Software House iSTAR Edge Hoja de datos

1
System Components
iSTAR Edge is a smaller, cost effective, 2 or 4 reader iSTAR that can be powered over its
Ethernet connection using PoE, and is suitable for placement above or near the door. iSTAR
Edge can be clustered with other iSTAR Edges and iSTAR eXs.
UL has evaluated and approved firmware version 5.1.x.xxxxx where 'x' may indicate any
numeral representing minor revisions or debugging.
iSTAR Edge has:
8 onboard inputs plus 32 or 64* optional I8 inputs
4 onboard relay outputs plus 32 or 64* optional R8 outputs
2 onboard direct connect Wiegand reader connectors
3 serial ports for RMs, I8s, I8-CSIs, and R8s.
2 AUX power outputs for PIRs, etc.
* 4 Reader model supports 8 I/8s and 8 R/8s.
UM-245 Version A3
June 2011
iSTAR Edge
Installation Quick Start Guide
NOTE iSTAR Edge requires the following minimum versions:
C•CURE 9000 version 1.93 (for 2 or 4 reader models)
C•CURE 800/8000 version 10.0, 10.1 (for 2 reader model only)

Overview and Introduction
2
Overview and Introduction
Figure 1 shows a photograph of the iSTAR Edge with an optional PoE board and with an I8
and R8 mounted on the door.
Figure 1: iSTAR Edge Photo
The 4 reader model can be ordered with 2 RM-4s mounted on the door.
Figure 2 on page 3 shows an iSTAR Edge layout.
I8 R8
PoE
Ethernet
Tamper
Module
(I8 and R8 not included)
(Optional)

Overview and Introduction
3
iSTAR Edge Layout
Figure 2: iSTAR Edge Layout
4 Inputs
AUX Output
Wiegand
Connector 1
RM Port 1
Relay 1
4 Inputs
AUX Output
Connector 2
Wiegand
RM Port 3
RM Port 2
Relay 2 Relay 4
Relay 3
USB Host Ports
Power Fail Power E-net
Tamper
FAI Input
Low Batt
USB Device Port (Not used)
In Key Latch input

Overview and Introduction
4
Main Features Main features of iSTAR Edge include:
Storage
> 250k cards.
64 MB of RAM.
128 MB of onboard flash.
Power
Powered by
Ethernet connection: UL 294 Listed PoE or PoE Plus using optional add-on board
(edgePower). A UL Listed surge protector must be used with the PoE module. The PoE
board can supply either 12VDC or 24VDC to the relay outputs (selectable via a jumper
on the PoE board).
- or -
12/24V DC, from UL Listed apS power source or other UL 603 Listed, power-limited
power supply with appropriate ratings and a minimum 4 hours of standby power.
Provides up to 1.5A @ 12V unswitched to external devices:
Wiegand readers
RS-485 ports
Two 2-pin AUX power connectors for PIRs and motion sensors.
Provides power to relays:
Relays configurable to be wet or dry by jumper.
Wet Relays provide current at main input voltage (12 or 24V on PoE, 12 or 24V with
external DC supply).
Each wet relay is limited to 0.75A (at 12 or 24V).
Each dry relay is limited to 3.0A (at 12 or 24V).
Readers
2 or 4 readers total.
2 Wiegand connectors are available.
2 RMs are available to be configured for the 4 reader model to provide 4 Wiegand
connectors.
3 RS-485 serial ports are available.
Readers can be any combination of 2 from Wiegand ports and/or RMs on any of 3
serial ports.
I/O
8 general purpose inputs.
4 general purpose relays:
Dry or wet contact settable per relay by jumpers.
4-pin connectors to support NO/NC and dry/wet configurations.
2 reader model, 4- I8 and 4- R8 allowed to be configured on any of the three RS-485 ports.

Overview and Introduction
5
4 reader model, 8- I8 and 8- R8 allowed to be configured on any of the three RS-485 ports or
the optional 2 RM-4s.
Special purpose inputs:
Tamper (from enclosure door)
Main AC fail (from apS)
Low external battery (from apS)
FAI Supervision State (J40 F input)
FAI Relay Control
FAI Key Supervision State (J40 K input)
Onboard battery low
3 RS 485 serial ports.
USB Ports
2 USB host ports. (These are the wide and flat USB connectors used by memory sticks,
used when the iSTAR Edge is the host of the attached devices.)
1 USB device port. (This is the square connector used when the iSTAR Edge itself is the
client device.) (not currently used)
The only use of USB in the first version is to import encryption keys, in the same way as
iSTAR eX.
Communications
One 10/100 Ethernet port.
No secondary communication path.
Full 256 bit AES encryption, as with iSTAR eX
Can cluster with other iSTAR Edges
Can cluster with iSTAR eXs
FAI
Fire Alarm Interlock - When the F input is true, FAI activates relays that are enabled for
FAI by individual enable switches.
Latch option is available by switch control. If the selected relays are latched, they will be
cleared to normal by the key (K) input.
Onboard controls
LCD with backlight for diagnostics.
Rotary switch for diagnostics, as with iSTAR eX.
LEDs for serial, Ethernet, power and relay state.
Two power LEDs: one super bright LED that is on when the enclosure door is closed,
and one green LED that is always on when main power is present.
Relay activation LEDs are not affected by enclosure door.
NOTE The following 4 inputs to the host are determined by the firmware. There is no actual
wiring to the iSTAR Edge board.

Overview and Introduction
6
All other LEDs only turn on when enclosure door is open.
Reset button.
Switches for serial termination of RM ports.
Switches for selection of relays for control by FAI.
Switch for FAI Latch.
Jumpers for relay wet/dry control.
Housing
Enclosure is similar to RM 4e enclosure.
Mountable in existing apC/L enclosure.
Compliance
FCC, CE, EN50133, UL60950 by CB Scheme (International Safety) & RoHS.
NOTE For all compatible devices, see the iSTAR Edge Installation and Configuration Guide
(Doc. No. UM-236).

Pre-Installation Planning
7
Pre-Installation Planning
Pre-installation involves the following:
1. Checking equipment (hardware, software, power supply, and wiring).
2. Checking power, wiring, equipment clearances, and code compliance at the site.
3. Ensuring the proper tools are available.
Equipment Check
Verify that the contents of the shipped boxes match the packing lists. Contact Software House
if any items are missing or damaged.
The iSTAR Edge hardware does not include mounting hardware for an installation. Mounting
hardware depends upon the site and must be approved by a structural engineer or other
certified professional.
Software House recommends anchoring systems capable of sustaining a 20 lb. load.
Site Check
Ensure that the mounting site is ready:
Mounting dimensions
• The can is 12” by 12” (30.48 x 30.48 cm)
• Upper mounting holes are 9" (22.86 cm) center to center.
• Bottom mounting holes are 10.5" (26.67 cm) below the upper mount holes.
The site has been approved and all wiring complies with UL requirements and other
codes, as appropriate.
All preliminary site work is complete.
An appropriate power supply is accessible.
The site is clean and free of dust or other contaminants.

Pre-Installation Planning
8
iSTAR Edge Mounting Requirements
The mounting dimensions and board overlay are shown in Figure 3.
Figure 3: Mounting Requirements
Installation Tools
Antistatic floor mat, tabletop mat, and wrist strap.
Standard tool kit
3/32" (2.4 mm) screwdriver (supplied with iSTAR Edge)
Security screwdriver (contact Software House)
Small needlenose pliers; small Phillips screwdriver; wire strippers
5/16" (#10) nut driver (for securing shield wires to a ground stud)
(228.6)
9.00
(304.8)
12.00
(304.8)
12.00
DOOR 2
IN 1
IN 2
IN 3
IN 4
AUX 1
WIEGAND 1
RM 1
RELAY 1
RELAY 2
PWR
RM 3
10/100
RELAY 4RELAY 3
RM 2
WIEGAND 2
AUX 2
IN 8
IN 7
IN 6
IN 5
DOOR 1
LCD DISPLAY
OPTIONAL
POE MODULE
iSTAR
Edge
TEMPLATE
ENCLOSURE
INSTALL SHEET, iSTAR Edge,
MOUNTING TEMPLATE
8200-0910-01, REV A3
SHEET 2 OF 2, SCALE 1:1
DIMENSIONS IN INCHES
( )DIMENSIONS IN MM

Installation Requirements
9
Installation Requirements
iSTAR Edge Cabinet Requirements
The iSTAR Edge cabinet must conform to the specifications shown in Table 1.
Environmental Requirements
Table 2 shows the iSTAR Edge environmental requirements.
Table 1: Cabinet Assembly Specifications
Item Specification
Weight <10 lbs (<4.6 kg)
Height 12" (30.48 cm)
Width 12" (30.48 cm)
Depth 4.5" (11.4 cm)
Table 2: Environmental Requirements
Status Range
Operation 32° F (0° C) to 120° F (48.9° C)
Storage 4° F (-20° C) to 158° F (70° C)

Installation Requirements
10
Power Requirements
The standard iSTAR Edge uses a UL Listed 603 External Power Supply, such as the Software
House apS or uses a Power Over Ethernet (PoE) injector with UL listed surge protector.
To ensure adequate power, calculate the total power requirements of iSTAR Edge and its
related hardware, as follows.
Add the total current power for components in the system (modules, relays, optional
modules, readers, and wire resistance).
iSTAR Edge Components and Boards
Table 3 shows the power requirements of iSTAR Edge components and attached boards.
aRM-4 board has only been evaluated by UL with RM Series readers (RM 1,2,3)
bRM-4E boards have only been evaluated by UL for use with RM-DCM-2 enclosure.
iSTAR Edge Input Power Rating
The iSTAR Edge has the following input ratings when using an external power supply:
12 VDC, 3.8 A
24 VDC, 3.1 A
Individual/Total Loads
RS-485 Reader Power Outputs: 10.6-12.5 VDC, 1.5 A max each.
Wiegand Reader Power Outputs: 10.6-12.5 VDC, 350 mA max each.
Total of all Reader and AUX outputs combined (RS-485 & Wiegand) not to exceed 1.5 A
Four (4) activated relay coils = 100 mA, 25 mA/relay
One I/8 module – 12 VDC, total= 125 mA
One R/8 module – 12 VDC, total= 325 mA (125 ma + 25 mA for each active relay (max 4))
R/8 relay contact ratings – 30 VDC at 3A (resistive)
Table 3: Component and Board Power Requirements
Component/Board Current Draw at 12VDC
iSTAR Edge 400 mA with LCD - no load
RM-4 boarda80 mA without LCD - no load
180 mA with LCD - no load
RM-4E boardb125 mA - no load
I/8 board 125 mA - no load
R/8 board 150 mA - no active relays.
Add 20 mA for each active relay
Otros manuales para iSTAR Edge
1
Tabla de contenidos
Otros manuales de Lector de tarjetas de Software House

Software House
Software House SWH-4100 Manual de usuario

Software House
Software House SWH-400 Series Manual de usuario

Software House
Software House RM 4000 Series Manual de instrucciones

Software House
Software House RM2-4000-PI26 Manual de usuario

Software House
Software House SWH-4000 Manual de usuario

Software House
Software House SWH-4000 Manual de usuario