Installation hints
For a proper installation simply comply with the following hints:
• Do not exceed the rated current of the device;
• Do not expose the device to external heat;
•
Match the device with a proper glass cover plate (14013.XX, 14023.X, 14033.XX,
14044.XX);
• Use a high breaking capacity fuse to protect the circuitry against overload or
short-circuit (cod. 10500.XX);
• Use the appropriate blank covers (part number 14350) to complete empty
spaces on mounting brackets.
• It is recommended to install the cover plates before power on.
• Do not reverse the connection polarity.
Data Specifications
Mains supply: ................................................................................12-24V AC-DC
Frequency: .........................................................................................50Hz ± 10%
Standby consumption: ......................................................................17mW@12V
Standby consumption: ......................................................................34mW@24V
Standby current: ...............................................................................1.4mA@12V
Standby current: ...............................................................................1.4mA@24V
Sensor Area: ........................................................................1 sensor of 590 mm²
Standard: ....................................... EN 60669-1:1999 + A1:2002 + A2:2008
EN 60669-2-1:2004+A1:2009 + A12:2010
In compliance with Community directives: 2014/35/EU (Low voltage)
2014/30/EU (Electromagnetic compatibility
Maximum Load current ....................................................................................2A
Operating temperature: ...........................................................................0 - 35°C
Relative humidity: .........................................................................................90%