-6-
Inst ll tion: Dip Switch Settings
Control He d Dip Switch Settings (cont’d)
Audio Pursuit, Visu l Pursuit, Progressive SS, nd TD Comp tibility
AUDIO PURSUIT ENABLE (DIP switch 5) and VISUAL PURSUIT ENABLE (DIP switch 6)
Normally slide switch position
acti ates “Pursuit Mode”:
a. The lights connected to all 3 slide switch positions will acti ate.
b. The siren will acti ate in Wail mode.
c. Your compatible traffic director (if connected to this unit) will acti ate in the
Warn mode.
To disable automatic acti ation of the siren (A DIO P RS IT) in position
, flip DIP
switch 5 up.
To disable automatic acti ation of the traffic director (VIS AL P RS IT) in position
,
flip DIP switch 6 up.
VISUAL PT ENABLE
AUDIO PT ENABLE
TD Auto-Acti ates in
Pursuit or Programmable
Traffic Director Does NOT
Auto-Acti ate in Pursuit
Siren Auto-Acti ates in
Pursuit or Programmable
Siren Does NOT
Auto-Acti ate in Pursuit
56
PROGRESSIVE ENABLE
Progressi e SS
Non-Progressi e SS
or Programmable SS
DISCRETE TD
Use 3 or 4 Output Signal for
TD w/Internal Controller
(Logic Controlled)
Use Built-In 8-Output
Siren TD Controller
8
PROGRESSIVE ENABLE (Progressive Slide Switch Ena le)
Normally the slide switch is “progressive”, meaning that each
position will add another function while keeping the pre ious
one(s) on. Position
1
11
1
acti ates the first function. Position
2
22
2
acti ates the functions connected to both
1
11
1
and
2
22
2
. Position
will acti ate all of the functions connected to
1
11
1
,
2
22
2
, and
3
33
3
.
To disable this feature so that each slide switch position is
independent from the others, flip DIP switch 7 up.
DISCRETE TD (Traffic Director Compati ility: 8-Output or 4-Output Logic)
TD Mode DIP switch (switch #3) must e ON (see page 5)!!
The default settings of this unit allow for operation
of our standard 8-head traffic directors (i.e. TD77,
TD92, TD93) through an internal controller within the
LCS850MG using 10 outputs from the 12-terminal
connector.
If the traffic director you will be using has a built-in
controller and only needs three or four “signal” wires to
operate, then flip DIP switch 8 up.
With this switch up, the default setting will be for
operation of our DL15-30W. To program the LCS850MG
to operate other traffic directors, please refer to page 32
of the Detailed Programming section.