
transformer” if line voltage is not between these values.) Circuit breaker switches
must be 20 - 30 amp depending on model and voltage necessary.
(2) Local code may require you to provide one quick disconnect (safety switch) for the
compressor.
(3) See Figure 1 below for breaker size and line voltage.
CAUTION - Voltage must be 110/128 v or motor damage may occur.
CAUTION - Voltage must be 208/240 v or motor damage may occur.
3
Figure 1: Recommended Wire and Breaker Size
Single Head Compressors
Model Voltage Amperage Wire Size Recommended
(Gauge) Breaker Size
ACL2S2 230 7.2 12 20
ACL2S1 115 13.6 12 20
ACL4D2 230 14.4 12 20
ACL6T2 230 21.6 10 30
Dual Head Compressors
Triple Head Compressors

ULTRA CLEAN LUBRICATED COMPRESSOR
INSTALLATION
2
2. INSTALLATION STEPS
This dental Compressor should only be installed by qualified personnel. Should any questions arise
during the installation, call Tech West Technical Support between the hours of 7:00 a.m. to 4:00 p.m.
(Pacific Standard Time).
Place the compressor in a clean, dry, well ventilated area, on a solid, level surface. Consider sound
level and insulate as needed. Be sure that adequate ventilation is available as the compressor is air
cooled. Ambient temperature in the equipment room should be within the temperature range of 40
degrees Fahrenheit minimum to 100 degrees Fahrenheit maximum.
(a) Check the shipping carton for damage. This could detect damage to the unit which might
otherwise be overlooked. Remove cardboard shipping carton.
(b) Remove the Lubricated Compressor from its shipping skid. Inspect the unit for damage.
Lubricated Compressors are shipped bolted to a pallet. This pallet is intended for shipping
only and should be discarded.
(c) Remove installation kit attached to pallet. It should contain the following:
(4) Isolation Feet
(1) Alternate Air Hookup Hose
(1) Bottle of Tech West Compressor Oil per Motor
(1) 5’ Flexible Air Hose
(d) Install isolation feet on tank legs.
(e) Remove shipping tape from spring-hinged oil filler cap(s).
(f) Install flexible hose to outlet on the compressor shut-off valve.
(g) Move compressor into place and level the motor platform.
(h) Install flexible hose to office air supply line.
(i) Install flexible hose to alternate fresh air supply.
(j) Wiring instructions:
1 Have all electrical connections made by qualified personnel only. All connections
should be in accordance with local codes.
2 Use the chart on page 1 to help determine the proper line and breaker size for
the unit that is being installed.
4

5
ULTRA CLEAN LUBRICATED COMPRESSOR
INSTALLATION
2
3. CONNECTIONS
Electrical Connection
to disconnect and
electrical panel
220 v
(110 v / 220 v ) on the
single models only.
Air Out
Connection to building
supply line.
Alternate Air
Connection
to fresh air supply.
Figure 2
Dryer Purge
Connection

5. PERIODIC SERVICING
WEEKLY SERVICING
(a) Check the oil level. Refer to figure 2. Use only Tech West oil specially formulated for Tech
West Compressors.
DO NOT OVERFILL. Add oil only when the oil level remains below the center line of the oil-level
sight glass after the compressor has been idle for at least 5 minutes.
(b) Empty condensate drain bucket under the dryer.
MONTHLY SERVICING
(a) Crack the drain petcock on the bottom of the storage tank to check for water and drain if needed.
(b) Check pump-up times.
(c) Check the moisture indicator to see that it is still “blue”. If it is pink it is time to service the air dryer.
YEARLY SERVICING
(a) Repeat all of the monthly servicing.
(b) Change oil (part # CO-100).
(c) Replace the dessicant air dryer (part # RDC-100).
(d) Replace the ultra clean coalescing filter. (part # CFEO-375). This keeps drying system efficient.
(e) Replace alternate air filter (part # TIF-100). Reduces oil consumption and lengthens
compressor life and efficiency.
(f) Replace the moisture indicator on the compressor (part # MI-100).
6
ULTRA CLEAN LUBRICATED COMPRESSOR
INSTALLATION
4. START-UP STEPS
(a) Make sure the shut-off valve from the compressor tank is closed.
(b) Turn the breaker from the panel to the “ON” position.
(c) Turn power “ON” from the toggle switch on the compressor. Compressor should run quietly
and vibration free. The storage tank should start to build pressure.
(d) The compressor will run until the pressure gauge reads 100 psi. The compressor then will
automatically shut off and the dryer will purge with a quick blast of air.
(e) Using soapy water, check the compressor plumbing hook ups for leaks. Repair leaks if needed.
(f) Pressure test the entire plumbing system for leaks. Use the storage tank pressure gauge to
monitor a pressure drop. After the plumbing system has been pressurized for 30 minutes,
re-check the gauge for pressure drop. If there is a drop in pressure, find and repair all leaks
in the office plumbing.
AIR LEAKS ARE THE MAIN CAUSE OF COMPRESSOR FAILURES.
(g) Complete and mail in the warranty card for the compressor within ten days of installation.

7
Figure 3: Checking and Changing the Oil
D
O
N
O
T
O
V
E
R
F
I
L
L
K
E
E
P
F
U
L
L
Oil Filler Spout
Indicator Lens
Oil Drain Plug
Keep full to here.
Alternate
Drain Spout
Instructions
Add oil to compressor through
oil filler spout. Do not overfill.
Keep filled to level as shown
below. Oil should be changed
annually or when oil becomes
discolored.
Check oil level with compressor
off and compressor sitting level.
Figure 4: Replace Oil Indicator Lens
Important!
Drain oil from compressor head
before removing lens.
Indicator Lens
Retaining Ring Gasket
Note:
Replace only if damaged
or discolored.
part #OSG-100

8
6
5
3
KEY PART NO. DESCRIPTION UNIT
1 CCH-115 115 V COPELAND COMPRESSOR HEAD 1HP 1
2 CCH-230 230 V COPELAND COMPRESSOR HEAD 1 HP 1
3 CF-115 115 V COOLING FAN 1
4 CF-230 230 V COOLING FAN 1
5 CFS-100 COMPRESSOR FAN SHROUD 1
6 CFG-100 FINGER GUARD 1
7 OSG-100 OIL SIGHT GLASS 1
HEAD COVER AND FAN ASSEMBLY
4
12
7
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Compresor de aire de Tech West