10 | EN RIS 1200-3500 H EKO 3.0 v2021.1
4.3. TECHNICAL DATA
RIS EKO 3.0 1200 HE 1200 HW
Exhaust air fan
phase/voltage [50 Hz/VAC] 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,38/2,5 0,38/2,5
speed [min-1] 3370 3370
control input [VDC] 0-10 0-10
protection class IP54 IP54
Supply air fan
phase/voltage [50 Hz/VAC] 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,38/2,5 0,38/2,5
speed [min-1] 3370 3370
control input [VDC] 0-10 0-10
protection class IP54 IP54
Integrated electrical heater [kW] 2 -
7RWDOSRZHUFXUUHQWFRQVXPSWLRQ [kW/A] 2,76/13,7 0,76/5
Automatic control integrated PRV PRV
,QVXODWLRQRIZDOOV [mm] 50 50
([KDXVWDLU¿OWHUFODVVGLPHQVLRQV/[:[+ [mm] MPL 650x415x46 ePM10-55 MPL 650x415x46 ePM10-55
6XSSO\DLU¿OWHUFODVVGLPHQVLRQV/[:[+ [mm] MPL 650x415x46 ePM1-70 MPL 650x415x46 ePM1-70
Device protection class IP34 IP34
RIS EKO 3.0 1900 HE 1900 HW 2200 HE 2200 HW
Exhaust air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,47/2,04 0,47/2,04 0,715/3,1 0,715/3,1
speed [min-1] 2530 2530 2800 2800
control input [VDC] 0-10 0-10 0-10 0-10
protection class IP54 IP54 IP54 IP54
Supply air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,47/2,04 0,47/2,04 0,715/3,1 0,715/3,1
speed [min-1] 2530 2530 2800 2800
control input [VDC] 0-10 0-10 0-10 0-10
protection class IP54 IP54 IP54 IP54
Integrated electrical heater [kW] 3 - 3 -
7RWDOSRZHUFXUUHQWFRQVXPSWLRQ [kW/A] 3,94/17,08 0,94/4,08 4,43/19,2 1,43/6,2
Automatic control integrated PRV PRV PRV PRV
,QVXODWLRQRIZDOOV [mm] 50 50 50 50
([KDXVWDLU¿OWHUFODVVGLPHQVLRQV/[:[+ [mm] MPL 692x520x46
ePM10-55
MPL 692x520x46
ePM10-55
MPL 692x520x46
ePM10-55
MPL 692x520x46
ePM10-55
6XSSO\DLU¿OWHUFODVVGLPHQVLRQV/[:[+ [mm] MPL 692x520x46
ePM1-70
MPL 692x520x46
ePM1-70
MPL 692x520x46
ePM1-70
MPL 692x520x46
ePM1-70
Device protection class IP34 IP34 IP34 IP34