TTDZ2 Digital Thermostatic Head
User Manual
5
Mounting
1. The display will show the "PRP" message until the mounting position is achieved,
after which "INS" and the icon appear. The LED will blink green, pending
confirmation by the user.
2. If necessary, locate an appropriate adapter and mount it onto the valve.
3. Place the TTDZ2 on the ring and screw it until it reaches the correct position.
For the duration of the process, the message "INS" will remain visible on the
display.
4. If the installation is successful, the LED will remain green for 5 seconds, while
the display will show the default set temperature.
5. If the assembly fails, the display will show "ER1", the LED will remain red and a
notification will be sent to the APP.
Exclusion
Before starting the procedure for including the device in a Z-Wave network, make sure that
the MyVirtuoso Home gateway is in exclusion mode (refer to the relevant manual available
on the website www.myvirtuosohome.com/en/downloads ).
1. Hold down the key for 5 seconds. The display will show "LEA".
2. If the exclusion is successful, the display will show the number 0 as the Z-Wave
node ID and the LED will remain green for 5 seconds.
3. In the exclusion phase, the display will show the Z-Wave node ID and the LED
will remain red for 5 seconds.
Reset
1. Remove the batteries from the head and press the button. Holding it down, reinsert
the batteries: The display will now show "RES". Release the key: The LED will blink
green waiting for confirmation from the user.