31
WORKING TIMES SELF LEARNING
Fig. 1 Fig. 2 Fig. 3
Fig.4
The control unit is pre-set with the default settings, to start the control unit with the DEFAULT settings just keep
pressed the UP and DOWN buttons at the same time power supplying the control unit the display shows the
message “Init”.
The DEFAULT settings are shown in the Menues table.
NOTE: When using a magnetic limit switches in general; make sure that the control unit is set on magnetic limit switch before
learning.
MENU 104 - SELECT LIMIT SWITCH - “Magnetic”
1) Disconnect the power supply, release the motor (Fig. 1) and manually position the leaves or the beam on halfway (Fig. 3-4).
2) Reset the mechanical lock (Fig. 2)
3) Select 9 - PROGRAMMING on the display, press OK and than one of the UP or DOWN buttons. Now the gate will automatically execute a
closing, opening and reclosing cylce.
Note: If the motor starts in opening, remove and re-put power supply, select on the display 5 - REVERSE MOTOR. And through the UP and
DOWN button put it on ON, or if you have the Jolly 3 programmer, activate the motor and limit switch exchange function. If the motor starts in
closing and stops, remove the power supply and reverse the motor cables, then repeat the programming procedure.
4)The self-learning is done.
ATTENTION: This procedure is potentially dangerous and should only be performed by qualified personnel in safety conditions.
FUNCTION LOGIC
AUTOMATIC LOGIC
A start impulse opens the gate. A second impluse during the opening will not be accepted.
A start impulse during closing reverses the movement.
SECURITY LOGIC
A start impulse opens the gate. A second impulse during opening reverses the movement.
A start impulse during closing reverses the movement.
STEP BY STEP TYPE 1 LOGIC
The start impulse follows the OPEN-STOP-CLOSE-STOP-OPEN logic.
STEP BY STEP TYPE 2 LOGIC
The start impulse follows the OPEN-STOP-CLOSE -OPEN logic.
NOTE1 : To have the automatic closing in this logic it is necessary to set a pause time , otherwise all the logics will be
semi-automatic
NOTE2: It is possible to choose whether to accept or not the start in pause, by selecting in the MENU point 8-START IN
PAUSE and choosing ON or OFF. The default parameter is OFF.
DEAD MAN LOGIC
The gate opens as long as the START button of opening is pressed; releasing it the gate stops. The gate closes as long as the
button connected to the PEDESTRIAN START is pressed; releasing it the gate stops. To execute complete opening and/or
closing cycles the related pushbuttons must be constantly pressed.
2 PUSH BUTTONS LOGIC
One start opens, one pedestrian start closes. In opening the closing will not be accepted. In closing a start command reopens, a
pedestrian start command (closes) will be ignored.
The SLIM motor has no limit switches and works only with Encoder. For the stroke learning it is necessary that the motor reaches the
mechanical stops. Learning provides a CLOSE-OPEN-CLOSE cycle with automatic detection of the mechanical stops. During normal cycle
the motor will stop at about 1 cm from the mechanical stop. This space will be regulated through the motor release parameter (meu 82).
Attention:
In case of the STOP command, power failure or obstacle detection, the motor will perform a closing maneuver at low speed up to the
mechanical stop in closing, to retrieve the position.
PROGRAMMING SLIM MOTOR WITHOUT LIMIT SWITCH
English