Stryker 1288010000 Manual de usuario

1288 HD Video Camera
User Guide
1288010000
1288010001
1288210105
1288710105


Contents
Warnings and Cautions ...................................... 3
Product Description and Intended Use .............. 6
Indications/Contraindications ......................................................7
The Camera Console ...................................................................8
The Camera Head ......................................................................10
The C-Mount Coupler ................................................................11
Setup and Interconnection .............................. 12
Setting Up the Console ..............................................................12
Setting Up the Camera Head .....................................................17
Setting Up the Coupler ..............................................................18
Operation ........................................................ 20
Powering the Camera On/Off ....................................................20
Using the Camera Head Buttons ...............................................20
Using the Touchscreen Interface ...............................................22
Controlling Remote Video Accessories .....................................26
Using the SFB Serial Interface ...................................................26
Using the DVI Fiber Outputs ......................................................26
Operating the Camera with a Light Source ......27
Troubleshooting............................................... 28
Cleaning, Reprocessing, and Maintenance ...... 31
Cleaning the Camera Console ...................................................31
Reprocessing the Camera Head ................................................31
Using Sterile Drapes ..................................................................38
Replacing the Fuses ..................................................................39
Periodic Maintenance Schedule ................................................39
Electromagnetic Compatibility ........................42
Warranty and Return Policy .............................46


3
Warnings and Cautions
Please read this manual and follow its instructions carefully. e words warning,
caution, and note carry special meaning and should be carefully reviewed:
Warning Indicates risks to the safety of the patient or user. Failure to
follow warnings may result in injury to the patient or user.
Caution Indicates risks to the equipment. Failure to follow cautions
may result in product damage.
Note: Provides special information to clarify instructions or present additional
useful information.
An exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
instructions in the manual.
A lightning bolt within a triangle is intended to warn of the
presence of hazardous voltage. Refer all service to authorized
personnel.
IMPORTANT SAFETY NOTICE: Before operating this device, please read
this operating manual thoroughly and carefully. When using this device
with a light source, re and/or severe injury may result to the patient, user,
or inanimate objects if the instructions in this manual are not followed.
All light sources can generate signicant amounts of heat at the scope tip,
the scope light post, the light cable tip, and/or near the light cable adapter.
Higher levels of brightness from the light source result in higher levels of
heat. Always adjust the brightness level of the camera and the monitor before
adjusting the brightness level of the light source. Adjust the brightness
level of the light source to the minimum brightness necessary to adequately
illuminate the surgical site. In addition, adjust the internal shutter of the
camera higher in order to run the light source at a lower intensity. Avoid
touching the scope tip or the light cable tip to the patient, and never place
them on top of the patient, as doing so may result in burns to the patient
or user. In addition, never place the scope tip, the scope light post, the light
cable adapter, or the light cable tip on the surgical drapes or other ammable
material, as doing so may result in re. Always place the light source in
standby mode whenever the scope is removed from the light cable or the
device is unattended. e scope tip, scope light post, light cable adapter,
and light cable tip will take several minutes to cool o aer being placed in
standby mode, and therefore may still result in re or burns to the patient,
user, or inanimate objects.

4
Warnings
To avoid potential serious injury to the user and the patient and/or damage to
this device, please note the following warnings:
1. Carefully unpack this unit and check if any damage occurred during
shipment. If damage is detected, refer to the Warranty and Return Policy
section of this manual.
2. Read this operating manual thoroughly, especially the warnings, and be
familiar with its contents before connecting and using this equipment.
3. Be a qualied physician, having complete knowledge of the use of this
equipment.
4. Test this equipment prior to a surgical procedure. is unit was fully tested
at the factory before shipment. Never use this equipment in the presence of
ammable or explosive gases.
5. Avoid dissembling any part of the camera head, as doing so may break the
seals, causing leakage and/or electric shock.
6. Avoid removing covers on the control unit, as doing so may cause damage to
electronics and/or electric shock.
7. Attempt no internal repairs or adjustments not specically detailed in this
operating manual.
8. Pay close attention to the care and cleaning instructions in this manual. Any
deviation may cause damage.
9. Never sterilize the camera console, because the delicate electronics cannot
withstand this procedure.
10. Disconnect the control unit from the electrical outlet when inspecting the
fuses.
11. Before each use, check the outer surface of the endoscope to ensure that
there are no rough surfaces, sharp edges, or protrusions.
12. Avoid dropping the camera system. e camera system contains sensitive
parts that are precisely aligned.
13. Ensure that readjustments, modications, and/or repairs are carried out by
persons authorized by Stryker Endoscopy.
14. Ensure that the electrical installation of the relevant operating room complies
with the NEC and CEC guidelines.
15. To avoid the risk of electric shock, this equipment must only be connected to
a supply mains with protective earth.
16. Multiple portable socket-outlets shall not be placed on the oor.
e warranty is void if any of these warnings are disregarded.

5
Symbol Definitions
In addition to the cautionary symbols already listed, other symbols found on
the 1288 HD Camera and in this manual have specic meanings that clarify the
proper use and storage of the 1288 HD Camera. e following list denes the
symbols associated with this product:
Operating humidity ratings
Operating pressure ratings
Operating temperature ratings
Denotes compliance to CAN/CSA C22.2 No601.1-M90
UL60601-1.
Type BF applied part
Equipotentiality
Protective Ground Earth
FireWire
Fuse rating
is symbol indicates that the waste of electrical and electronic
equipment must not be disposed as unsorted municipal waste
and must be collected separately. Please contact the manufacturer
or other authorized disposal company to decommission your
equipment.

6
Product Description and Intended Use
e Stryker Endoscopy 1288 HD Medical Video Camera is a high-denition
camera used to capture still and video images of endoscopic surgical applications.
e 1288 HD Medical Video Camera consists of three main components:
Component Stryker Part Number
Camera console 1288010000; 1288010001
Camera head 1288210105, 1288710105
C-mount coupler 1288020122
e 1288 HD also comes with various connection cables which, like the other
components, can be purchased together or separately.
Federal law (United States of America) restricts this device to use
by, or on the order of, a physician.

7
Indications/Contraindications
e 1288 HD Camera is indicated for use in general laparoscopy,
nasopharyngoscopy, ear endoscopy, sinuscopy, and plastic surgery wherevera
laparoscope/endoscope/arthroscope is indicated for use. A few examples of
the more common endoscopic surgeries are laparoscopic cholecystectomy,
laparoscopic hernia repair, laparoscopic appendectomy, laparoscopic pelvic
lymph node dissection, laparoscopically assisted hysterectomy, laparoscopic and
thorascopic anterior spinal fusion, anterior cruciate ligament reconstruction,
knee arthroscopy, shoulder arthroscopy, small joint arthroscopy, decompression
xation, wedge resection, lung biopsy, pleural biopsy, dorsal sympathectomy,
pleurodesis, internal mammary artery dissection for coronary artery bypass,
coronary artery bypass graing where endoscopic visualization is indicated
and examination of the evacuated cardiac chamber during performance of
valve replacement. e users of the camera are general surgeons, gynecologists,
cardiac surgeons, thoracic surgeons, plastic surgeons, orthopedic surgeons, ENT
surgeons and urologists.
ere are no known contraindications.

8
The Camera Console
e camera console or Camera Control Unit (CCU) is the control center for
the 1288 HD Medical Video Camera and processes the video and photographic
images captured during the surgical procedure. e console front panel features
a touch screen, where dierent menus can be accessed, including the controls
for adjusting the enhancement level, light level, zoom, and white balance, as
well as allows the selection of surgical specialty settings that optimize camera
performance for various, specic surgical procedures. e front panel also allows
activation of remote outputs. e rear panel provides ports for connecting the
1288 HD Camera to viewing and recording equipment, such as video monitors,
the SDC Ultra, or photo printers.
Front Panel
3
1 2
1. Power Switch Powers the camera ON and OFF
2. Touch Screen Allows navigation through dierent menus
for controlling the camera and adjusting the
system settings
3. Camera Connector Port Connects to the 1288 HD Camera Head
Otros manuales para 1288010000
1
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Videocámara de Stryker
Manuales populares de Videocámara de otras marcas

Panasonic
Panasonic AG-HMC152EN Manual de usuario

Insignia
Insignia NS-DCC5HB09 - Camcorder - 720p Manual de usuario

MYDLINK
MYDLINK DCS-6100LH Manual de usuario

Sony
Sony video Hi8 Handycam CCD-TR555 Manual de usuario

SECURECOM
SECURECOM V-5014B Manual de usuario

Panasonic
Panasonic HDC-SD100 Manual de usuario