5. Installation
5.1. General
This section describes the installation and infrastructure requirements for the
MFTX100. Departure from the instructions contained herein may void any
warranty provided by SRK.
The MFTX100 has been designed to be mounted in a standard 19” rack frame,
where it will occupy 3 rack units.
However, the transmitter may also be used in a free standing situation, so long
as all other requirements are met as below.
5.2. Environmental
The transmitter is intended for indoor use. The transmitter should be protected
from rainfall and direct sunlight, extremes of temperature and humidity and from
conditions of high dust levels. The transmitter shall not be operated at altitudes
in excess of 4000m above sea level. The transmitter must be installed on a flat,
stable surface. The transmitter must be installed in the upright position. The
transmitter must be installed in a location free from vermin and the ingress of
other animals. The transmitter shall not be installed in locations prone to
flooding. All ventilation orifices must be clear to allow adequate air flow.
If installed in a rack, the equipment immediately above the transmitter should not
overhang the fins of the heatsink on the rear of the transmitter.
5.3. Electrical supply
The electrical supply to the transmitter must be of the voltage, form and
frequency described in the specifications. All electrical wiring must be carried out
in accordance with local laws, standards and regulations. If power supply
voltages regularly fall outside specifications then a voltage regulator must be
installed between the supply inlet and the transmitter.