Sper scientific 850071 Manual de usuario

Environmental Quality
SD Card Logger
850071
Instruction Manual

2 3
TABLE OF CONTENTS
Materials Supplied . . . . . . . . . . . . . . . . . . . 6
Power Supply . . . . . . . . . . . . . . . . . . . . . 7
Meter Components . . . . . . . . . . . . . . . . . . 8
Keypad . . . . . . . . . . . . . . . . . . . . . . . . . 8
Setup Mode . . . . . . . . . . . . . . . . . . . . . .10
Measurement Procedures . . . . . . . . . . . . . . .15
Datalogger . . . . . . . . . . . . . . . . . . . . . . .22
Battery Replacement. . . . . . . . . . . . . . . . . .25
Troubleshooting . . . . . . . . . . . . . . . . . . . .25
Specications . . . . . . . . . . . . . . . . . . . . .26
Warranty . . . . . . . . . . . . . . . . . . . . . . . .32
Environmental Quality SD Card Logger 850071
Copyright ©2013 by Sper Scientic
ALL RIGHTS RESERVED
Printed in the USA
The contents of this manual may not be reproduced
or transmitted in any form or by any means electronic,
mechanical, or other means that do not yet exist or
may be developed, including photocopying, recording,
or any information storage and retrieval system
without the express permission from Sper Scientic.

4 5
INTRODUCTION
This Sper Scientic Environmental Meter with SD Card
Datalogger (Model 850071) is an extremely fast and
accurate meter with multiple functions. The meter reads
humidity, air temperature, air velocity, and measures
light in Lux or Ft-cd. Optional Type K/J thermocouple
probes available.
This meter features a real time SD memory card
datalogger. Standard, portable SD memory cards provide
unlimited data storage and upload pre-formatted data
directly to Excel. Each data set includes the measured
value along with the time and date. Sampling time can be
set from 1 second to 3600 seconds. Alternatively, manual
datalogging is available to record 99 readings.
FEATURES
• Functions as a light meter, anemometer, and humidity/
temperature meter. Optional adapter enables Type K/J
thermometer.
• Measures humidity in both %RH and temperature
• Displays air velocity in ve units of measure
• Lux or Foot Candles unit selection
• Zero Adjustment
• Highly accurate microcomputer circuit
• Direct upload of data to Excel
• SD memory card datalogger
• Manual datalogger option
• Internal clock and calendar
• Touch-tone
• Tripod mounting screw
• Built-in tabletop stand
• Maximum and Minimum
• Hold function
• Auto power o
• Low battery indicator
• Backlight

6 7
MATERIALS SUPPLIED
• Meter
• Sensor
• SD Card
• 6 AA Batteries
• Instruction Manual
• Hard Carrying Case
OPTIONAL ACCESSORIES
840058 USB Power Cable
840097 AC Adapter
840059 SD Card
840093 Field Tripod
840090 Water Resistant Instrument Pouch
POWER SUPPLY
This meter can be powered by six AA (1.5V, UM3)
batteries or an optional 9 Volt DC adapter.
See p. 28 for battery replacement instructions.
Plug the adapter into the power port labeled
“DC 9V,” located on the side of the meter.
Note…
When using the adapter, the meter will remain permanently
on and the POWER button will be disabled.

8 9
METER COMPONENTS
Keypad
1. LCD Display
2. POWER/ESC
3. FUNCTION /HOLD/
NEXT
4. REC/ENTER
5. SET/▼ (TIME
CHECK)
6. LOGGER/▲
(SAMPLING
TIME CHECK)
Side of Meter
7. RESET
8. DC9V Power
Adapter Input Socket
Back of Meter
9. Battery Cover
Screws
10. Tripod Mounting
Screw
11. Battery
Compartment
/ Cover Stand
1
Top of Meter
12. Type K/J
Thermometer
Socket
13. Probe Input
Socket
Bottom of Meter
14. SD Card
Socket
Sensor Probe
15. Anemometer
Vane
16. Humidity/
Temperature
Sensor
17. Light Sensor
7
13
28
14
3
9
15
4
10
16
5
11
17
612

10 11
SETUP MODE
The advanced Setup Mode allows you to customize the
following meter preferences and defaults:
• Real Time Clock
• Decimal Type
• Auto Power O
• Touch-Tone
• Thermometer Type K/J
• Temperature Units
• Sampling Time
• SD Memory Card Format
Note…
The setup functions can be performed under any
parameter, but not while utilizing the datalogger function.
Once selections are saved, the meter will default to the
selected preferences.
Entering Setup Mode
1. Press POWER to turn the meter on.
2. Press and hold SET for at least 2 seconds to enter
Setup Mode.
3. Press NEXT to cycle through the setup functions.
Note…
Press ESC to exit Setup Mode. The meter will return to
Normal Mode.
Real Time Clock
1. Enter the clock function from Setup Mode
(see above). “dAtE” appears on the LCD.
2. Press ENTER. The year will appear on the LCD.
3. Press ▲or ▼ to adjust the value. Press ENTER to
save the value.
4. Repeat Step 3 to adjust the month, date, hour,
minute, and second.
Note…
This procedure adjusts the meter’s internal clock. The
internal clock will function when the meter is turned o as
long as the batteries have adequate power.

12 13
Decimal Type
Although the decimal is commonly expressed as the “.”
symbol (i.e., 20.6 or 1000.53), some European countries
use a “,” symbol to represent the decimal (i.e., 20,6 or
1000,53). The meter defaults to the period symbol.
To adjust:
1. Enter the decimal type function from Setup Mode
(see page 11). “dEC” appears on the LCD.
2. Press ▲or ▼ to select Basic (.) or Euro (,).
Press ENTER to save the selection.
Auto Power O
The meter automatically turns o after 10 minutes of
inactivity. To disable this function:
1. Enter the auto power o function from Setup Mode
(see page 11). “PoFF” appears on the LCD.
2. Press ▲or ▼ to select yes (auto power o enabled)
or no (auto power o disabled). Press ENTER to
save the selection.
Touch-Tone
1. Enter the touch-tone function from Setup Mode
(see page 11). “bEEP” appears on the LCD.
2. Press ▲or ▼ to select yes (touch-tone enabled)
or no (touch-tone disabled). Press ENTER to
save the selection.
Thermometer Type K/J
1. Enter the thermometer type function from Setup
Mode (see page 11). “tYPE” appears on the LCD.
2. Press ▲or ▼ to select K or J. Press ENTER to
save the selection.
Temperature Units
1. Enter the temperature units function from Setup
Mode (see page 11). “t-CF” appears on the LCD.
2. Press ▲or ▼ to select C (degrees Celsius) or
F (degrees Fahrenheit). Press ENTER to save
the selection.
Sampling Time
The sampling time is the time allotted between successive
measurements. To adjust the sampling time (in seconds):
1. Enter the sampling time function from Setup Mode
(see page 11). “SP-t” appears on the LCD.
2. Press ▲or ▼ to adjust the value (1, 2, 5, 10,
30, 60, 120, 300, 600, 1800, or 3600 seconds).
Press ENTER to save the value.

14 15
SD Memory Card Format
This function will format the SD memory card to work
specically with your meter. New SD cards should always
be formatted before rst use. Formatting the SD card will
erase any previous memory on the card.
1. Enter the SD memory card format function from Setup
Mode (see page 11). “Sd F” appears on the LCD.
2. Press ▲or ▼ to select yes (format the SD memory
card) or no (do not format the SD memory card).
Press ENTER to conrm the selection.
3. If you selected yes in step 2 the display will show
“yES Ent.” Press ENTER again and the meter will
format the SD card.
MEASUREMENT PROCEDURES
Turning the Unit On/O
1. Press POWER to turn the meter on.
2. Press and hold POWER for ≥2 seconds to turn
the meter o.
Selecting the Function
Press and hold FUNC to cycle through the options
listed below. Release FUNC when you reach the
desired function.
Code on Display Function
An Air velocity/temperature
rH Humidity/temperature
tP Type K/J thermometer
LIgHt Light meter
Note…
The meter will default to the last function setting used when
it is turned o and on again.

16 17
Air Velocity and Air Temperature
1. Plug the anemometer probe plug into the probe
input socket.
2. Press POWER to turn the meter on.
3. Press and hold FUNC to cycle through the
options until “An” appears on the LCD. Release
the FUNC button.
4. Hold the probe handle and point the probe head
toward the air ow. The air velocity value appears
on the upper display and the air temperature value
appears on the lower display.
Selecting the Air Velocity Unit
1. Press and hold UNIT. The meter will cycle through
m/s, Km/h, mph, Knot, and FPM.
2. Release UNIT when the desired unit appears
on the LCD.
Note…
To change the temperature unit, see page 13.
Humidity and Temperature
1. Plug the probe plug into the probe input socket.
2. Press POWER to turn the meter on.
3. Press and hold FUNC to cycle through the
options until “rH” appears on the LCD. Release
the FUNC button.
4. The humidity value appears on the upper display
and the air temperature value appears on the
lower display.
Note…
To change the temperature unit, see page 13.
Type K/J Thermometer
Note…
The anemometer probe must be disconnected from the
meter to obtain accurate Type K/J readings.
1. Press POWER to turn the meter on.
2. Press and hold FUNC to cycle through the
options until “tP” appears on the LCD. Release
the FUNC button.
3. Plug a thermocouple temperature probe (type K or J,
optional) into the type K/J thermometer socket. The
LCD will display the measurement value from the
temperature probe.

18 19
4. “K” or “J” appears on the LCD to indicate the type of
thermometer.
Notes…
When using the meter for the rst time, the meter
will default to K type thermocouple. See page 13 for
instructions on selecting the thermocouple type.
To change the temperature unit, see page 13.
Light Meter
1. Press POWER to turn the meter on.
2. Press and hold FUNC to cycle through the options
until “LIgHt” appears on the LCD. Release the
FUNC button.
3. Plug the probe plug into the probe input socket.
4. While holding the sensor handle, point the light
sensor directly toward (facing) the light source.
The light measurement will appear on the LCD.
Note…
This meter measures light in LUX or Foot Candles (Ft-cd).
To change the light unit, press and hold REC ENTER.
Release REC ENTER when the desired unit appears on
the LCD.
Zero Adjustment
During light measurement, if the display does not show
a value of 0 when the light sensor is completely covered,
zero adjustment is needed.
1. With the sensor covered, press LOGGER for
>3 seconds. “0” appears on the LCD.
2. Uncover the sensor to resume normal measurement.
Hold Function
1. When measuring any parameter, press HOLD to
freeze the reading on the display. “HOLD” will appear
on the LCD.
2. Press HOLD again to release the hold function.
“Hold” will disappear from the LCD.
Otros manuales para 850071
1
Tabla de contenidos
Otros manuales de Registrador de datos de Sper scientific