TBB Energier Apollo CH2.0M Manual de usuario

Energier Apollo all in one inverter
User Manual
CH2.0M 24V 2000W 40A MPPT 100V 60A
CH2.0S 48V 2000W 20A MPPT 150V 60A
CH3.0S 48V 3000W 30A MPPT 150V 60A
CH4.0S 48V 4000W 40A MPPT 150V 60A
TBB POWER Co.,Ltd.
A1.1
www.tbbpower.com


Energier Apollo User Manual
Disclaimer
About this Manual
Unless specially agreed in writing, TBB POWER Co., Ltd.
Takes no warranty as to the accuracy, sufficiency of suitability of any technical or other information
provided in this manual or other documentation.
Assumes no responsibility or liability for loss or damage, whether direct, indirect, consequential
or incidental, which might arise out of the use of such information.
TBB offers standard warranty with its products, taking no responsibility for direct or indirect loss
due to equipment failure.
This manual describes TBB Energier Apollo product features and provides procedure of installations.
This manual is for anyone intending to install, use and maintain TBB Energier Apollo equipment.
Suitable for mounting on concrete or other non-combustible surface only
Caution : the DC and AC breaker must have been turned off before servicing
Made in China
WARNING : FIRE HAZARD

Energier Apollo User Manual
1. Safety instructions……………………………………………………….
1.3 Installation………………………………………………………………….
1.4 Transport and storage……………………………………………………….
2. Description of main function……………………………………………...
2.1 General description………………………………………………………….
2.2 Powerful and reliable Inverter…………………………………………………
2.3 Smart battery charger………………………………………………………..
2.3.1 AC charger………………………………………………………………….
2.3.2 Solar charge controller……………………………………………………….
2.4 System level functions……………………………………………………….
2.5 Working principle……………………………………………………………
3. Structure………………………………………………………………….
3.1 Product drawing……………………………………………………………..
3.2 Wiring area description……………………………………………….………
3.2.1 Wiring area view……………………………………………………………..
3.2.2 Wiring area view after remove upper service panel………………………………
1.2 Precaution regarding battery operation………………………………………..
1.1 General…………………………………………………………… …… …
Index
1
1
3
4
4
5
6
7
7
8
10
10
13
13
13
14
14
15
4. Installation………………………………………………………………...
4.1 Pre-installation………………………………………………………………
4.1.1 Material list………………………………………………………………….
4.1.2 Location…………………………………………………………………….
4.1.3 General advice……………………………………………………………….
4.2 Fix Energier Apollo……………………………………………………………
4.3 Connection of Battery cables………………………………………………….
4.4 Connecting to earth…………………………………………………………..
4.5 Connection of AC cabling……………………………………………………..
4.6 Connection of PV cabling……………………………………………………..
4.7 Other Connections…………………………………………………………..
4.7.1 Auxiliary output contact………………………………………………………
4.7.2 Dry input……………………………………………………………………
4.7.3 Battery Temperature Sensor (BTS)……………………………………………
16
16
16
16
17
17
17
20
20
22
24
24
24
24
254.7.4 Battery Voltage Sensor (VS)…………………………………………………...

Energier Apollo User Manual
6.6.1 Rated AC voltage and frequency………………………………………………
6.4.3 Disable AC charger…………………………………………………………..
6.5 How to set battery charging curve……………………………………………..
43
44
6.6 How to set inverter parameters……………………………………………… 44
44
4.7.5 Kinergy-TBB data logging stick (optional)……………………………………...
5.2 Working mode………………………………………………………………
5.2.1 Power backup mode………………………………………………………....
5.2.2 Solar mode…………………………………………………………………
5.3 Display panel……………………………………………………………….
5.3.1 LED indicators……………………………………………………………....
5.3.2 Buttons………………………………………………..……………………
5.4 LED indicators……………………………………………………………....
5.4.1 Main interface………………………………………………………….……
5.4.2 Status………………………………………………………………………
5.4.3 System information…………………………………………………….……
5.4.4 System alarm……………………………………………………………….
5.4.5 System setting……………………………………………………………...
5.4.6 System control………………………………………………………….…..
5.4.7 Statistical information for PV production……………………………………….
5.4.8 Event logs…………………………………………………………………..
5.5 Performing
equalization
charging……………………………………………..
6.1 Buttons function information in setting………………………………………...
6.2 Default setting………………………………………...……………………..
6.3 Basic setting after installation…………………………………………………
6.3.1 Battery setting………………………………………………………………
6.3.2 Working mode setting………………………………………………………..
6.3.3 Date and time setting………………………………………………………...
6.4 How to set AC input parameters………………………………………………
6.4.1 AC source setting…………….……….……….……….……….……….…...
6.4.2 AC input current limit setting………………………………………………….
6. Configuration……………………………………………………………..
5.1 Main Switch (On/Off)…………………………………………………………
5. Operation…………………………………………………………………
26
27
27
27
27
27
28
28
29
29
30
30
31
31
31
31
32
32
33
35
35
36
39
39
39
42
43
43
43

Energier Apollo User Manual
6.6.2 Battery low voltage setting…………………………………………………...
6.8 How to get AGS function……………………………………………………..
6.9 How to restore factory setting………………………………………………...
6.10 Configurations by computer tool (Rapconfig)…………………………………...
7. Trouble shooting table……………………………………………………
8. Maintenance………………………………………………………………
9. Technical data…………………………………………..…………………
6.7 How to program trigger source of dry output contact……………………………
6.6.3 How to set power saving function……………………………………………..
45
45
46
46
46
47
48
50
52

Energier Apollo User Manual
Thanks for choosing TBB products and this manual is suitable for Energier Apollo. This chapter
contains important safety and operation instructions. Read and keep this User Manual well for later
reference.
The Energier Apollo needs to be installed by professionals and please pay attention to the following
points prior to installation:
1)
Please check the input voltage or battery voltage is same as the nominal input voltage of the
inverter.
2)
Please connect positive terminal “+” of battery to “+” input of the inverter.
3)
Please connect negative terminal “-” of battery to “-” input of the inverter.
4)
Please connect positive terminal “+” of photovoltaic panel to “PV+” input of the inverter.
5)
Please connect negative terminal “-” of photovoltaic panel to “PV-” input of the inverter.
6)
Please use the shortest cable to connect and ensure the secure connection.
7)
While connecting, please secure the connection and avoid short cut between positive terminal
and negative terminal of battery, which will cause damage to battery.
8)
Inverter will have high voltage inside. Only authorized electrician can open the case.
9)
The inverter is not designed to use in any life retaining equipment. There should be safe backup
measures to ensure that the failure of the power supply does not affect the continuous operation
of life first aid or maintenance devices.
1. Safety instructions
1.1 General
WARNING: ELECTRICAL SHOCK HAZARD
1
As dangerous voltages and high temperature exist within the Energier Apollo, only
qualified and authorized maintenance personnel are permitted to open and repair it.
There are dangerous voltage existed on the input or output terminals, even when
Energier Apollo has been switched off.

Energier Apollo User Manual
2
To avoid ELECTRICAL SHOCK HAZARD
Please make sure Energier Apollo has been turned off, and AC supply and DC supply
have been switched off before open and repair it.
Please make sure the battery bank protected by enclosure complied with safety
standards.
Where a Residual Current Device (RCD) or Residual Current Monitor (RCM) device is
used for protection in case of direct or indirect contact, only a RCD or RCM of Type B
is allowed on the supply side of this product.
This manual contains information concerning the installation and operation of the
Energier Apollo. All relevant parts of the manual should be read prior to commencing
the installation. Please follow the local stipulation meantime.
Any operations against safety requirement or against design, manufacture, safety
standard, are out of the manufacturer warranty.

Energier Apollo User Manual
3
1.2 Precaution regarding battery operation
Servicing of batteries should be performed or supervised by knowledgeable personnel about
batteries and the precaution requirements.
When replacing batteries, replace with the same type and number of batteries or battery packs.
General instructions regarding removal and installation of batteries.
CAUTION: Do not dispose of batteries in fire. The batteries may explode.
CAUTION: Do not open or damage batteries. Released electrolyte is harmful to skin and eyes.
It may be toxic.
CAUTION: A battery can present a risk of electrical shock and high short-circuit current. The
following precautions should be observed when working on batteries:
a) Remove watches, rings, or other metal objects.
b) Use tools with insulated handles.
c) Wear rubber gloves and boots.
d) Do not lay tools or metal parts on top of batteries.
e) Disconnect charging source prior to connecting or disconnecting battery terminals.
f) Determine if battery is inadvertently grounded. If inadvertently grounded, remove source
from ground. Contact with any part of a grounded battery can result in electrical shock. The
likelihood of such shock can be reduced if such grounds are removed during installation and
maintenance (applicable to equipment and remote battery supplies not having a grounded
supply circuit).
CAUTION: A battery can present a risk of electrical shock.
The battery may generate flammable gas during charging. NEVER smoke or allow a spark or flame
in vicinity of a battery.

Energier Apollo User Manual
4
1.3 Installation
Read the installation instructions in the manual before installing the equipment.
This is a Safety Class I product (supplied with a protective grounding terminal).
Uninterruptible protective grounding must be provided at the AC input and/or output
terminals. Alternatively the grounding point located externally on the product may be
used.
Whenever it is likely that the grounding protection has been damaged, the product must be
turned off and secured against unintended operation, please contact qualified service staff.
Ensure that the DC and AC input cables are fused and fitted with circuit breakers. Never replace a
safety component with a different type. Consult the manual to determine the correct component.
To avoid fire and electrical shock, make sure all cables selected with right gauge and being connected
well and tightly. Smaller diameter and broken cables are not allowed to use.
Warning: to avoid fire,make sure to keep Energier Apollo far from
inflammable and explosive substance
The product is designed for indoor use, ensure that the equipment is used under the correct ambient
conditions. Never operate the product in a wet or dusty environment. Ensure there is adequate free
space for ventilation around the product and check that ventilation vents are not blocked.
Ensure that the required system voltage does not exceed the rated value.
1.4 Transport and storage
Ensure that the mains power and battery cables have been disconnected before storing or
transporting the product.
No liability can be accepted for any transport damage if the equipment is shipped in non- original
packaging.
Store the product in a dry environment, the storage temperature must be between -40°C and 85°C.
Consult the battery manufacturer's manual in respect of transport, storage, charging, recharging
and disposal of the battery.
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Inversor de TBB