Operating Instruction Manual
High-performance Vector Inverter

Contents
018
018
019
019
020
020
021
021
022
023
3 Operation Panel and Operation Method
3.1 Operation Panel Keys
3.2 LED and Indicator Light Description
3.3 Monitoring Parameter Display
3.4 Run Status Parameter Display
3.5 Malfunction Alarm Display
3.6 Function Code Editing Display
3.7 Monitoring Parameter
3.8 Function Code Setting
3.9 User Password Setting and Function Code Edit
007
008
008
008
009
011
012
012
014
016
017
017
2 Installation and Wiring
2.1 Operation Environment
2.2 Installing Direction and Space
2.3 Appearance and Dimension of Keypad
2.4 Whole Structure
2.5 Basic Running Wiring
2.6 Main Circuit Terminal Wiring
2.7 Schematic of The Main Circuit Terminal
2.8 Control Loop Terminal Function Table
2.9 Dial Switch
2.10 Wiring Notices
2.11 Spare Circuit
001
002
003
0011 Safety Precautions and Product Model
1.1 Safety Precautions
1.2 VFD Series Type
1.3 Technical Index and Specication

025
025
029
076
115
119
125
131
132
137
138
140
4 Function Parameter Table and Description
4.0 Monitoring Parameter Group and Fault Record
4.1 Function Code
4.2 Detailed Function Description
F8 Process PID Parameter
F9 Programmable Operation Parameter
FA Protection Parameter
FB Communication Parameter
FC Advance Function Parameter and Performance Parameter
FD Pump Use Parameter
FE
Panel Function Setting and Parameter Management (PD group reserved)
FF Factory Parameter
160
160
164
6 Troubleshooting
6.1 Fault information and Troubleshooting
6.2 Abnormal Phenomena Solution
145
145
145
155
156
157
157
158
158
159
5 Communication Protocol
5.1 RTU mode and format
5.2 Register Address and Function Code
5.3 Functions of other Register Address
5.4 Fault Code
5.5 Pre-alarm Code of the Driver
5.6 Control Command Format (see function code 06H example)
5.7 Parameter Attribute
5.8 Error Code from Slave Response of Abnormal Information
5.9 Communication Address of all Parameters
166
166
166
7 Maintenance
7.1 Routine Maintenance
7.2 Periodic Maintenance
168
168
170
171
Appendix
Appendix 1: Parameters for Photovoltaic Pumps Special Use
Appendix 2:
600 Series Guide for Rapid Debugging of Constant-pressure Water Supply
Appendix 3: 610 Series Guide for Rapid Debugging of CNC Machine

001
1 Safety Precautions and Product Model
1.1 Safety Precautions
◇ Do not install this equipment in an explosive gas atmosphere, or there will be explosion
hazards.
◇ Only qualied individuals should proceed with wiring, or there will be electric shock hazards.
Do not conduct any wiring during the system power on to avoid the electric shock.
◇ Do not touch control terminals, internal circuit board and its components, or there will be
electric shock hazard.
◇ Earth terminal must be exactly grounded when using inverter. Grounding must be conrmed
with the national electric safety regulation and other electric code.
◇ After power o, do not touch internal circuit board or any parts inside within 5 minutes after
keypad display went o. Any internal operation must be after making sure of discharge o
with instrument checking to avoid the electric shock.
◇ Do not connect AC power to output terminal (U, V, W) of inverter. The only terminal the AC
power allowed to be connected is R, S, T (or Ll, L2 single-phrase source inverter).
◇ Static electricity on human body can damage MOS device. Do not touch PCB and IGBT
without anti-static measure.
◇ Do not lose screws, spacers and other metallic foreign bodies inside the driver to avoid re
hazard and driver damage.
◇ Do not connect 220V AC power to internal control terminal of the driver, or there will be
serious damage to the driver.
◇ If overcurrent protection occurs aer start the driver, conrm again the external wiring and
then power on and run the driver.
◇ Do not switch off the power to stop the driver. Cut off power source after the motor stops
running.
◇ Do not install the driver in places with direct sunlight.

002
1.2 VFD Series Type
Input Voltage Rated
Power(KW)
Rated Output
Current (A)
Adapted
Motor
Single Phase
230V±15%
0.75 5 0.75
1.5 7 1.5
2.2 10 2.2
Three Phase
380V±15%
0.75 2.5 0.75
1.5 3.7 1.5
2.2 5 2.2
4.0/5.5 9.0/13 4.0/5.5
5.5/7.5 13/17 5.5/7.5
7.5/11.0 17/25 7.5/11.0
11.0/15.0 25/32 11.0/15.0
15.0/18.5 32/37 15.0/18.5
18.5/22.0 37/45 18.5/22.0
22.0/30.0 45/60 22.0/30.0
30.0/37.0 60/75 30.0/37.0
37.0/45.0 75/90 37.0/45.0
45.0/55.0 90/110 45.0/55.0
55.0/75.0 110/150 55.0/75.0
75.0/90.0 150/176 75.0/90.0
90.0/110.0 176/210 90.0/110.0
110.0/132.0 210/250 110.0/132.0
132.0/160.0 250/300 132.0/160.0
160.0/185.0 300/340 160.0/185.0
185.0/200.0 340/380 185.0/200.0

003
1.2 VFD Series Type
Input Voltage Rated
Power(KW)
Rated Output
Current (A)
Adapted
Motor
Three Phase
380V±15%
200.0/220.0 380/415 200.0/220.0
220.0/250.0 415/470 220.0/250.0
250.0/280.0 470/520 250.0/280.0
280.0/315.0 520/600 280.0/315.0
315.0/350.0 600/640 315.0/350.0
350 640 350
400 690 400
500 860 500
1.3 Technical Index and Specication
Input
Rated Voltage,
Frequency
3-phase (4T#series) 380V;50/60HZ
1-phase (2S#series) 220V;50/60HZ
Allowed
Voltage Range
3-phase (4T#series) 320V ~ 460V
1-phase (2S#series) 160V ~ 260V
Output
Voltage 4T#series; 0 ~ 460V
2S#series; 0 ~ 260V
Frequency Low frequency mode: 0 ~ 300HZ ;
High frequency mode: 0 ~ 3000HZ
Overload
Capacity
G type: 110% for long-term, 150% for 1 min, 180% for 5s
P type: 105% for long-term, 120% for 1 min, 150% for 1s
Control Mode V/F control, advanced V/F control, V/F separation control,
electric current vector control
Control
Character
Frequency
Setting
Resolution
Analog Input 0.1% of maximum output frequency
Digital Setting 0.01 Hz

004
1.3 Technical Index and Specication
Control
Character
Frequency
Precision
Analog Input Within 0.2% of maximum output frequency
Digital Setting Within 0.01% of set output frequency
V/F Control
V/F Curve (voltage
frequency character)
Reference frequency setting 5 ~ 600 Hz,
multipoint V/F curve setting, or xed curve
of constant torque, low decreasing torque 1,
low decreasing torque 2, square torque
Torque
Compensation
Manual setting: 0.0 ~ 30% of rated output
Automatic compensation: according to
output current and motor parameter
Automatic
Current-Iimiting
and Voltage-Iimiting
During acceleration, deceleration or steady
running, detect automatically the current
and voltage of motor stator, and control it
within bounds based on unique algorithm,
minimize fault-trip chance
Senseless
Vector
Control
Voltage Frequency
Character
Adjust pressure/frequency ratio according
to motor parameter and unique algorithm
Torque Character
Starting torque:
3.0 Hz 150% rated torque (VF control)
0.5 Hz 180% rated torque (SVC, FVC)
0.05 Hz 180% rated torque (VC)
Operating speed precision in steady state:
≤ +0.5% rated synchronous speed
Torque response:
≤ 50ms VC, SVC, FVC ≤ 20ms
Motor Parameter
Self-measurement
Being able to detect parameter
automatically under static state and
dynamic state of motor, thus guarantee an
optimum control.
Current and Voltage
Restrain
Current closed-loop control, free from
current impact, perfect restrain function of
overcurrent and overvoltage
Undervoltage
Restrain
during
Running
Specially for users with a low or unsteady voltage power grid: even
lower than the allowable voltage range, the system can maintain
the longest possible operating time based on its unique algorithm
and residual energy allocation strategy