1514
Your SLENDERTONE product is suitable for use by all healthy
adults. However, as with other forms of exercise, some care
is needed when using it, so always follow the points below
and read your user manual carefully before use. Some of the
points below are gender specific.
Please do not use if:
• You have an electronic implant (e.g. cardiac pacemaker or
defibrillator) or suffer from any other heart problem.
• You are pregnant.
• You suffer from cancer, epilepsy or are under medical
supervision for cognitive dysfunction.
•The unit is in close proximity (e.g. 1m) to shortwave or
microwave therapy equipment.
• You are connected to high-frequency surgical equipment.
• Wearing the device necessitates placement over areas at
which drugs/medicines are administered by injection (short
term or long term) e.g. hormone treatment.
Please wait before using your SLENDERTONE product until:
• At least six weeks after the birth of your baby (you must
consult your doctor first).
• One month after an IUD contraceptive device (e.g. coil) has
been fitted.
• At least three months after having a Caesarean (you must
consult your doctor first).
•The heavy days of your period have finished.
Please get your doctor’s or physiotherapist’s permission
before using your SLENDERTONE product if:
• You wish to use a SLENDERTONE belt and have a bad back. You
should also ensure the intensity is kept low.
• You have any serious illness or injury not mentioned in this
guide.
• You have recently had an operation.
• You take insulin for diabetes.
• You want to use it on a young child.
• You suffer from muscle or joint problems.
• Using the device as part of a rehabilitation programme.
When applying the pads and belt, always remember to :
• Place the pads and belt ONLY on the abdomen, as indicated
in this manual.
• Avoid placing the pads or belt on the front or sides of the
neck, across or through the heart (i.e. one pad on the front
of the chest and one on the back), in the genital region or on
the head. (Other toning units are available for other areas of
the body - details are available at www.slendertone.com or
from your local retailer)
• Avoid any recent scars, broken or inflamed skin, areas of
infection or susceptibility to acne, thrombosis or other vas c ular
problems (e.g. varicose veins), or any parts of the body
where feeling is limited.
• Avoid areas of injury or restricted movement (e.g. fractures
or sprains).
• Avoid placing the pads directly over metal implants.
Possible adverse reactions:
• A small number of isolated skin reactions have been
re p o rte d by people using muscle stimulation devices, including
allergies, a prolonged reddening of the skin and acne.
• On ve ry rare occasions, first-time users of EMS have re p o rt e d
feeling light-headed or faint. We recommend that you use the
product while seated until you become accustomed to the
sensation.
To reposition pads during a session:
• Always pause the programme currently running, unfasten
the belt and then refasten it behind your back once the
p o s ition of the pads has been adjusted.
After strenuous exercise or exertion:
• Always use a lower toning intensity to avoid muscle fatigue.
Contact the careline if:
• Your unit is not working correctly. Do not use it in the
meantime.
• You experience any irritation, skin reaction, hypersensitivity
or other adverse reaction. You should, however, note that
some reddening of the skin can appear under the belt during
and for a short time after a session.
Note:
• An effective treatment should not cause undue discomfort.
Important:
• Keep your unit out of the reach of children.
•The studs and pads must not be connected to other
objects.
• Do not use your unit at the same time as any other device
which transfers an electrical current into the body (e.g.
another muscle stimulator).
• Cease using your unit if you are feeling light headed or
faint. Consult your doctor if this happens.
• Do not touch the pads or metal studs while the unit is
switched on.
• Do not use while driving, operating machinery or cycling.
• For first time users, muscle stimulation can be an unusual
sensation. We recommend that you begin with low stimulation
intensities to familiarise yourself with the sensation before
progressing to higher stimulation intensities.
• For hygiene reasons the belt is for use only by one person.
Do not share your belt with anyone else.
• Do not over exert yourself when using muscle stimulation.
Any workout should be at a level comfortable for you.
• Do not use your unit if you are wearing a belly-button ring.
Remove the ring before you begin a session.
•SLENDERTONE will not accept responsibility if the guidelines
and instructions supplied with this unit are not followed.
N.B. If you are in any doubt about using your SLENDERTONE
belt for any reason, please consult your doctor before use.
Section 7 lists the important information which must be read before using your toning belt.
Caring for your unit
Your unit should not be allowed to get wet or be left in exc e s s i ve
sunlight. It may be cleaned regularly using a soft cloth, lightly
dampened in soapy water. Do not allow the interior of yo u r
unit to become wet. Do not use detergents, alcohol, spra y
a e ros ols or strong solvents on your unit.
Access to the interior of the unit is not required for maintenance
purposes.
If your unit is damaged, you should not use it but should return
it to SLENDERTONE or your local distributor for replacement or
repair. Repairs, service and modifications may not be carried out by
any one other than qualified service personnel authorised by
SLENDERTONE.
IMPORTANT:Under no circumstance should anything other than
the correct type of batteries – (rechargeable batteries 3.6V
NiMH) be used with your unit. These can be purchased from the
SLENDERTONE careline.
Disposing of the pads and batteries
Used pads and batteries must never be disposed of in a fire but
in accordance with your country’s national laws governing the
disposal of such items.
NOTES:The signal gradually increases to a peak intensity level at
the start of the contraction phase (i.e. ramp up) and gradually
decreases to nothing at the start of the relaxation phase (i.e.
ramp down). When the symbol is flashing, the stimulus is
significantly reduced.
Accessories:
You can purchase all accessories at www.slendertone.com.
When ordering new pads, only use those carrying the SLENDER-
TONE brand. Any others may not be compatible with your unit
and could degrade the minimum safety levels.
Adhesive Pads (each pack contains):
•1 large adhesive pad Type 706 or 709
•2 small adhesive pads Type 707 or 710
SLENDERTONE SYSTEM-ABS Female Belt (E :10)
SLENDERTONE SYSTEM-ABS Male Belt (X :10)
SLENDERTONE SYSTEM Shorts
SLENDERTONE Belt Extension
Battery pack (3.6V, NiMH)
Battery charger (2504-0303)
Product Type: 390
Intended use: Muscle stimulator
Waveform: Symmetrical bi-phasic square waveform when meas-
ured into a resistive load.
Environmental Specifications:
Operating: Temperature Range: 0 - 35°C (32 - 95°F)
Humidity: 20 - 65 % RH
Storage: Temperature Range: 0 - 35°C (32 - 95°F)
Humidity: 20 - 85 % RH
Description of your unit’s symbols:
There are a number of technical markings on your unit. These
can be explained as follows:
The unit and belt are manufactured for Bio-Medical Research
Ltd, Parkmore Business Park West, Galway, Ireland.
The unit re q u i res 1 x 3.6 volt (NiMH) DC battery pack DC is
i n d icated by the symbol:
The Output Frequency indicates the number of pulses per second
t ransmitted by the unit. This is measured in hertz, which is
indicated by “Hz”.
Output (RMSA) means the maximum output root mean square
current for each channel.
Output (RMSV) means the maximum output root mean square
voltage for each channel.
This symbol means “Attention, consult the accompanying
documents”.
This symbol means type BF equipment.
This symbol on your unit is to indicate conformity
to the requirements of the Medical Device Directive
(93/ 42/EEC). 0366 is the number of the notified
body (VDE).
SN stands for ‘serial number’. Inside the box, on the back of
the unit is the serial number specific to this unit. The letter
preceding the number indicates the year of manufacture, where
“L” denotes 2006, “M” denotes 2007 etc.
The belt’s batch number is represented on the belt packaging,
by the number corresponding with the LOT symbol.
Rated Outputs – Voltage/Currents: E :10 and X :10
Parameter 500Ω1KΩ1K5Ω
Output RMSV 6.4V 12.7V 12.7V
Output RMSA 12.7mA 12.7mA 8.5mA
Output Frequency 50-70Hz 50-70Hz 50-70Hz
DC Component: Approx. 0 C 0 C 0 C
Positive Pulse Width: 200-300µs 200-300µs 200-300µs
Negative Pulse Width: 200-300µs 200-300µs 200-300µs
Interphase Interval: 100 µs 100 µs 100 µs
Attention:
This unit can deliver currents in excess of 2mA/cm2if used with
incorrect electrodes.
NOTE:In accordance with the laws within the member state, safety
testing on the device should be carried out every two years.
NOTE:In compliance with German law, product safety testing must
be conducted every two years by an authorised test service.
At the end of the product lifecycle, do not throw this
produc t into the normal household garbage, but bring
it to a collection point for the recycling of electronic
equipment.
Some product materials canbe re-used if you bring them
to a recycling point. By re-using some parts or raw
materials from used products you make an important
contribution to the protection of the environment.
Please contact your local authorities if you need more
information about collection points in your area.
Waste Electrical and Electronic Equipment can have
potentially harmful effects on the environment. Incorrect
disposal can cause harmful toxins to build up in the air,
water and soil and can be harmful to human health.
Section 8 is where you will find advanced technical information on your SLENDERTONE SYSTEM-ABS.
!
0366