SeaSoft Galaxy Manual de usuario

Galaxy Gateway manual rev 1.2
01. Introduction
02. Compatibility
03. Installation
04. Configuration
05. Panel configuration
06. Telnet
07. MQTT
08. KNX
09. Integration
10. Updating
11. Module reset
12. Worth knowing
13. Technical details

1. Introduction
Galaxy Gateway produces an interface between Honeywell Galaxy
line of intruder alarm panels. Since the panels do not expose all
data over SIA4 control or RS485, a combination is needed to get all
functionality.
A list of capabilities:
RS485 SIA4
Zone states X X
Zone alarm states X
Zone omit X
Output states X X
Output control X
RF detector states ( RF portal ) X
RF key fob states ( RF portal ) X
Group states X
Group control X
Group alarm states X
Virtual keypad X
Virtual rio’s X
NTP time synchronisation X
Device tampers X X
SIA3 reports X
DCM and Max door states X
Card number X
States being retrieved over RS485 is limited to the bus line the
module is connected to.

2. Compatibility
• Galaxy G3 series ( V5.xx )
- Control via onboard RS232 or E080
- RS485 listening and emulation
• Galaxy Flex series ( V1.xx )
- Control via A080
- RS485 listening and emulation
• Galaxy Flex (+) series ( V3.xx )
- Control via A083
- RS485 listening and emulation
• Galaxy Dimension ( V6.xx / V7.xx )
- Control via onboard RS232 or E080
- RS485 listening and emulation
• Galaxy G2 series
- No control possible
- RS485 listening and emulation
Panels Int
RS232 Eth RF
Portal
RF
Rio VKpd VRio Sia
Control
Dimension V E080 V V V V V
Flex V3 A083 V V V V
Flex V1 E080 V V V V
G3 V E080 V V V V
G2 V V V

3. Installation
The module can be powered from either POE or from the Panel
over a 12V supply next to the AB or AUX3 when available.
In order to use the onboard PSU to power the module set DIP2 to
ON.
RS485 -> connect A on the module to A on the Galaxy
connect B on the module to B on the Galaxy
RS232 -> connect TX on the module to RX on the Galaxy
connect RX on the module to TX on the Galaxy
The onboard tamper connection can be enabled by disabling DIP1.
This will enable the header pins and allow connection for an
external tamper switch. The activation of the tamper switch results
in the triggering of the tamper of a virtual keypad and is sent
back to the panel and over MQTT as a device tamper.
POE is not recommended as when using RS485 virtual keypad or
virtual rio emulation, if the module looses power, the panel will
report missing components. 2 missing components results in a
confirmed alarm!

4. Configuration
On first bootup, the module opens up an access point ( AP ) to
connect to for the initial configuration. This is a so-called Captive
Portal. As soon as the wifi connection is established, the AP will
close. To bring up the AP again, press the AP button on the module
or connect to the telnet server and command the AP to be started
from there.
-> telnet “module ip”
-> ap start

The Captive Portal allows for primary setup of either Wifi or Lan
connection. Upon selection of the interface, a choice for DHCP or
Static IP assignment is presented. After saving the settings, the
portal will close. Manually restart the module to start the actual
configuration. A web interface is presented to do this on the IP
address the module has received from DHCP or the Statically
assigned IP address.
When Wifi is enabled, Lan is disabled and visa versa.
WARNING: BEFORE MAKING ADJUSTMENTS, IT IS ADVISED
TO PUT THE PANEL IN ENGINEERING MODE
Since allot of the communication relies upon a unique id, both the
firmware version and unique id is displayed in the web
interface.
Various status columns display the status of the different
connections and automatically update every 15 seconds together
with the SIA3 Log.

▪NTP
When using SIA4 control with the panel, the option for NTP time
synchronisation becomes available.
In order for the NTP server from the internet to work, a DNS IP
address has to be configured. When using a local NTP server, the
IP address for that can also be directly entered.
Choosing your timezone will automatically update the DST settings.
Keep in mind that the DST settings will only be applied on the next
synchronisation, not when the actual time has changed.
The sync interval allows control over how often the panel needs to
be updated. The option “Forced” will not automatically do it, but
instead needs to be manually executed via the telnet command
“ntp”.

▪SIA4 Control
This allows the module to be setup to control the panel and retrieve
bulk status updates for zones, outputs and groups.
The method allows you to switch between RS232 and IP. The SIA4
pincode is the “remote pin” setting for the galaxy panels. By default
this is 543210 and can only be changed by using Remote Servicing
Suite.
The DIP8 setting is only valid when the panel is a 264 or 520.
Dipswitch 8 on main board allows for moving Rio1 on the main
board to a virtual rio 0. If this is enabled, the data being pulled is
different so if you have a 264 or 520, make sure the tick box is set
accordingly.

Below that, you can control the amount of data that will be retrieved
over SIA4. There is however a penalty to be paid, the more
enabled, the slower the refreshes. Each tick box represents an
additional query that needs to be sent.
The default should be good enough, but enable more / less as
desired. By default a compound feedback is requested when “open”
is not selected:
- 0 = closed / low res / high res
⁃1 = open / tamper / masked / fault
When “open” is selected, it retrieves the true open
and closed state. Tampers, masked etc are not processed unless
the extra options are selected.
By default only “alarms” and “omit” are ticked.

▪RS485 enable
When RS485 is enabled and connected, it allows for listening in
events on the galaxy bus for increased speed of zone detection but
also to emulate rio’s and a keypad.
The DIP8 setting corresponds to the same DIP8 setting at SIA4
control. If the module was setup to connect over SIA4 to the panel
and made a successful connection, it will pull the panel details and
adjust the options available automatically.
Selecting a keypad address will allow for a virtual keypad. Same as
for the rio’s. Multiple can be selected by holding the shift key.
Once selected, exit engineer mode on the panel for the additional
modules to be recognised.
Tabla de contenidos
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario