Telcosat RBB 850 Guía de instalación

Document use is restricted to that described on the cover
1
OPERATION & MAINTENANCE MANUAL
CELLULAR CDMA/GSM/WCDMA
REPEATER MODEL RBB 850
Any modifications to this device will void FCC and IC approvals.

TELCOSAT RPT 900
Document use is restricted to that described on cover
2
BLANK PAGE

TELCOSAT RPT 900
Document use is restricted to that described on cover
3
OPERATIONS & MAINTENANCE MANUAL
CELLULAR REPEATER MODEL RBB 850
TELCOSAT RBB 850
The information set forth in this document and all rights in and to inventions disclosed herein, and
patents which might be granted thereon disclosing, employing or covering the materials, methods,
techniques or apparatus described herein are the exclusive property of Telcosat Inc.
This document is an operation and maintenance manual. No disclosure or reproduction of the
information or drawings shall be made of any other purpose without the prior written consent of
Telcosat Inc. Use of the information contained herein to fabricate or assemble any item in whole or in
part is expressly prohibited.
Any modifications to this device will void FCC and IC approvals.
A Canadian Company
Telcosat Inc.
116, 1919 –27th Ave NE,
Calgary, Alberta, Canada. T2E 7E4
TEL (403) 291-4031
FAX (403) 291-3059

TELCOSAT RPT 900
Document use is restricted to that described on cover
4
SAFETY SUMMARY
High voltage is used in the operation of
this equipment. Death on contact may
result if personnel fail to observe the
following safety precautions:
Only qualified trained personnel can install this equipment. Electrical connection and installation must
meet your local Electrical Safety Installation codes.
Prior to any maintenance or inspection of this device disconnect the power supply.
Do not remove covers or access plates on the equipment unless you are a trained technician and
authorized to carry adjustment and maintenance for this apparatus.
When installing antennas always be aware of high voltage overhead power lines. Contact with power
lines will result in severe injury and or death.
To prevent electrical shock or damage to the equipment, do not operate the repeater until you
thoroughly understand the operation and function of all controls, indicators, and connectors.
The RBB850 Repeater weighs approximately 25 lbs/ 12 kilograms. The repeater must be attached to the
appropriate supporting device using nuts, bolts and lock washers. Material grade, must be a minimum
Grade 5, 5/16th” (6mm) diameter and corrosion resistant.
FIRST AID
In case of electrical shock:
THIS PERSON COULD STILL BE IN CONTACT WITH ELECTRICAL POWER. DO NOT TOUCH THIS PERSON
BEFORE YOU INSULATE YOUR SELF FROM THE ELECTRICAL SOURCE.
Turn off the electrical power.
If you cannot turn off the electrical power, pull, push, or lift the person to safety using a dry wooden
pole, a dry rope, or some other insulating material. Do not use any metallic objects to move this person.
After the injured person is no longer in contact with the electrical source, obtain/perform immediate
medical attention.

TELCOSAT RPT 900
Document use is restricted to that described on cover
5
TABLE OF CONTENTS
SAFETY SUMMARY----------------------------------------------------------------------------------------------------------- Page 4
FIRST AID------------------------------------------------------------------------------------------------------------------------Page 4
TABLE OF CONTENTS--------------------------------------------------------------------------------------------------------Page 5
CHAPTER 1
1.1 GENERAL Page e
1.2 INTRODUCTION Page 6
1.2.1. MATERIALS Page 6
1.2.2 RPT 900 APPLICATIONS Page 6
1.3 RPT 900 SPECIFICATIONS Page 7
1.4 TECHNICAL ASSISTANCE Page 7
OPERATIONAL OVERVIEW CHAPTER 2 Page 8
2.1 GENERAL Page 8
2.2 REPEATER MODULE RF PATHS Page 8
2.3 DETAILED TECHNICAL RF SIGNAL PROCESSES Page 9
2.4 AC POWER DISTRIBUTION Page 10
INSTALLATION CHAPTER 3
3.1 WARNING Page 10
3.2 TOOLS REQUIRED Page 10
3.3 ANTENNA REQUIREMENTS Page 11
3.4 ANTENNA ISOLATION & COAX CABLES Page 12
3.5. INSTALLING YOUR REPEATER Page 13

TELCOSAT RPT 900
Document use is restricted to that described on cover
6
3.6 POWER AND ATTENUATOR SWITCH SETTINGS Page 14
3.7 RSSI INDICATOR AND SIGNAL LEVELS Page 14
3.8 ALIGNING YOUR ANTENNA Page 14
3.9 ADJUSTING UPLINK POWER Page 15
WARRANTY REPAIR CHAPTER 4 Page 16
4.1 WARRANTY Page 16
4.2 LIMITED WARRANTY Page 16
EQUIPMENT STORAGE CHAPTER 5 Page 17
APPENDIX A TECHNICAL SPECIFICATIONS TABLE ONE Page 18
APPENDIX A RF EXPOSURE LEVELS Page 19
APPENDIX B RETURN GOODS PROCEDURE Page 20
B2. Returned Goods Procedure Page 20
B3. Shipping Procedure Page 20
B4. Returned Shipments Page 20
B5. Repair / Return Status Page 20
LIST OF FIGURES
Figure 1-1 RPT 900 in a typical repeater remote site set up configuration Page 7
Figure 2-1 RPT 900 UP and DOWNCONVERTER Blocks Page 9
LIST OF TABLES
Table 1- Technical Specifications Page 19

TELCOSAT RPT 900
Document use is restricted to that described on cover
7
CHAPTER 1
SCOPE
1.1 GENERAL
The TELCOSAT RBB 850 Cellular Repeater (consisting of UPLINK and DOWNLINK bidirectional system)
contains operational and maintenance information.
Chapter 1 outlines the manual contents, with description and general application notes
Chapter 2 contains an operational and product overview.
Chapter 3 contains of antennas, antenna isolation, installation tools.
Chapter 4 contains information on the software GUI, connecting to a network, configuring the
software and configuring the RBB850 repeater.
Chapter 5 contains warranty information
Appendix A contains FCC/IC RF Exposure Requirements and RBB850 repeater specifications.
Appendix B contains the return goods procedure.
1.2 INTRODUCTION
The TELCOSAT RBB 850 is a bidirectional amplifier system consisting of UPLINK and DOWNLINK
amplifiers.
When conventional cellular communication systems cannot penetrate a structure, or reach a target
area, such as inside buildings, parking structures, tunnels and remote areas, other methods and or
equipment are required.
To overcome coverage issues cellular repeaters can be deployed. Repeaters manufactured by Telcosat,
Model RBB850 will alleviate many of these coverage issues.
The Telcosat RBB850 repeater has full remote control, monitoring and alarm feature, accessible over the
Internet or IP network. The RBB850 has an internal web interface and a user friendly GUI software
interface.
The GUI interface (Graphical User Interface) controls all functions of the repeater.
The RBB850 repeater also comes with digital power control and oscillation detection and control.

TELCOSAT RPT 900
Document use is restricted to that described on cover
8
1.2.1
Materials
The RBB 850 Repeater is enclosed in a weather proof enclosure. System comes with instruction manual
and attached power cord.
Fig. 1-1
Typical TELCOSAT INC remote location Site System
TELCOSAT RPT 900
bidirectional
Cable Grounding Kits
Fig. 1-1 TELCOSAT INC Remote Location Site Configuration
External wall or tower mount antenna/YAGI
Cable Grounding Kits
Fill-in Antenna
Fig. 1-1
1.3 RBB 850 SPECIFICATIONS
Appendix A contains the TELCOSAT RBB 850 Repeater Specifications.
1.4 TECHNICAL ASSISTANCE
Technical assistance on the TELCOSAT RBB 850 Repeater is available through:
TELCOSAT Customer Service Center,
Phone: 1-403-291-4031.
Fax: 1-403-291-3059
EMAIL: inquiries@telcosat.com

TELCOSAT RPT 900
Document use is restricted to that described on cover
9
CHAPTER 2
OPERATIONAL OVERVIEW
2.1 GENERAL
The TELCOSAT RBB 850 provides service at cellular radio frequencies 824/849MHz & 869/894MHz.
Downlink RF signals from a donor cell site are routed through a pick-up antenna, through a Diplexer
then continues to be process by the amplifier chain. The RF signal is amplified and filtered to reject out-
of-band IM products and unwanted radio signals. The downlink RF is injected into a fill-in antenna
(coverage antenna) for null-area coverage.
The Up-link signals from mobile units are received into the coverage antenna of the repeater. The
incoming signal then passes through a Diplexer, then amplified in the Up-link modules and finally the
power amplifier. The Up-link process is the same as the Down-Link process.
2.2 OSCILLATION DETECTION
The RBB 850 has an oscillation detection function. Upon detection of oscillation the repeater will shut
down for a short duration, approximately 25 seconds. After 25 seconds the repeater will restart, reduce
the RF gain and determine if the repeater is stable. The repeater will continue this process until the
oscillations is eliminated. If oscillation cannot be eliminated the repeater will activate the disable mode
and will cease to transmit.
The repeater requires a power cycle to reset the auto oscillation detection process, or alternatively the
repeater can be reactivated via the GUI web interface.
RBB 850 REPEATER
LNA
DL PLL+VCO
DL RF BPF IF BPFIF Amp1
IF BPF
UL RF BPF
PA
UL PLL+VCO
IF Amp 2
-
Power
Det
uC
Area
fill
ANT
DL RF BPF Driver PA
Power
Det
RF Amp1
Dig
Att
Driver
Dig
Att 1
UL RF BPF
LNA
DL LO
UL LO
Dig Att Dl
Dig Att UL
Dig Att DL
Pout UL
Pout UL
TCXO
Pout DL
UL LO
DL LO
Donor
ANT
Figure 2-1 illustrated a simplified block diagram of the RBB 850 Cellular Repeater.

TELCOSAT RPT 900
Document use is restricted to that described on cover
10
2.3 AC POWER DISTRIBUTION
AC input power via a power cord which feeds a power supply that converts the AC to DC low voltage.
The DC power provides all the necessary requirements for the active components.
The repeater is equipped with a red LED power on light.
Power Supply Specifications,
-40c° to +50c° Operating Temperature Range
Short circuit, over power and over voltage protection
Input Power, 100-240 VAC
47/63 Hertz
Output Power, 12VDC/5AMPS
Approvals, UL, CUL, CE
CHAPTER 3
INSTALLATION
READ THESE INSTRUCTIONS PRIOR TO INSTALLATION
3.1 WARNING
Cellular Repeaters should be installed by fully trained technicians. Improper installation and excessive
RF power levels can cause interference with the operation of cellular towers.
Antennas must be mounted in a secure safe manner and according to safe working practices.
To protect your equipment, lightning protection hardware is recommended when installing a cellular
repeater unit.
Antennas must not be installed near overhead electrical power lines as this can cause serious injury
and or death.
Tabla de contenidos

















