Spa Builders SC-CF-SBD Manual de usuario

OWNER'S MANUAL
SC-CF-SBD SPA SYSTEMS
INSTALLATION, INSTRUCTIONS & MORE!
TAKING OVER THE WAVES!
CLEARLY ADVANCED SPA SYSTEMS!™

Contents
Topics covered in this manual are as follows:
Warnings Warning instructions 3
General Information Safety instructions 7
Specifications General specifications 9
Electrical & temperature specifications 10
Keypad dimensions 11
Power box dimensions 12
Installation Keypads
• K-18 13
• K-19 14
Overlays 15
Power box 17
Connecting
• your pack to your spa 18
• keypad & probe 19
Optional wet-end fitting 20
Jumpers Jumper selection 21
Configuration Output connectors 23
Pump 1 24
Blower 26
Pump 2 / blower 27
Ozonator 28
Electrical wiring 29
Powering your pack
• with strain relief 30
• with conduit adaptor 31
Instructions Single pump system 33
Dual pump or pump & blower systems 36
Alarms 40
Error conditions 41
Miscellaneous Wiring diagram 43
Factory default settings 44

SC-CF-SBD Owner’s Manual2
Notes:

3SC-CF-SBD Owner’s Manual
Warnings
•The temperature sensor must be installed in order to read
the water temperature properly. Improper installation of
the sensor can cause overheating or insufficient heating of
the water. The spa manufacturer must verify if the
temperature measured by the sensor is the same as the
actual water temperature and that the sensor cannot be
affected by external conditions (ex: air temperature).
•This control is not suitable and cannot be used for gas
heater applications.
•This control must always be connected to a circuit
protected by a ground fault interrupter.
•Install the control on a solid surface to minimize mechanical
vibrations.
•The power input cable should always be secured in place
with a proper strain relief.
•A notice should be installed by the manufacturer on the
finished product to notify the end user to always check the
water temperature with his hand before entering the water
so as to prevent burns and other injuries which may result
from improper water temperatures.
•This control should not be installed in the proximity of
highly flammable materials.
•This control is not protected against water infiltration. It
should not be installed in a location or in a manner which
could lead to contact with water.
•The electrical load of connections to this control must not
exceed the ratings specified by Spa Builders Systems Group
Inc. Failure to ensure compliance with proper electrical load
specifications may cause hazardous operating conditions
and/or decreased the life span of the control.
Important Warning Instructions

SC-CF-SBD Owner’s Manual4
Important Warning Instructions
Warnings
•Use copper wiring only.
•This control is certified as a component only. The finished
product which will incorporate this control should be
certified by the proper agency as a finished product. In no
circumstances should the fact that the control is certified as
component be considered sufficient for the finished product
to comply with certification requirements. The manufacturer
is solely responsible for ensuring that the finished product
complies with all applicable laws and regulations.
•Ambient air temperature in the vicinity of the control
location should not exceed the maximum temperature
rating specified by Spa Builders Systems Group Inc.
•The spa elements, containing water exposed to cold air
(piping, pumps, valves, etc.) must be approximately at the
same ambient temperature as the power module of the
control to prevent adequately from water freezing.
•This control should be serviced by qualify personnel only.
•If a fuse must be replaced, it should be replaced only with a
fuse of the same type and rating.
•The control must not be altered or modified in any way.
•Do not connect any equipment to this control other than
equipment and or accessories that are specified or approved
by Spa Builders Systems Group Inc. for each output.
•This control should always be installed with the proper ori-
entation as per the specifications provided by Spa Builders
Systems Group Inc.
•Do not create any opening in the control.
•Do not extend temperature sensor cables.

5SC-CF-SBD Owner’s Manual
Warnings
•This control must be installed as specified in the Spa
Builders Systems Group Inc. product certification report.
•It is possible that an output fail in the "on" position.
Make sure that this cannot create any hazard.
•The spa must comply with the ‘kinetic heating test’
described in UL1563 standard section 47.2.: "While at the
maximum water temperature from the water temperature
test described in 46.1, a unit, covered as specified in 47.2.2,
shall be operated circulating water at the maximum flow
rate without the heater operating until thermal equilibrium
as defined in 45.8 is attained or until ultimate results occur.
Any blower shall not be operating and any air induction
control shall be closed. A blower that heats the water, if
provided, shall be operated. The results are acceptable if
the water at any tub inlet does not exceed 50°C (122°F)".
•Any ventilation openings on the pack must be free from
obstructions that could limit the ventilation flow rate.
•The user manual must specify that if the keypad is physically
damaged, the end user must not use the finished product
and the keypad should be replaced immediately.
•Do not submerge the temperature probe completely in
water. Only the stainless steel portion should be in contact
with water.
•This product is provided with a pre-calibrated pressure
switch. Make sure that the pressure switch setting is
adequate for your application.
•Should you have any questions with respect to any of the
foregoing or the reference materials mentioned herein,
please do not hesitate to contact us.
Important Warning Instructions

SC-CF-SBD Owner’s Manual6
Notes:

7SC-CF-SBD Owner’s Manual
GeneralInformation
Important Safety Instructions
Caution
Thismanual
Congratulations! You have purchased one of the finest spa
packs available. Take the time to carefully read these
instructions.
Low voltage or improper wiring may cause damage to this
control system. Read and follow all wiring instructions when
connecting to power supply.
This pack contains no user serviceable parts.
Contact an authorized service center for service.
All connections must be made by a qualified electrician in
accordance with the National Electrical Code and any state,
province or local electrical codes in effect at the time of the
installation.
RISK OF ELECTRICAL SHOCK!
If used with 120V, your pack must be connected only to a
grounded receptacle.
ElectricalHazard
Notice
Important

SC-CF-SBD Owner’s Manual8
Notes:

9SC-CF-SBD Owner’s Manual
General Specifications
Specifications
Description
Features
Fromkeypad
These packs are perfect for spas with one or two pumps (or
one pump and a blower), a heater, an ozone generator and
a mood light.
•Automatic time-out on all outputs
•3 digit LED display
•Digital temperature display
•Sensor failure detection
•Programmable filtering cycles
•High-Limit protection
•Pressure switch failure detection
•Current limiting option
•Freeze protection
•Temperature measurement within ±1°F
•Temperature set point
•Temperature display in °C or °F
•Spa light control (on/off)
•One or two-speed pump control
Tabla de contenidos
Otros manuales de Jacuzzi de Spa Builders
Manuales populares de Jacuzzi de otras marcas

Bestway
Bestway Lay-Z-Spa 54189 Manual de usuario

Jacuzzi
Jacuzzi ARGA ARG101C0110 Manual de lista de piezas

Morphy Richards
Morphy Richards Essentials PC4006 Manual de usuario

Softub
Softub PRESTIGE Manual de usuario

JNJ SPAS
JNJ SPAS SPA-318 Manual de instalación

KIRAMI
KIRAMI Comfort Family Manual de usuario