Samil Power SP-SR-V5-EN Manual de usuario

SolarRiver PV Grid-tied Inverter
Product Manual
TM
SP-SR-V5-EN
Samil Power
Expert for PV Grid-tied Inverters


1
The copyright of this manual belongs to Samil Power Co., Ltd. Any corporation or individual
should not plagiarize, partially copy or fully copy it (including software, etc.) , and no reproduc-
tion or distribution of it in any form or by any means. All rights reserved.Samil Power reserves
the right of final interpretation. This information is subject to changes without notice.
Copyright Declaration

2

Contents
1 NOTES ON THIS MANUAL .......................................................................................................... 5
1.1 SCOPE OF VALIDITY .................................................................................................................................... 5
1.2 TARGET GROUP........................................................................................................................................... 5
1.3 SYMBOLS USED .......................................................................................................................................... 5
2 SAFETY..........................................................................................................................................6
2.1 APPROPRIATE USAGE .................................................................................................................................. 6
2.2 IMPORTANT SAFETY INSTRUCTIONS ............................................................................................................ 6
2.3 EXPLANATION OF SYMBOLS ........................................................................................................................ 7
3 INTRODUCTION ...........................................................................................................................9
3.1 BASIC FEATURES..........................................................................................................................................9
3.2 ELECTRICAL BLOCK DIAGRAM .................................................................................................................... 9
3.3 DIMENSION AND WEIGHT.......................................................................................................................... 10
4 TECHNICAL DATA ......................................................................................................................11
4.1 INPUT (DC)................................................................................................................................................11
4.2 OUTPUT (AC) ............................................................................................................................................12
4.3 EFFICIENCY,SAFETY AND PROTECTION .................................................................................................... 12
4.4 GENERAL DATA..........................................................................................................................................13
5 FUNCTION ...................................................................................................................................13
6 INSTALLATION ...........................................................................................................................15
6.1 PACKAGING................................................................................................................................................15
6.2 INSTALLATION PRECAUTION...................................................................................................................... 16
6.3 PREPARATION.............................................................................................................................................17
6.4 INSTALLATION STEPS ................................................................................................................................ 17
6.5 CONNECTIONS OF THE PV POWER SYSTEM................................................................................................ 18
6.6 RUN THE INVERTER ....................................................................................................................................23
3

4
7 OPERATION METHOD ............................................................................................................... 24
7.1 CONTROL PANEL ........................................................................................................................................24
7.2 LCD FUNCTION .........................................................................................................................................25
7.3 LCD INFORMATION....................................................................................................................................27
8 COMMUNICATION AND MONITORING ................................................................................... 29
8.1 COMMUNICATION INTERFACE .................................................................................................................... 29
8.2 COMMUNICATION.......................................................................................................................................29
9 TROUBLESHOOTING ................................................................................................................. 32
9.1 TROUBLESHOOTING ................................................................................................................................... 32
9.2 ROUTINE MAINTENANCE ........................................................................................................................... 34
10 DECOMMISSIONING ................................................................................................................ 35
10.1 DISMANTLING THE INVERTER .................................................................................................................. 35
10.2 PACKAGING...............................................................................................................................................35
10.3 STORAGE ..................................................................................................................................................35
10.4 DISPOSAL..................................................................................................................................................35
11 CONTACT SAMIL POWER ........................................................................................................ 36

5
1 Notes on This Manual
Notes on This Manual
This manual is an integral part of the inverter, Please read the product manual carefully
before installation, operation or maintenance. Keep this product manual for future reference.
1.1 Scope of Validity
This installation guide describes the assembly, installation, commissioning, maintenance and
failure search of the following Samil Power SolarRiver Series inverters.
SR1K5TLA1 SR2K2TLA1 SR2K8TLA1
SR3K3TLA1 SR4K4TLA1 SR4K4TLA1-PT SR5KTLA1
Store this manual where it will be accessible at all times.
1.2 Target Group
This manual is for qualified personnel. The tasks described in this manual must only be performed
by qualified personnel.
1.3 Symbols Used
The following types of safety instructions and general information appear in this document as
described below.
Danger !
Danger indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
Warning !
Warning indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
Caution !
Caution indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
Note !
Note provides tips that are valuable for the optimal operation of your
product.

6
2 Safety
Safety
2.1 Appropriate Usage
The SolarRiver Series is a PV inverter which converts the DC current of a PV generator into AC
current and feeds it into the public grid.
Figure 1 PV Grid-tied System
2.2 Important Safety Instructions
Danger !
Danger to life due to high voltages in the inverter!
Caution !
Danger of burn injuries due to hot enclosure parts!
Caution !
Possible damage to health as a result of the effects of radiation!
Note !
GridPV Module Grid-tied Inverter
• All work on the inverter must be carried out by qualified personnel only.
• The appliance is not to be used by children or persons with reduced physical
sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction.
• Children should be supervised to ensure that they do not play with the
appliance.
During operation, the upper lid of the enclosure and the enclosure body may
become hot.
• Only touch the lower enclosure lid during operation.
• Do not stay closer than 20 cm to the inverter for any length of time.
Grounding the PV generator. Comply with the local requirements for
grounding the PV modules and the PV generator. Samil Power recommends
connecting the generator frame and other electrically conductive surfaces in a
manner which ensures continuous conduction and ground these in order to have
optimal protection of the system and personnel.

7
Warning !
Safety
2.3 Explanation of Symbols
●Symbols on the Inverter
Symbol Explanation
Danger of high voltages
Danger to life due to high voltages in the inverter!
Caution, risk of electric shock!
Only authorized personnel is allowed to set the DIP switch.
●Symbols on the Type Label
Symbol Explanation
●Important Safety Instructions
This section gives an explanation of all the symbols shown on the inverter and on the type label.
Danger to life due to high voltages in the inverter!
There is residual voltage in the inverter. The inverter requires
5 minutes to discharge.
• Wait 5 minutes before you open the upper lid or the DC lid.
Beware of hot surface.
The inverter can become hot during operation. Avoid contact during
operation.
5min
CE mark.
The inverter complies with the requirements of the applicable
CE guidelines.
When using the product, please do remember the below information to avoid the fire, lightning
or other personal injury:
Ensure input DC voltage ≤ Max. DC voltage .Over voltage may
cause permanent damage to inverter or other losses, which will not
be included in warranty! This chapter contains important safety and
operating instructions. Read and keep this Operation Guide for
future reference.

8
Safety
Warning !
Authorized service personnel must disconnect both AC and DC power
from the SolarRiver Series inverter before attempting any maintenance
or cleaning or working on any circuits connected to the SolarRiver
Series inverter.
● Before using the SolarRiver Series inverter, read all instructions and cautionary markings on
the SolarRiver Series inverter, and all appropriate sections of this guide.
● Use only attachments recommended or sold by Samil Power. Doing otherwise may result in a
risk of fire, electric shock, or injury to persons.
● To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and
that wire is not undersized. Do not operate the SolarRiver Series inverter with damaged or
substandard wiring.
● Do not disassemble the SolarRiver Series inverter. It contains no user-serviceable parts. See
Warranty for instructions on obtaining service. Attempting to service the SolarRiver Series
inverter yourself may result in a risk of electric shock or fire and will void your warranty.
● To reduce the risk of electric shock,authorized service personnel must disconnect both AC and
DC power from the SolarRiver Series inverter before attempting any maintenance or cleaning
or working on any circuits connected to the SolarRiver Series inverter. Turning off controls will
not reduce this risk.
● Keep away from flammable, explosive materials to avoid fire disaster.
● The installation place should be away from humid or corrosive substance.
● To avoid electric shock accident, please do not disassemble the inverter because there are
high-voltage capacitances installed inside the inverter. Fatal High-voltage will remain in the
inverter after its disconnection with grid after 5 minutes.
● To reduce the chance of short-circuits, authorized service personnel must use insulated tools
when installing or working with this equipment.
Tabla de contenidos
Otros manuales de Inversor de Samil Power

Samil Power
Samil Power SolarLake 5500TL-PM Manual de usuario

Samil Power
Samil Power SolarRiver 3400TL-D Manual de usuario

Samil Power
Samil Power SolarLake 5500TL-PM Manual de usuario

Samil Power
Samil Power SolarRiver 3400TL-D Manual de usuario

Samil Power
Samil Power SolarRiver 4500TL-G3 Manual de usuario

Samil Power
Samil Power SolarLake 5500TL-PM Manual de usuario

Samil Power
Samil Power SolarRiver 1100TL Manual del operador

Samil Power
Samil Power SolarRiver 1100TL-S Manual de usuario

Samil Power
Samil Power SolarLake 12000TL-PM Manual de usuario

Samil Power
Samil Power SolarRiver 3400TL-D Manual de usuario