2. Introduction
2-1. Preliminary check
The controller has undergone sufcient quality control inspections, but you should check the specication code, inspect the
controller and make sure you have all the accessories to make sure nothing is missing or damaged.
Compare the specication code on the case with the following to make sure it is the product you ordered.
2-1-1. Specication code check
Item Code Specications
1. Series AR18 - DIN 96 x 96 digital controller
2. Measured values 1Equipped with indicator (red) 4 digits Character size 14.3 mm
0Not equipped with indicator
3. Input □□□ See Measuring Range Codes.
4. Control mode
1One setting, two-position type DF: 0.1 – 9.9% FS (Control output 2 cannot be selected)
2Two setting, two-position type DF: 0.1 – 9.9% FS (alarm output cannot be selected)
3 Three-position type DF: 0.2% FS DB: 1 – 99% FS (Control output is Y–N xed)
5. Control output 1
To select three-position, select “Y.”
Y - Contact 1c 240 V AC 5A / resistive load 2A / inductive load
P - SSR drive voltage output / 12 V±1.5 V DC (max. load current 30 mA) *1
6. Control output 2
To select one-setting, two-position type, select “N.”
To select two-setting, two-position type, select “Y” or “P.”
To select three-position type, select “N.”
N Not equipped
YContact 1c 240 V AC 5A / resistive load 2A / inductive load
P SSR drive voltage output / 12 V±1.5 V DC (max. load current 30 mA) *1
7. Alarm output (optional)
To select two-setting, two-position type, select “0.”
0Not equipped
1
Higher and lower limit deviation 2 points,
no standby action
Contact 1a 240 V AC 2A / resistive load
Hysteresis: 0.2% FS xed
Setting range
Higher limit alarm
Without decimal point: 0 – 99, no
With decimal point: 0.0 – 99, no
(Note that decimal points cannot be
set for readings of 10 or higher.)
Lower limit alarm
Without decimal point: no, -99 – 0
With decimal point: no, -99 – 0.0
(Note that decimal points cannot be
set for readings of -10 or lower.)
2
Higher and lower limit deviation 2 points,
standby action
Contact 1a 240 V AC 2A / resistive load
Hysteresis: 0.2% FS xed
8. Analog output (optional)
0None
3 Voltage 0 – 10 mV DC, output resistance 10Ω Output type: measured value
Output range: same as
measuring range (xed) *2
4Current 4 – 20 mA DC, load resistance 300Ω max.
6Voltage 0 – 10 V DC, load current 2 mA max.
9. Front panel J Japanese
10. Remarks 0 Without
9 With
2-1-2. Accessories check
Unit seal: 1
Instruction manual: 1
2-2. Notes on use
Do not operate the front panel keys with hard or pointed objects. Always press the keys lightly with the tips of your ngers.
To clean, wipe lightly with a dry cloth. Do not use solvents such as thinner.
*1: For SSR drive voltage output,
“heating action only.”
*2: Specication for lower limit value/
higher limit value within measuring
range is possible (specify when
ordering).
■ Terminal cover (Sold separately)
Type Mounting method
For AR18 QCR007 One-touch mount
(1 set contains 2 covers)
In the event you want to inquire about a product defect, missing accessory
or other matter, please contact your nearest Shimaden dealer.
CAUTION
Supplementary explanation: The table below indicates the summary of the specications of
“4. Control mode,” “5. Control output 1” and “6. Control output 2” which are shown on the above table.
Item Code Specications
4. Control mode
5. Control output 1
6. Control output 2
1Y-N One-setting, two-position type DF: 0.1 – 9.9%FS (contact output)
1P-N One-setting, two-position type DF: 0.1 – 9.9%FS (SSR drive voltage output)
2Y-Y Two-setting, two-position type DF: 0.1 – 9.9%FS (contact output + contact output)
2Y-P
Two-setting, two-position type DF: 0.1 –9.9%FS (contact output +SSR drive voltage output)
2P-Y
Two-setting, two-position type DF: 0.1 –9.9%FS (SSR drive voltage output +contact output)
2P-P
Two-setting, two-position type DF: 0.1 –9.9%FS (SSR drive voltage output +SSR drive voltage output)
3Y-N Three-position type DF: 0.2%FS DB:1 –99%FS (contact output)
【
【