CHANGING LIGHT MODES PARTIAL KEYLOCK [FILT] DAILY FILTRATION TIME Once P.SAV mode is selected the begin
and end times of the PEAK power tariffs
When light is first turned on the keypad Press and hold this button combination Adjust the hours of filtration per day. must be set so the control knows NOT
will display the light mode menu until LOCK appears on the display: Filtration limits differ for type of pump: to operate during those peak hours.
showing current light mode in use. Circ Pump (2A or less) 1-24 hrs BGN Peak power begin time
Jet Pump (2spd or 1spd) 1-8 hrs END Peak power end time
Press or button to step
Repeat button combination to unlock.
through choice of light modes: [F.CYC] FILTRATION CYCLES
[W.CLN] AUTOMATIC SANITISE
Note: Once locked only pumps, blower, light
WHTE White Light and sanitise buttons can be used. Access This setting defines how often filtration Adjust the start time of the 10 minute
UCLR User Colour to all other buttons is disabled. cycles occur. Filtration can be set to run automatic daily sanitise cycle. Setting
FADE Fade Effect every 1/2/3/4/6/8/12 or 24 hrs can be adjusted from 0:00 to 23:59.
STEP Step Effect
SETUP MENU
Press button to confirm light [SNZE] SLEEP TIMERS [D.DIS] DEFAULT DISPLAY MODE
mode selection. The setup menu allows customisation
Used to disable automatic heating and
of the adjustable controller settings. Used to adjust the default display mode
filtration during certain times of day or
Dependant on light mode selected the Menu access and item adjustments are shown on the keypad. Setting choices:
night. Upon entering SNZE menu there
keypad will then display one of three carried out as follows: W.TMP Water Temperature
are four choices:
light mode option screens. S.TMP Set Temperature
Press and hold and buttons TIME Clock
1.SNZ Sleep Timer #1
CL:xx User Colour Number together until [MODE] is displayed. 2.SNZ Sleep Timer #2
L.SPD Light Transition Speed R.SET Reset timers to default
L.BRT Light Brightness [T.OUT] LOAD TIME OUTS
Press or to navigate through EXIT Exit sleep timer menu
setup menu items. All accessory loads (pumps & blowers)
Press or button to adjust Only one sleep timer needs to be set automatically turn off after a time out
however two timers are provided to
each setting. Press to enter item adjustment. period has elapsed. Adjust the time out
facilitate different sleep settings on period from 10-60 minutes.
different days. Each sleep timer setting
Press button to save each setting Press or to adjust setting. consists of a week day setting, start
and move to the next setting. time and stop time (refer below). [H.PMP] HEAT PUMP MODE
Press to confirm setting and exit.
Note: All light settings are saved for x.DAY Day(s) of operation Defines heat pump operating mode:
All setup menu items follow the same
future ON / OFF use. x.BGN Sleep timer begin time
adjustment procedure. Menu items that AUTO Heat & Cool
x.END Sleep timer end time
can be adjusted are as follows: HEAT Heat Only
Use the Up, Down & OK buttons to
FULL KEYLOCK COOL Cool Only
adjust and confirm each setting. OFF Heat Pump Disabled
[MODE] OPERATING MODES
Press and hold this button combination
until LOCK appears on the display: [P.SAV] POWER SAVE (off peak)
Operating modes effect heating and [H.ELE] ELEMENT BOOST
filtration behaviour. The choices are: Reduce operating costs by limiting Enables/disables SV electric element to
filtration and heating to occur during
NORM Normal heating & filtration boost heat pump heating if the water
Repeat button combination to unlock. o
ECON Heating only during filtration cheaper off peak power periods. There temperature is 2 C or more below set
AWAY Heating disabled. Filtration are three P.SAV modes: temperature point OR the heat pump
Note: Once locked if any button is reduced to 1hr p/day. OFF P.SAV disabled has been operating for more than 1hr.
pressed the key stroke will be ignored WEEK Mon-Thu (works like AWAY mode) LOW Off-peak filtration only
and the display will show LOCK. Fri-Sun (works like NORM mode) OFF Element disabled (heat pump only)
HIGH Off-peak filtration & heating ON SV element + heat pump
up down pump a
+ +
up down pump b
+ +