Switching contact of relay 1:
Terminals W0 and W2
(n.o. contacts)
• Please number through the
EKC 601-... and/or EK 601-... you
wish to read in starting with no.
001.
9
System with EC 602-... and
1 ELM 611-... to actuate for example
1 door release via relay 1. The door
release is to stay switched on for 3
secs.
Use the programming button to
access the main menu.
Press the scroll button to enter the
Key card menu.
Use the programming button to
access the programming point
„Card input“.
Use the programming button to
enter the programming level.
Holding the EKC/EK 601-... you
wish to read in, approach the
reading module ELM 611-... at
which both LEDs are alight. Hold the
EKC/EK 601-... with the number 001
in front of the ELM 611-...
Once the card has been read in, the
green LED 1 flashes for one second
as a confirmation.
Read in further EKC/EK 601-... units
in ascending numerical sequence in
the same way.
After reading in the 999th EKC/
EK 601-..., the red LED flashes while
the green LED is continuously alight.
Continuous display
Press the programming button
Display
Press the scroll button twice
Display
Press the programming button
Display
Press the programming button
Display
Programming Example
with 1 ELM 611- ...
OK
OK
OK
It is not possible to read in any
further EKC/EK 601-... units.
If, for example, you have read in 10
EKC/EK 601-.. units you will see the
following display at the EC 602-...
(illustrated on page 10):
SSS Siedle
EC 602-02 V2.xx
SYSTEM
= Next OK = Prog
Key card
= Next OK = Prog
Card input
ESC = Cancel OK = Prog
= New OK = Save
Card 001 NEW