Status Pro T250 Manual de usuario

T250
Laser transmitter
Instruction manual
Another fine solution by

2
T250
Status Pro – T250 Instruction manual
CONTENTS
Instruction manual – English
Laser transmitter T250
(SP T250-P)
We woul like to congratulate you on the purchase of your Status Pro R310 Laser receiver.
Before initial usage you shoul carefully rea the safety instructions as well as the user
gui elines containe in this manual. We wish you every success when using this
Measurement Instrument.
Please note: User Manuals can be amen e when improvements or changes to the prouct
range have been carrie out. Use the link below to make sure you have the most up to
ate version of your User Manual. www.statuspro.co / achine_geo etry/docu ents/
Contents
1. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Class of laser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Stan ar s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Instrument care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6 Liability Exclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1 Aligning the laser beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Setting up the T250 for straightness measurements . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4. TECHNICAL DETAILS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6. PRODUCTS AND SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Status Pro – T250 Instruction manual 3
SAFETY INSTRUCTIONS
1. Safety Instructions
1.1 Class f Laser
The laser light emitte from a Status Pro Laser has an Output Rating of < 1,0 mW.
The Laser is place in the category „Class 2“ an is classifie as safe for the use as a
Measurement instrument. There are however a few safety aspects to be observe :
Cauti n!
•Do not stare into the laser beam.
•Do not point the laser beam at other people.
•Observe the local safety gui elines on Site an if in oubt consult
the Site safety Engineer.
•Do not use the equipmentin amp or moist locations.
•Ensure sha ing of the equipment against irect sunlight or heat
sources.
•Flui s or rain as well as extreme temperature con itions may
amage the equipment.
N te
Do not violently shake the Laser or other sensors an always
protect against falls. This can amage the structure or the optics
of the instrument resulting in false measurements.
Do not touch rotating parts when in use!

4
T250
Status Pro – T250 Instruction manual
SAFETY INSTRUCTIONS
1.2 Standards
All Status Pro Laser an Receiver Instruments are evelope an manufacture
accor ing to the following CE Stan ar s:
•EN 55 011
•EN 55 022
•EN 61 000-4-2
•EN 61 000-4-3
•EN 60 335
1.3 Instrument care
Your measurement instrument is esigne for use in an in ustrial environmentan can
withstan water splashes or light spray as well as ust. Clean the equipment using a soft
cotton cloth an a mil soap solution. Laser apertures as well as well as sensor areas
shoul only be cleane using a soft, ry an ust-free cloth. Do not use paper towels to
clean glass surfaces as they coul scratch. Avoi contact with grease, oil or oil-base
solutions when han ling the equipment..
1.4 Maintenance
The mechanical components of your equipment are prone to natural wear an tear! If the
Instrument appears to have a technical efect, contact the Manufacturer. Das Gerät nicht
eigenstän ig öffnen. Attempte repairs through unauthorise personnel makes the gua-
rantee null an voi !
Always store the equipment un er ry con itions an use the case for transportation.
N te
To be able to i entify the equipment when seeking a vice always
quote the serial number of the equipment. The Manufacturer oes
not accept any responsibility for amage incurre through incorrect
maintenance carrie out by non-authorise personnel.

Status Pro – T250 Instruction manual 5
SAFETY INSTRUCTIONS
1.5 Calibrati n
To guarantee measurement accuracy, an reliable operation of your
Status Pro Measure ment System, it is of utmost importance that the
recommen e Service Intervals be a here to. The System shoul be
checke for serviceability, an recalibrate by the Status Pro workshops
every 12 months.
Within the scope of the service checks, the complete system will also be examine for
possible wear or amage, as well as receiving any software up ates. The ate of the next
service check for your equipment is stampe on the Status Pro calibration sticker.
To ensure trouble-free processing of the service an calibration checks, simply use
the form you will fin using the following link:
www.statuspro.co / achine_geo etry/service_support/calibration_repair/
1.6 Liability Exclusi n
The Status Pro GmbH oes not accept responsibility for amage incurre through incor-
rect use or han ling of the equipment. To ensure correct usage, a foun e knowle ge of
the equipment is essential. It is of the utmost importance that you rea an un erstan the
Han book!
No responsibility will be accepte for amage incurre through ignorance or isregar ing
of the operating instructions.

6
T250
Status Pro – T250 Instruction manual
GETTING STARTED
2. Getting starte
The T250 Laser transmitter package (SP T250-P) comprises of the T250 Laser transmitter
(I - BG 830750), a mains power supply cable (III - BG800025), an an A apter (II - 832050)
enabling mounting of the T250 Laser when using a tripo , or when using the Borealign Kit
(SP BOREALIGN).
2.1 P wer supply
To operate the T250, connect the power
supply cable to the mains, an to the
socket on the T250 housing.
Ensure that the re markings on the plug
an the socket are correctly aligne .
This ensures correct polarity.
II: A apter
III: Power
supply cableI: Laser
transmitter T250

Status Pro – T250 Instruction manual 7
GETTING STARTED
2.2 Assembly
To use the T250 with a tripo , fasten the A apter (II) to the holes on the lower face of the
housing (V) using four of the screws elivere (IV). When elivere , the T250 will have
four screws on the front an the back facing.
The cylin rical face of the a apter has a 5/8“ threa for use with a tripo fitting.
To enable mounting on a vertical surface or for use with the Borealign kit, the A apter (II)
can be fitte to the front or the rear facing, again using the supplie screws. The 5/8”
threa is continuous, so the laser beam has sight through the A apter (II).
IV IV
II
II
V

8
T250
Status Pro – T250 Instruction manual
OPERATION
3
2
1
3. Operation
3.1 Aligning the laser
beam
There are four a justing screw assemblies
in the housing of the T250 enabling align -
ment of the laser beam. Each of these
assemblies comprises of a fine a justment
screw (1), a coarse a justment screw (2),
an a locking nut for the coarse a justment
screw (3).
To roughly a just the laser beam, loosen
the locking nut, align the laser beam with
the coarse screw (2) an the tighten up the
locking nut again. Fine a justment is
carrie out with locking nut tightene up.
When the T250 is in the horizontal position
(see below) the two screws on the upper
si e (Y1 & Y2) are use to align the laser
beam vertically.
The two screws on the si e (X1 & X2)
are use for the horizontal align ment of
the laser beam.
Y 1
X 1
X 2
Y 2
∆Y
∆X

Status Pro – T250 Instruction manual 9
OPERATION
Simply explaine , the laser beam of the T250 is house in a tube. Four screws are
attache to this tube, two on the si e an two on top. This arrangement enables alignment
of the laser angle as well as the parallel shift in both the vertical an the horizontal plane.
Example:
1) If the Y1 screw is move ownwar s
(screwe in) then the angle of the laser
beam will also slope ownwar s
2) If both Y1 an Y2 are move ownwar s
(screwe in) then the laser laser beam will
move parallelly ownwar s = parallel shift
The a justments in the horizontal plane
(X1 & X2) are carrie out in exactly the
same way.
X 1 X 2
Y 1
Y 1
Y 1 Y 2
Y 2

10
T250
Status Pro – T250 Instruction manual
OPERATION
3.2 Setting up the T250 f r straightness
measurements
A common task woul be to measure a Linear Gui e for straightness in the X an Y axes. To
be able to carry out this measurement, the laser beam has to be aligne , to make sure that
the laser beam hits the etector over the complete length of the gui e.
Aligning the T250 to carry out the measurement of a Linear gui e:
1) Mount the T250 on a tripo or irectly on the machine to be measure .
2) Connect the T250 to an appropriate power supply.
3) Position the sensor on the gui e as close as possible to the T250.
4) Carry out a rough a justment of the T250 Laser itself so the laser beam meets the centre
of the etector.
5) Move the etector as far away as possible from the T250 Laser.
6) A just the angle of the laser beam using the (X1 / Y1) screws until
the laser beam hits the centre of the sensor again.
7) Move the sensor as close to the laser as possible.
Tabla de contenidos
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario