EVCS_Remote Node_ENGND04101 1.15
1.800.338.7337 / www.soundoffsignal.com
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
www.soundoffsignal.com/sales-support. If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the
automated
message).
Questions
or
comments
that
do
not
require
immediate
attention
may
be
emailed
to
[email protected].SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
2
SETTING NODE ADDRESS
To set the node addresses:
1.MomentarilyconnectpowertoPIN14.
2.AddressindicatorLEDwillwinktheaddress(1-5).
NOTE:
•Defaultaddressis1.
•Afteraddress1issetitwillcyclethroughtheaddressesuntilitgetsbackto1.
DIAGNOSTIC LED
•ThediagnosticLEDissteadyonwhenthedeviceispoweredupandrunningwithnoerrors.
•ThediagnosticLEDisoffwhenthedeviceisofforinsleepmode.
•ThediagnosticLEDwinkswhenthereisasystemfaultofthedeviceisinrmwareupgrademode.
•FaultconditionisreadbycountingthenumberoftimestheLED
“winks”on.Eachfaultconditionwillgenerateapatternwhereeach“wink”is250ms
off/250mson.ThepatternisterminatedbytheLEDbeingofffor2.5seconds.
•TheLEDwillwinkmultiplepatternswhenmorethanonefaultconditionisactive.
FAULT CONDITION PATTERNS:
1Wink-RPDUoutput(s)arefaulted
2Winks-Communicationfault
3Winks-Sourcevoltagelevelis<9VDC
4Winks-Sourcevoltagelevelis>16VDC
5Winks-Overtemperaturecondition
Bydefaultevenoutputsashalternatingwithoddoutputs.
Tech Specs
nERGY Control System Remote
Node
Input Voltage: 10-16Vdc(NegativeGround)
Maximum Input Current: 50 Amps (30Amps at 85°C)
Outputs (Sum of ALL used Outputs
Shall Not Exceed 50Amps)
4x10AmpSolidState,Switched
6x5AmpSolidState,Switched
IGN ON: Standby Current: 60mA
IGN OFF: Sleep Current: 0.34mA
Inputs:
4xTotal
3xActiveHigh/LowInputs
*1xActivehigh/LowInputw/SystemWakeup
Reverse Polarity Protection: NotProtected(ReversePolaritywillDestroytheDevices)
Transient Protection: Protected
High Voltage Protection: >16V;HighVoltageErrorCodeSet
Low Voltage Protection: <9V;LowVoltageErrorCodeSet
Operating Temp: -40˚Cto+65˚C(85°Cmaxcurrent=30Amps)
Dimensions: 6.0”x3.4”x.8”
Weight, Boxed: 13.2oz.
Weight, Device Only: 10.7oz.
Valid Input Threshold High: >8.0V
Valid Input Threshold Low: <1.5V
Hermeticallysealedprovidingprotectioninwetareas.
•Installfuseorbreaker(50Ampsmax.)onmainpowersupply.
•DoNOTconnectproducttostrobepowersupply.Productisself-contained;noexternalpowersupply
needed.
•FollowattachedWiringandInterconnectrequirements.
•Torque the provided M8 nuts with lock washer to a maximum of 7ft-lbs.
-Verify that the lockwasher is fully seated when assembled-
WARNING
*Input1canbeusedtosenseignitionstatusforoverallsystemoperation
Multi-colorlightsshouldbedrivenbyoutputswithinthesameoutputgroup
(Group1:1-5,Group2:6-10)toaligntiming.
Bydefaultevenoutputsashalternatingwithoddoutputs.