SUTO S217 OEM IO-Link Manual

English
Instruction and Operation Manual
S217 OEM IO-Link
Compact Dew Point Transmitter

Dear Customer,
Thank you for choosing our product.
The operating instructions must be read in full and carefully observed
before you start up the device. The manufacturer cannot be held liable
for any damage which occurs as a result of non-observance or non-
compliance with this manual.
Should the device be tampered with in any manner other than a
procedure which is described and specified in the manual, the warranty
is void and the manufacturer is e empt from liability.
The device is destined e clusively for the described application.
SUTO offers no guarantee for the suitability for any other purpose.
SUTO is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 S217 OEM IO-Link

Ta le of contents
1 Safety instructions.......................................................................4
2 Registered trademarks.................................................................6
3 Application..................................................................................6
4 Features.....................................................................................6
5 Technical data.............................................................................7
5.1 General................................................................................7
5.2 Accuracy ..............................................................................8
6 Dimensional drawing....................................................................8
7 Electrical connection ...................................................................9
8 IO-Link Interface ......................................................................10
8.1 TD.....................................................................................10
8.2 Communication....................................................................10
8.3 Features.............................................................................10
8.4 Process Data ......................................................................11
8.5 ariables..............................................................................11
8.6 Events................................................................................13
8.7 Error Types.........................................................................14
9 Installation ...............................................................................15
9.1 Installation requirements......................................................15
9.2 Installation procedure ..........................................................15
9.3 Order information................................................................19
10 Calibration..............................................................................19
11 Maintenance............................................................................19
12 Disposal or waste.....................................................................20
S217 OEM IO-Link 3

1 Safety instructions
1 Safety instructions
Please check if this instruction manual matches with the
product type.
Please observe all notes and instructions indicated in this
manual. It contains essential information which must be
observed before and during installation, operation and
maintenance. Therefore this instruction manual must be read carefully
by the technician as well as by the responsible user / qualified
personnel.
This instruction manual must be available at the operation site of the
dew point sensor at any time. In case of any obscurities or questions,
regarding this manual or the product, please contact the manufacturer.
WARNING!
Compressed air!
Any contact with quickly escaping air or ursting
parts of the compressed air system can lead to
serious injuries or even death!
•Do not e ceed the ma imum permitted pressure range (see
sensors label).
•Only use pressure tight installation material.
•Avoid that persons get hit escaping air or bursting parts of the
instrument.
•The system must be pressureless during maintenance work.
WARNING!
Voltage used for supply!
Any contact with energized parts of the product, may
lead to an electrical shock which can lead to serious
injuries or even death!
•Consider all regulations for electrical installations.
•The system must be disconnected from any power supply during
maintenance work.
•Any electrical work on the system is only allowed by authorized
qualified personal.
4 S217 OEM IO-Link

1 Safety instructions
ATTENTION!
Permitted operating parameters!
O serve the permitted operating parameters, any
operation exceeding this parameters can lead to
malfunctions and may lead to damage on the
instrument or the system.
•Do not e ceed the permitted operating parameters.
•Make sure the product is operated in its permitted limitations.
•Do not e ceed or undercut the permitted storage and operation
temperature and pressure.
General safety instructions
•It is not allowed to use the product in e plosive areas.
•Please observe the national regulations before/during installation
and operation.
Remarks
•It is not allowed to disassemble the product.
•Always use spanner to mount the product properly.
ATTENTION!
Measurement values can e affected y malfunction!
The product must e installed properly and
frequently maintained, otherwise it may lead to
wrong measurement values, which can lead to
wrong results.
Storage and transportation
•Make sure that the transportation temperature of the sensor is
between -30 ... +70°C.
•For transportation it is recommended to use the packaging which
comes with the sensor.
•Please make sure that the storage temperature of the sensor is
between -10 ... +50°C.
•Avoid direct UV and solar radiation during storage.
•For the storage the humidity must be <95% rH, no condensation.
S217 OEM IO-Link 5

2 Registered trademarks
2 Registered trademarks
SUTO® Registered trademark of SUTO iTEC
MODBUS® Registered trademark of the Modbus Organization,
Hopkinton, USA
HART®Registered trademark of the HART Communication
Foundation, Austin,USA
IO-Link®Registered Trademark of the PROFIBUS Nutzerorganisation
e.V., Germany
3 Application
The SUTO S217 OEM IO-Link Compact Dew Point Transmitter provides
reliable and long term stable dew point monitoring in industrial
applications. The newly developed device features improved signal and
stability in demanding industrial applications.
It’s designed for OEM applications in desiccant and refrigeration dryers.
The measured dew point is output via the IO-Link signal. The
parameters such as physical units, can be set e factory.
4 Features
•Small size makes it ideal for dryer installations
•Measures dew points down to –60ºC Td
•IO-Link communication interface
•IP65 casing provides robust protection in rough industrial
environment
•Very fast response time ensures safe and reliable indication
whenever dew points are out of valid ranges
•Can be installed directly into dryers through G 1/2” thread
•High accuracy of 1 … 2ºC Td dew point
•Withstands condensation
•M12 Connector
6 S217 OEM IO-Link

5 Technical data
5 Technical data
5.1 General
Measuring range
(model depending)
-60 ... +20°C Td
-20 ... +50°C Td
Accuracy ±1ºC Td [-5 … +50ºC]
±2ºC Td [-60 … -5ºC]
Pressure range -0.1 ... 5.0 MPa
-0.1 ... 35 MPa (optional)
Power supply 12 ... 30 VDC
Measured gas Non-corrosive gases
Ambient temperature -20 ... +50°C
Ambient humidity 0 ... 100% rH
Transport temperature -30 ... +70°C
Response time t90
(@ 4 l/min)
-40°C Td - > -20°C Td: 20 seconds
0°C Td - > -40°C Td: 120 seconds
Output signal IO-Link
IO-LINK Revision V1.1
Bitrate COM1
Minimum Cycle Time 40 ms
SIO Mode Supported No
Connection M12 connector, 5-pole (M12 plug included)
Casing Process connection: stain-less steel
Casing: Al alloy
Classification IP65
Process connection G ½” thread (ISO 228/1)
Sensor protection Stainless steel sinter filter pore size <30 µm
EMC According to IEC 61326-1
S217 OEM IO-Link 7

8 IO- ink Interface
8 IO-Link Interface
8.1 TD
Vendor ID 1490
Vendor Name SUTO iTEC
Vendor Te t www.suto-itec.com
Vendor URL www.suto-itec.com
Device ID 1038
8.2 Communication
IO-LINK Revision V1.1
Bitrate COM1
Minimum Cycle
Time
40 ms
SIO Mode
Supported
No
8.3 Features
Block
parametrization
Yes
Data storage Yes
10 S217 OEM IO-Link
Tabla de contenidos
Otros manuales de Transmisor de SUTO
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario