Secure SSP 301 Instrucciones de funcionamiento

SSP 301 Z-Wave
Switch and Repeater
1
User and Installation Instructions
BGX501-920-R03

out of range
controller cannot
communicate directly
with device
SSP Repeater
Z-Wave
Controller
Lamp Load
2
SSP 301
The Secure SSP 301 is a switch and repeater
that forms part of a Z-Wave Plus™ home
automation network. The SSP 301 is a mains-
powered device that will switch (power
On/Off) a connected appliance either by the
Z-Wave network or manually by pressing its
integrated button.
The SSP 301 acts as a repeater in a Z-Wave
network by helping messages from other
devices reach there destinations.

The SSP 301 is a fully compliant Z-Wave
Plus™ device that will work with other
manufacturer's Z-Wave devices.
Installation
Step 1: Unpack, and
insert the SSP 301
into the wall socket.
Ensure that the red-
coloured network
status LED is
flashing (once per
second).
Note: If the network
status LED is not flashing check the following.
ŸEnsure that the wall socket switch is on.
ŸPress the top button, the relay status LED
should switch ON and glow green.
ŸIf the relay status LED does not glow then
the device is not functioning.
3
Button
Relay
Status
LED

ŸIt is possible that the SSP 301 was part
(joined) of another network previously; if so,
exclude it first before attempting to include onto
a new netwrok. Refer to step-2 for the exclusion
process.
ŸAvoid locations alongside or behind large
metal surfaces that could interfere with the low
power radio signals between the unit and the
controller.
Step 2: Including and Excluding a Device
To include the SSP 301 onto a network, put the
controller into inclusion
mode. Now, press and
hold the button on SSP
301 for 4 to 7 seconds
t h e n r e l e a s e . T h e
network status LED will
start flashing (twice per
second) on successful
s t a r t o f i n c l u s i o n
process.
4
Note: Inclusion means add
and exclusion means delete.
Relay
Status
LED Relay
Status
LED

Note: Refer to the controller's manual for
controller relevant actions.
On successful inclusion the LED will turn off.
The total process can take up to 20 seconds
(Refer to the “Technical specifications –
Radio” section for details).
If the device fails to join the network it will go
back to the factory default state and the
Network status LED will start flashing once
per second.
If there is an issue with RF communication,
re-locate the device and repeat the inclusion
process.
To exclude the SSP 301 from a network, put
the controller into exclusion mode (refer to
controller instructions) and follow the same
sequence as per the inclusion process for
include node. After successful exclusion the
network status LED will start flashing once
per second, and the device will reset to
factory default. 5

Note: Exclusion only works when the device is
in direct range of the controller (no repeater
allowed)
Associating SSP 301 in a Z-Wave Network
(follow step 3 to 5)
Note: Association process only works after the
device has been included onto network
Step 3: Put the controller into Association
Mode.
Note: Some controllers can automatically
associate. Always check with the
manufacturer's manual.
Step 4: Identify the device to the controller by
sending the node information, to do this press
and hold the SSP 301 button for more than 1
second, but less than 4 seconds, and then
release.
If exclusion fails, the SSP 301 network status
LED will turn off after about 5 seconds.
Step 5: The controller should confirm
association when the process is successfully
completed this depends on your controller see
the manufacturers documentation supplied with
your controller for this information.
6

Appliance Socket
Press the SSP 301 button (less than one
second) to supply power to its socket. By
default, the green LED will be lit when the
supply is On.
The socket type will vary with country. The
figure shows the UK variant. Ensure that the
appliance plug is firmly plugged into the
appliance socket.
7
Combined
Button &
LEDs
Relay Status LED: ON
power switched
to front socket
Relay Status
LED
*Socket type
will vary with
country

Button
press time Operation LED status
Less than
1 second
1-4 seconds
4-7
seconds
7-11
Seconds
Toggles supply to
socket outlet
Send NIF (used
for Association)
Inclusion/exclusion
SSP 301 resets to
factory default
(Refer 'Device
Reset Locally'
command class)
Toggles green
LED
NA
Red LED flashes
twice per second
Red LED flashes
once per second
Button Actions
8

Z-Wave Plus command classes
Z-Wave Plus
Device Classes
Generic Binary Switch
Specific On/OFF Power Switch
Basic Routing Slave
Implemented
Device Class
Command Class Commands Supported
Mapped on Binary Switch Command class (V1)
Binary switch (V1) Get
Manufacturer Specific
(V2)
Manufacturer ID = 0x0059
Product Type ID = 0x000E
Product ID = 0x0001
(UK & EU)
Product ID = 0x0002 (ANZ)
Report
Set
Basic (V1) Get
Report
Set
Report
Get
9

Version (V2)
Version Command Class Get
Report
Get
Version Command Class
Report
Association (V2) Set
Get
Report
Remove
Supported Groupings Get
Supported Groupings Report
Specific Group Get
Command
Specific Group Report
Command
Product supports one association group that have
maximum of 4 nodes.
Set
Get
Report
Configuration (V1)
10
Report
Device Reset Locally (V1)
See Configuration Parameters for details
Please use this procedure only when the primary
controller is missing or otherwise inoperable,