Processor Control Board Replacement (Continued)
Page 7 of 16 Document # 1200445 Rev 11
08/10/2022
ACCESSING LOCATION VALUES
NOTE: Upon power up of the equipment, entry into all program locations is
provided for the first two minutes of operation. After this time, the
security lockout prevents changes from being made in any locations
above 15 (L015). To release the security lockout, refer to L099 or de-
energize the system and then energize again to reset the security free
function.
TO EDIT OR VIEW LOCATION SETTINGS:
1. Press and hold the M button until “EdIt” is shown on the control panel display.
2. Simultaneously press and hold the M and the up arrow buttons until “L000” shows on the control panel
display.
NOTE: If the M button is released before the “L000” is displayed, start over from Step 1.
3. Release the buttons. The display will flash between “L000” and the value in this location. The “L”
indicates "location" and the last three numbers indicate the specific location number.
4. Press the up arrow button until the location to be edited is reached. (e.g., Location 8 reads “L008”.)
5. After reaching the location to be edited, press and hold the M button. Use the up or the down arrow
buttons to modify the value to the desired setting.
6. Once all desired changes have been made, release the M button. Press the down arrow button until
“L000” is displayed. Then, press the down arrow button one more time and the normal display mode
will be shown. Any changes made to the location settings will automatically be saved.
NOTE: If no buttons on the control panel are pressed, after a brief amount of time, the control
panel display will automatically return to its normal operating mode and any changes made
to the location settings will automatically be saved.
CONFIGURATION MENU
Steffes heating systems have a Configuration Menu, which allows the systems to be customized to the power
company and consumer’s needs. This menu can be accessed on start-up and allows configuration settings to
be easily adjusted.
NOTE: Commercial systems (6100, 7100, 8100 and 9100 Series) do not generally use the configuration
menu since programming is site specific.
To access the Configuration Menu:
1. Energize the system. Access to the Configuration menu is allowed for the first two (2) minutes of
operation. If the system has been energized for over two minutes, power it off and back on.
2. Press and release the M button until the faceplate displays “CONF”.
3. Press the up arrow once and the faceplate will display “C000”. The display will flash between “C000”
and the corresponding value.
4. If necessary, edit the configuration by pressing and holding the Mbutton while using the up or the down
arrow button to change the value.
5. Once correct, release the buttons and press the up arrow to go to the next configuration (C001, etc.).
6. Repeat steps 4 through 5 until all configuration settings are adjusted to the desired values.
7. When configuration is complete, use the down arrow to leave the Configuration Menu.
In most applications only a few, if any, configuration changes will be necessary. Following is a description of
the configuration settings and their functions:
C000 Off-Peak Method of Charge Control - Sets method of brick core charge control used during off-peak
(charge) periods. Systems are configured for automatic charge control (5). For manual charge enter 6.