1. Menu program / delete codes (select button 1)
To store a user code (max 800) enter: code (from 2 to 5 digits), digit right arrow for channel 2 or digit left arrow for channel 1.
Example, to set the user code 12345 on the channel 2 digit: 12345
To delete a user code enter: code
Example to delete the user code 12345: 12345
The user code will be delated on both channel.
Note: Attempting to insert a code which is alredy present already will be reported as an error (5 beeps)
2. Backlight menu (press button 2)
+1+ Set backlight timeout to 10 sec after last button pressure;
+2+ Backlight off (turned on only during programming and flashing with valid code);
3. Passepartout Menu (select button 3)
With this function set, just press the button to turn the radio transmission on channel 1
And press the button to turn the radio transmission on channel 2, without having to enter the code;
+1+ Function on
+0+ Function off
4. Buzzer management Menu (press button 4)
+1+ Buzzer on;
+0+ Buzzer off.
5. Reset memory Menu (press button 8)
To confirm enter 8
6. MASTER code modification Menu (press button 9)
To modify the MASTER code enter: Master code (4 digits)
Example to set a MASTER Code 8888: 8888
Note: it is possible to exit the programming menu at any time by pressing 0
or waiting for The timeout of 20 seconds from the last use of the button.
7. Programming on OPEN
When set as Rolling Code Plus, the keybad can be codified and written with the
software SP40-V2, as for a normal Rolling Code Plus transmitter.
(See Fig.1 for programming with SP40-V2 and OPEN PLUS).
GENERAL NOTICE FOR THE INSTALLER AND THE USER
1. Read carefully these Instructions before beginning to install the product. Store these instructions for future reference
2. Don’t waste product packaging materials and /or circuits.
3. This product was designed and built strictly for the use indicated in this documentation.Any other use, not expressly indicated here, could compromise the
good condition/operation of the product and/or be a source of danger. SEA S.p.A. declines all liability caused by improper use or different use in respect to
the intended one.
4. The mechanical parts must be comply with Directives: Machine Regulation 2006/42/CE and following adjustments), Low Tension (2006/95/CE),
electromgnetic Consistency (2004/108/CE) Installation must be done respecting Directives: EN12453 and En12445.
5. Do not install the equipment in an explosive atmosphere.
6. SEA S.p.A. is not responsible for failure to observe Good Techniques in the construction of the locking elements to motorize, or for any deformation that
may occur during use.
7. Before attempting any job on the system, cut out electrical power and disconnect the batteries. Be sure that the earthing system is perfectly constructed,
and connect it metal parts of the lock.
8. Use of the indicator-light is recommended for every system, as well as a warning sign well-fixed to the frame structure.
9. SEAS.p.A. declines all liability as concerns the automated system’s security and efficiency, if components used, are not produced by SEAS.p.A..
10. For maintenance, strictly use original parts by SEA.
11. Do not modify in any way the components of the automated system.
12. The installer shall supply all information concerning system’s manual functioning in case of emergency, and shall hand over to the user the warnings
handbook supplied with the product.
13. Do not allow children or adults to stay near the product while it is operating. The application cannot be used by children, by people with reduced physical,
mental or sensorial capacity, or by people without experience or necessary training. Keep remote controls or other pulse generators away from children, to
prevent involuntary activation of the system.
14. Transit through the leaves is allowed only when the gate is fully open.
15. The User must not attempt to repair or to take direct action on the system and must solely contact qualified SEApersonnel or SEA service centers. User
can apply only the manual function of emergency.
2
16. The power cables maximum length between the central engine and motors should not be greater than 10 m. Use cables with 2,5 mm section. Use
double insulation cable (cable sheath) to the immediate vicinity of the terminals, in particular for the 230V cable. Keep an adequate distance (at least 2.5 mm
in air), between the conductors in low voltage (230V) and the conductors in low voltage safety (SELV) or use an appropriate sheath that provides extra
insulation having a thickness of 1 mm.
>>
>>>>
>>
>>>>
>>>> >>>> >>>>
>>>> >>>> >>>>
>>
>>>>
>>
>>>>
>
>>>>
>>
>>>>
>>
>>>>
>>
>>>>
>>
>>>>
>>
>>>>
>>
>>>>
>>
>>>>
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English
4
Programming connector: For
more information refer to the
Open manual.
Fig.1